Literature DB >> 19828287

Velocity vector imaging in the measurement of left ventricular twist mechanics: head-to-head one way comparison between speckle tracking echocardiography and velocity vector imaging.

Dae-Hee Kim1, Hyung-Kwan Kim, Min-Kyung Kim, Sung-A Chang, Yong-Jin Kim, Myung-A Kim, Dae-Won Sohn, Byung-Hee Oh, Young-Bae Park.   

Abstract

BACKGROUND: Velocity vector imaging (VVI) is based on myocardial feature tracking, which incorporates speckle and endocardial border tracking and allows myocardial strains, strain rates, and velocities to be quantified. However, the accuracies of VVI-derived left ventricular rotation-associated values have not been validated, and the aim of this study was thus to perform a head-to-head comparison of twist-related values determined by VVI and speckle-tracking echocardiography (STE).
METHODS: Thirty-five patients with a wide spectrum of cardiac pathologies and 19 healthy subjects (a total of 54 subjects) were enrolled. Apical and basal short-axis images were obtained using GE Vivid 7 scanners at frame rates of 80 to 100 frames/s. Left ventricular rotation-related parameters were first obtained using EchoPAC version 7.0.1. For comparison purposes, the same basal and apical short-axis images were converted into uncompressed Digital Imaging and Communications in Medicine format and subsequently analyzed using Syngo version 3.0, which uses a VVI tracking algorithm.
RESULTS: Basal and apical peak rotation and peak twist determined using STE and VVI were well correlated (r = 0.80, P < .001, r = 0.87, P < .001, and r = 0.90, P < .001, respectively). With regard to rotation velocities, peak rotation and derotation velocities were moderately correlated at the basal (r = 0.70, P < .001, and r = 0.72, P < .001, respectively) and apical (r = 0.66, P < .001, and r = 0.51, P < .001, respectively) levels. Furthermore, twist and untwist velocities were moderately correlated between the two methods. However, the timings of peak rotation and derotation velocities and twist and untwist velocities were only weakly correlated at the basal and apical levels.
CONCLUSIONS: VVI is a feasible modality for assessing twist-related parameters. Although VVI agreed well with STE for most of the rotation-related parameters, poor concordance was found between the two methods for a few parameters. It is hypothesized that this discrepancy originates from the different tracking algorithms used. The findings indicate that caution should be exercised when interpreting or comparing twist-related parameters obtained using different echocardiographic devices with proprietary image analyzers.

Entities:  

Mesh:

Year:  2009        PMID: 19828287     DOI: 10.1016/j.echo.2009.09.002

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  12 in total

1.  Role of left ventricular untwisting in diastolic dysfunction after long duration exercise.

Authors:  Stéphane Nottin; Arnaud Ménétrier; Thomas Rupp; Alain Boussuges; Nicolas Tordi
Journal:  Eur J Appl Physiol       Date:  2011-05-21       Impact factor: 3.078

2.  Assessment of mitral annular and velocity vector imaging in acute myopericarditis.

Authors:  Matthew Lynch; Robert O'Donnell; Neal L Weintraub; Angel López-Candales
Journal:  Echocardiography       Date:  2013-07-01       Impact factor: 1.724

3.  Circumferential and longitudinal ventricular strain in the normal human fetus.

Authors:  Tetsuko Ishii; Doff B McElhinney; David M Harrild; Edward N Marcus; David J Sahn; Uyen Truong; Wayne Tworetzky
Journal:  J Am Soc Echocardiogr       Date:  2011-10-26       Impact factor: 5.251

Review 4.  Perioperative assessment of myocardial deformation.

Authors:  Andra E Duncan; Andrej Alfirevic; Daniel I Sessler; Zoran B Popovic; James D Thomas
Journal:  Anesth Analg       Date:  2014-03       Impact factor: 5.108

5.  Cardiac mechanics in patients with human immunodeficiency virus: a study of systolic myocardial deformation in children and young adults.

Authors:  Ghassan Al-Naami; Fuad Kiblawi; Helen Kest; Ayman Hamdan; Dorothy Myridakis
Journal:  Pediatr Cardiol       Date:  2014-04-20       Impact factor: 1.655

6.  Serial echocardiography using tissue Doppler and speckle tracking imaging to monitor right ventricular failure before and after left ventricular assist device surgery.

Authors:  Tomoko Sugiyama Kato; Jeffrey Jiang; Paul Christian Schulze; Ulrich Jorde; Nir Uriel; Shuichi Kitada; Hiroo Takayama; Yoshifumi Naka; Donna Mancini; Linda Gillam; Shunichi Homma; Maryjane Farr
Journal:  JACC Heart Fail       Date:  2013-06-03       Impact factor: 12.035

Review 7.  Heart disease and left ventricular rotation - a systematic review and quantitative summary.

Authors:  Aaron A Phillips; Anita T Cote; Shannon S D Bredin; Darren E R Warburton
Journal:  BMC Cardiovasc Disord       Date:  2012-06-24       Impact factor: 2.298

8.  Noninvasive assessment of myocardial mechanics of the left ventricle in rabbits using velocity vector imaging.

Authors:  Jia Zhou; Da-Rong Pu; Lei-Qi Tian; Hai Tong; Hong-Yu Liu; Yan Tang; Qi-Chang Zhou
Journal:  Med Sci Monit Basic Res       Date:  2015-05-28

Review 9.  Multimodality Imaging in Congenital Heart Disease: an Update.

Authors:  Uyen T Truong; Shelby Kutty; Craig S Broberg; David J Sahn
Journal:  Curr Cardiovasc Imaging Rep       Date:  2012

10.  Role of Quantitative Wall Motion Analysis in Patients with Acute Chest Pain at Emergency Department.

Authors:  Kyung-Hee Kim; Sang-Hoon Na; Jin-Sik Park
Journal:  J Cardiovasc Ultrasound       Date:  2017-03-27
View more