Literature DB >> 19822919

Use of ultrasonic pachymetry for measurement of changes in corneal thickness in mouse corneal transplant rejection.

T H Flynn1, M Ohbayashi, M Dawson, M Siddique, S J Ono, D F P Larkin.   

Abstract

BACKGROUND/AIMS: Diagnosis of rejection in the mouse model of corneal transplantation is based on subjective judgement of loss of graft transparency. The aims of this study were to (1) evaluate a pachymetry technique to measure changes in mouse corneal thickness and (2) correlate increases in transplant thickness with clinical and histological features of rejection.
METHODS: Orthotopic corneal allografts (C57BL/6 strain donor) and syngeneic grafts were performed in A/J mice. Graft transparency was graded and corneal thickness measured by pachymetry on alternate days. Transverse sections of donor cornea excised from eyes representative of clinical opacity grades 1-4 were prepared, photographed, graft section thickness measured and stromal graft-infiltrating cells counted. Intraobserver and interobserver variations in pachymetry were statistically tested.
RESULTS: Graft thickness, as measured by pachymetry, increased with each clinical opacity grade. Thickness for opacity grades 0, 1 and 2 was less than 300 microm in all recipients. Graft thickness for grades 3 and 4 was greater than 300 microm in all cases. For measurements up to 400 mum, there was a good correlation between thickness as measured by in vivo pachymetry and in histopathological sections. The mean interobserver bias was -11.35 microm, while the mean intraobserver bias was +3.96 microm. Stromal cellularity increased with increasing corneal thickness up to approximately 300 microm.
CONCLUSION: In vivo graft pachymetry provides a new and reliable way to objectively diagnose rejection in the mouse model of corneal transplantation.

Entities:  

Mesh:

Year:  2009        PMID: 19822919     DOI: 10.1136/bjo.2009.160671

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  5 in total

1.  Impact of repeated topical-loaded manganese-enhanced MRI on the mouse visual system.

Authors:  Shu-Wei Sun; Tiffany Thiel; Hsiao-Fang Liang
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-07-12       Impact factor: 4.799

2.  The Current State of Vaccine Development for Ocular HSV-1 Infection.

Authors:  D J Royer; A Cohen; Djj Carr
Journal:  Expert Rev Ophthalmol       Date:  2015-04-01

3.  Evaluation of corneal graft survival in mice model.

Authors:  Guo-Ling Chen; Jing-Jing Zhang; Jun Zhao; Da-Jiang Wang; Han Zhang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

4.  Optimizing rejection readouts in a corneal allograft transplantation model.

Authors:  Thabo Lapp; Antonia Hildebrand; Daniel Böhringer; Paola Kammrath Betancor; Günther Schlunck; Thomas Reinhard
Journal:  Mol Vis       Date:  2016-10-17       Impact factor: 2.367

5.  Near infra-red labelling and tracking of corneal endothelial cells in-vivo.

Authors:  Maninder Bhogal; Heng-Pei Ang; Shu-Jun Lin; Chan N Lwin; Khadijah Adnan; Gary Peh; Jodhbir S Mehta
Journal:  Sci Rep       Date:  2022-04-15       Impact factor: 4.379

  5 in total