Literature DB >> 19823981

Physical modeling of pulse artefact sources in simultaneous EEG/fMRI.

Winston X Yan1, Karen J Mullinger, Gerda B Geirsdottir, Richard Bowtell.   

Abstract

The collection of electroencephalography (EEG) data during simultaneous functional magnetic resonance imaging (fMRI) is impeded by large artefacts in the EEG recordings, with the pulse artefact (PA) being particularly challenging because of its persistence even after application of artefact correction algorithms. Despite several possible causes of the PA having been hypothesized, few studies have rigorously quantified the contributions from the different putative sources. This article presents analytic expressions and simulations describing two possible sources of the PA corresponding to different movements in the strong static field of the MR scanner: cardiac-pulse-driven head rotation and blood-flow-induced Hall voltages. Models of head rotation about a left-right axis and flow in a deep artery running in the anterior-posterior direction reproduced properties of the PA including the left/right spatial variation of polarity. Of these two sources, head rotation was shown to be the most likely source of the PA with simulated magnitudes of >200 muV being generated at 3 T, similar to the in vivo PA magnitudes, for an angular velocity of just 0.5 degrees /s. Smaller artefact voltages of less than 10 muV were calculated for flow in a model artery with physical characteristics similar to the internal carotid artery. A deeper physical understanding of the PA is a key step in working toward production of higher fidelity EEG/fMRI data: analytic expressions for the artefact voltages can guide a redesign of the wiring layout on EEG caps to minimize intrinsic artefact pickup, while simulated artefact maps could be incorporated into selective filters. Copyright 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19823981      PMCID: PMC6870628          DOI: 10.1002/hbm.20891

Source DB:  PubMed          Journal:  Hum Brain Mapp        ISSN: 1065-9471            Impact factor:   5.038


  23 in total

1.  Electric potential produced by a dipole in a homogeneous conducting sphere.

Authors:  D Yao
Journal:  IEEE Trans Biomed Eng       Date:  2000-07       Impact factor: 4.538

2.  Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis.

Authors:  D Mantini; M G Perrucci; S Cugini; A Ferretti; G L Romani; C Del Gratta
Journal:  Neuroimage       Date:  2006-11-16       Impact factor: 6.556

3.  An independent component analysis-based approach on ballistocardiogram artifact removing.

Authors:  Ennio Briselli; Girolamo Garreffa; Luigi Bianchi; Marta Bianciardi; Emiliano Macaluso; Manuel Abbafati; Maria Grazia Marciani; Bruno Maraviglia
Journal:  Magn Reson Imaging       Date:  2006-03-20       Impact factor: 2.546

4.  Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis.

Authors:  Wakako Nakamura; Kimitaka Anami; Takeyuki Mori; Osamu Saitoh; Andrzej Cichocki; Shun-ichi Amari
Journal:  IEEE Trans Biomed Eng       Date:  2006-07       Impact factor: 4.538

5.  Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging.

Authors:  Roland Bammer; Thomas A Hope; Murat Aksoy; Marcus T Alley
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

6.  Understanding gradient artefacts in simultaneous EEG/fMRI.

Authors:  Winston X Yan; Karen J Mullinger; Matt J Brookes; Richard Bowtell
Journal:  Neuroimage       Date:  2009-06       Impact factor: 6.556

7.  Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction.

Authors:  P J Allen; G Polizzi; K Krakow; D R Fish; L Lemieux
Journal:  Neuroimage       Date:  1998-10       Impact factor: 6.556

8.  A fast method to compute surface potentials generated by dipoles within multilayer anisotropic spheres.

Authors:  Z Zhang
Journal:  Phys Med Biol       Date:  1995-03       Impact factor: 3.609

9.  Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings.

Authors:  Richard A J Masterton; David F Abbott; Steven W Fleming; Graeme D Jackson
Journal:  Neuroimage       Date:  2007-05-18       Impact factor: 6.556

10.  Electric fields induced in the human body by time-varying magnetic field gradients in MRI: numerical calculations and correlation analysis.

Authors:  Martin Bencsik; Richard Bowtell; Roger Bowley
Journal:  Phys Med Biol       Date:  2007-04-10       Impact factor: 3.609

View more
  21 in total

1.  Best current practice for obtaining high quality EEG data during simultaneous FMRI.

Authors:  Karen J Mullinger; Pierluigi Castellone; Richard Bowtell
Journal:  J Vis Exp       Date:  2013-06-03       Impact factor: 1.355

2.  Statistical feature extraction for artifact removal from concurrent fMRI-EEG recordings.

Authors:  Zhongming Liu; Jacco A de Zwart; Peter van Gelderen; Li-Wei Kuo; Jeff H Duyn
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

3.  Exploring the advantages of multiband fMRI with simultaneous EEG to investigate coupling between gamma frequency neural activity and the BOLD response in humans.

Authors:  Makoto Uji; Ross Wilson; Susan T Francis; Karen J Mullinger; Stephen D Mayhew
Journal:  Hum Brain Mapp       Date:  2018-01-13       Impact factor: 5.038

4.  An empirical investigation of motion effects in eMRI of interictal epileptiform spikes.

Authors:  Padmavathi Sundaram; Robert V Mulkern; William M Wells; Christina Triantafyllou; Tobias Loddenkemper; Ellen J Bubrick; Darren B Orbach
Journal:  Magn Reson Imaging       Date:  2011-05-08       Impact factor: 2.546

5.  Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject's axial position.

Authors:  Karen J Mullinger; Winston X Yan; Richard Bowtell
Journal:  Neuroimage       Date:  2010-10-13       Impact factor: 6.556

6.  Unified Retrospective EEG Motion Educated Artefact Suppression for EEG-fMRI to Suppress Magnetic Field Gradient Artefacts During Motion.

Authors:  Danilo Maziero; Victor A Stenger; David W Carmichael
Journal:  Brain Topogr       Date:  2021-09-23       Impact factor: 3.020

7.  Ballistocardiogram artifact removal with a reference layer and standard EEG cap.

Authors:  Qingfei Luo; Xiaoshan Huang; Gary H Glover
Journal:  J Neurosci Methods       Date:  2014-06-22       Impact factor: 2.390

8.  Presurgical brain mapping in epilepsy using simultaneous EEG and functional MRI at ultra-high field: feasibility and first results.

Authors:  Frédéric Grouiller; João Jorge; Francesca Pittau; Wietske van der Zwaag; Giannina Rita Iannotti; Christoph Martin Michel; Serge Vulliémoz; Maria Isabel Vargas; François Lazeyras
Journal:  MAGMA       Date:  2016-03-05       Impact factor: 2.310

9.  Motion-related artefacts in EEG predict neuronally plausible patterns of activation in fMRI data.

Authors:  Marije Jansen; Thomas P White; Karen J Mullinger; Elizabeth B Liddle; Penny A Gowland; Susan T Francis; Richard Bowtell; Peter F Liddle
Journal:  Neuroimage       Date:  2011-07-08       Impact factor: 6.556

10.  Identifying the sources of the pulse artefact in EEG recordings made inside an MR scanner.

Authors:  Karen J Mullinger; Jade Havenhand; Richard Bowtell
Journal:  Neuroimage       Date:  2013-01-08       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.