Literature DB >> 19826813

Immediate recovery room radiographs after primary total knee arthroplasty-why do we keep doing them?

Yona Kosashvili1, Mansour Alvi, Ian P Mayne, Oleg Safir, Alan Gross, David Backstein.   

Abstract

Recovery room radiographs (RRR) are routinely performed after total knee arthroplasty (TKA). This study investigates the utility of these radiographs. Twenty four arthroplasty surgeons were surveyed to rank the value of RRRs. Since RRRs were primarily valued for educational purposes, we examined the ability of 49 orthopaedic trainees to determine the coronal alignment of TKA performed in cadaveric specimens based on these radiographs in neutral, 10° internal and external rotations. Surgeons rated the quality of the RRRs to be significantly lower than the radiographs taken in the radiology suite (5.5 ± 2.5 versus 8.9 ± 0.9, p < 0.0001). Of an estimated 65,910 TKAs performed by these surgeons, only eight cases (0.01%) required same day revision based on the RRR. Neutral alignment was significantly more accurately (p < 0.0001) interpreted than valgus or varus (69.4% versus 42.9% and 16.3%, respectively). Surprisingly, internal rotation of the limb significantly improved interpretation of both varus (from 16.3% to 40.8%, p = 0.014) and valgus (from 42.9% to 63.3%, p = 0.048). Increased level of orthopaedic training did not significantly affect the accuracy of interpretation (p = 0.46). Interpretation of RRRs for coronal malalignment is inaccurate and has a limited educational value.

Mesh:

Year:  2009        PMID: 19826813      PMCID: PMC2989086          DOI: 10.1007/s00264-009-0888-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  20 in total

1.  Underestimation of varus angulation in knees with flexion deformity.

Authors:  Tomihisa Koshino; Masanobu Takeyama; Lei Sheng Jiang; Takuji Yoshida; Tomoyuki Saito
Journal:  Knee       Date:  2002-12       Impact factor: 2.199

2.  Coronal alignment after total knee replacement.

Authors:  R S Jeffery; R W Morris; R A Denham
Journal:  J Bone Joint Surg Br       Date:  1991-09

3.  Postoperative radiographs after total knee arthroplasty: a cost-containment strategy.

Authors:  J T Moskal; D R Diduch
Journal:  Am J Knee Surg       Date:  1998

4.  Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties.

Authors:  J H Lonner; M T Laird; S A Stuchin
Journal:  Clin Orthop Relat Res       Date:  1996-10       Impact factor: 4.176

5.  Radiographic analysis of the axial alignment of the lower extremity.

Authors:  J R Moreland; L W Bassett; G J Hanker
Journal:  J Bone Joint Surg Am       Date:  1987-06       Impact factor: 5.284

6.  Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty.

Authors:  M H Oswald; R P Jakob; E Schneider; H M Hoogewoud
Journal:  J Arthroplasty       Date:  1993-08       Impact factor: 4.757

7.  Ionising radiation and the orthopaedic patient.

Authors:  D J Stoker
Journal:  J Bone Joint Surg Br       Date:  1993-01

Review 8.  Knowledge of results and motor learning: a review and critical reappraisal.

Authors:  A W Salmoni; R A Schmidt; C B Walter
Journal:  Psychol Bull       Date:  1984-05       Impact factor: 17.737

9.  Radiographic cost reduction strategy in total joint arthroplasty. A prospective analysis.

Authors:  P A Ververeli; J L Masonis; R E Booth; W J Hozack; R H Rothman
Journal:  J Arthroplasty       Date:  1996-04       Impact factor: 4.757

10.  Cost-effectiveness of immediate postoperative radiographs after uncomplicated total knee arthroplasty: a retrospective and prospective study of 750 patients.

Authors:  D Glaser; P Lotke
Journal:  J Arthroplasty       Date:  2000-06       Impact factor: 4.757

View more
  2 in total

Review 1.  Influence of axial limb rotation on radiographic lower limb alignment: a systematic review.

Authors:  Marc-Daniel Ahrend; Heiko Baumgartner; Christoph Ihle; Tina Histing; Steffen Schröter; Felix Finger
Journal:  Arch Orthop Trauma Surg       Date:  2021-10-01       Impact factor: 2.928

2.  Immediate Postoperative Portable Radiograph After Total Knee Replacements: A Necessity or a Burden?

Authors:  Abdulla Aljawder; Dana Alomran; Mohammed Alayyoub; Fahad Alkhalifa
Journal:  Open Orthop J       Date:  2018-05-31
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.