Literature DB >> 19828337

Three-dimensional imaging core laboratory of the endovascular aneurysm repair trials: validation of methodology.

T R Wyss1, F Dick, A England, L C Brown, A D Rodway, R M Greenhalgh.   

Abstract

OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory.
METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length.
RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes.
CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.

Entities:  

Mesh:

Year:  2009        PMID: 19828337     DOI: 10.1016/j.ejvs.2009.09.007

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  3 in total

1.  Inferior Mid-term Durability with Comparable Survival for Younger Patients Undergoing Elective Endovascular Infrarenal versus Open Abdominal Aortic Aneurysm Repair.

Authors:  Katherine M Reitz; Nathan L Liang; Bowen Xie; Michel Makaroun; Edith Tzeng
Journal:  Ann Vasc Surg       Date:  2019-10-18       Impact factor: 1.466

2.  Comparison of ABC/2 estimation and a volumetric computerized method for measurement of meningiomas using magnetic resonance imaging.

Authors:  Charles F Opalak; Matthew Parry; Andrew K Rock; Adam P Sima; Matthew T Carr; Vyshak Chandra; Kathryn G Workman; Aravind Somasundaram; William C Broaddus
Journal:  J Neurooncol       Date:  2019-08-10       Impact factor: 4.130

3.  Endovascular Abdominal Aortic Aneurysm Repair - Patient Selection and Long-term Outcome Expectations - Current Challenges in 2013.

Authors:  Regula S von Allmen; Florian Dick; Thomas R Wyss; Roger M Greenhalgh
Journal:  Interv Cardiol       Date:  2013-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.