Literature DB >> 19822967

Electrochemical behavior and sensitive determination of L-tyrosine with a gold nanoparticles modified glassy carbon electrode.

Hao Cheng1, Changdong Chen, Shuai Zhang.   

Abstract

The electrocatalytic oxidation of L-tyrosine was investigated on a gold nanoparticles self-assembled glassy carbon electrode (gold nanoparticles/cysteamine/glassy carbon) using cyclic voltammetry and differential pulse voltammetry. Cyclic voltammetry was carried out to study the electrochemical oxidation mechanism of L-tyrosine, which showed an irreversible oxidation process at a potential of 0.681 V at a modified electrode and 0.807 V at a bare glassy carbon electrode. The anodic peak current linearly increased with the square root of the scan rate, suggesting that the oxidation of L-tyrosine at this kind of modified electrode is a diffusion-controlled process. A good linear relationship between the oxidation peak current and the L-tyrosine concentration in the range of 1.0 x 10(-7) to 3.0 x 10(-4) mol L(-1) was obtained in a phosphate buffer solution at pH 7.0. Good sensitivity, selectivity and stability of the modified electrode make it very suitable for L-tyrosine determination in a commercial amino acid oral solution.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19822967     DOI: 10.2116/analsci.25.1221

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  4 in total

Review 1.  Gold nanoparticles in chemical and biological sensing.

Authors:  Krishnendu Saha; Sarit S Agasti; Chaekyu Kim; Xiaoning Li; Vincent M Rotello
Journal:  Chem Rev       Date:  2012-02-02       Impact factor: 60.622

Review 2.  Advances in the design of nanomaterial-based electrochemical affinity and enzymatic biosensors for metabolic biomarkers: A review.

Authors:  Leila Farzin; Mojtaba Shamsipur; Leila Samandari; Shahab Sheibani
Journal:  Mikrochim Acta       Date:  2018-05-02       Impact factor: 5.833

3.  Electrochemical L-Tyrosine Sensor Based on a Glassy Carbon Electrode Modified with Exfoliated Graphene.

Authors:  Codruţa Varodi; Florina Pogăcean; Maria Coroş; Alexandra Ciorîță; Stela Pruneanu
Journal:  Sensors (Basel)       Date:  2022-05-10       Impact factor: 3.847

4.  A voltammetric sensor based on reduced graphene oxide-hemin-Ag nanocomposites for sensitive determination of tyrosine.

Authors:  Hui-Yu Zou; Xin-Yang Lu; Fen-Ying Kong; Zhong-Xia Wang; Heng-Ye Li; Hai-Lin Fang; Wei Wang
Journal:  RSC Adv       Date:  2020-07-28       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.