Literature DB >> 19826204

Tumour tracking with scanned proton beams: assessing the accuracy and practicalities.

S van de Water1, R Kreuger, S Zenklusen, E Hug, A J Lomax.   

Abstract

The potential of tumour tracking for active spot-scanned proton therapy was assessed. Using a 4D-dose calculation and simulated target motion, a tumour tracking algorithm has been implemented and applied to a simple target volume in both homogenous and heterogeneous in silico phantoms. For tracking and retracking (a hybrid solution combining tumour tracking and rescanning), three tracking modes were analysed: 'no tracking' (uncorrected irradiation of a moving target), 'perfect tracking' (no time delays and exact knowledge of target position) and 'imperfect tracking' (simulated time delays or position prediction errors). For all plans, dose homogeneity in the target volume was assessed as the difference between D5 and D95 in the CTV. For the homogeneous phantom, perfect tracking could retrieve nominal dose homogeneity for all motion phases and amplitudes while severe deterioration of treatment outcomes was found for imperfect tracking. The use of retracking reduced the sensitivity to position errors significantly in the homogeneous phantom. In the heterogeneous phantoms (simulated rib proximal to target), the nominal dose homogeneity could not be obtained with perfect tracking. Adjustments in pencil beam positions could cause pencil beams to deform under the influence of the bone, resulting in loss of dose homogeneity. As retracking was not capable of reducing these effects, rescanning provided the best treatment outcomes for moving heterogeneous targets in this study.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19826204     DOI: 10.1088/0031-9155/54/21/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

Review 1.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

2.  Dosimetric feasibility of real-time MRI-guided proton therapy.

Authors:  M Moteabbed; J Schuemann; H Paganetti
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

3.  Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors.

Authors:  John Gordon Eley; Wayne David Newhauser; Daniel Richter; Robert Lüchtenborg; Nami Saito; Christoph Bert
Journal:  Phys Med Biol       Date:  2015-02-04       Impact factor: 3.609

4.  4D optimization of scanned ion beam tracking therapy for moving tumors.

Authors:  John Gordon Eley; Wayne David Newhauser; Robert Lüchtenborg; Christian Graeff; Christoph Bert
Journal:  Phys Med Biol       Date:  2014-06-03       Impact factor: 3.609

Review 5.  Advances in 4D treatment planning for scanned particle beam therapy - report of dedicated workshops.

Authors:  Christoph Bert; Christian Graeff; Marco Riboldi; Simeon Nill; Guido Baroni; Antje-Christin Knopf
Journal:  Technol Cancer Res Treat       Date:  2013-12-17

Review 6.  Particle therapy for non-small cell lung tumors: where do we stand? A systematic review of the literature.

Authors:  Krista C J Wink; Erik Roelofs; Timothy Solberg; Liyong Lin; Charles B Simone; Annika Jakobi; Christian Richter; Philippe Lambin; Esther G C Troost
Journal:  Front Oncol       Date:  2014-10-29       Impact factor: 6.244

7.  Optimization of motion management parameters in a synchrotron-based spot scanning system.

Authors:  Jedediah E Johnson; Michael G Herman; Jon J Kruse
Journal:  J Appl Clin Med Phys       Date:  2019-09       Impact factor: 2.102

8.  The potential of Gantry beamline large momentum acceptance for real time tumour tracking in pencil beam scanning proton therapy.

Authors:  Giovanni Fattori; Ye Zhang; David Meer; Damien Charles Weber; Antony John Lomax; Sairos Safai
Journal:  Sci Rep       Date:  2020-09-18       Impact factor: 4.379

9.  Investigation of inter-fraction target motion variations in the context of pencil beam scanned proton therapy in non-small cell lung cancer patients.

Authors:  Lydia A den Otter; Renske M Anakotta; Menkedina Weessies; Catharina T G Roos; Nanna M Sijtsema; Christina T Muijs; Margriet Dieters; Robin Wijsman; Esther G C Troost; Christian Richter; Arturs Meijers; Johannes A Langendijk; Stefan Both; Antje-Christin Knopf
Journal:  Med Phys       Date:  2020-07-09       Impact factor: 4.071

Review 10.  Management of Motion and Anatomical Variations in Charged Particle Therapy: Past, Present, and Into the Future.

Authors:  Julia M Pakela; Antje Knopf; Lei Dong; Antoni Rucinski; Wei Zou
Journal:  Front Oncol       Date:  2022-03-09       Impact factor: 6.244

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.