Literature DB >> 19815436

Cross-calibration of iDXA and Prodigy on spine and femur scans in Korean adults.

Yong Jun Choi1, Byung Joo Lee, Hyun Chae Lim, Yoon-Sok Chung.   

Abstract

In this study, the authors compared bone mineral density (BMD) determined using GE Lunar iDXA and Prodigy and derived cross-calibration equations for the 2 devices in Korean adults. One hundred subjects (66 women and 34 men) participated in this study. Bone mineral density of spine and femur was measured by iDXA and Prodigy dual-energy X-ray absorptiometry (GE Lunar, Madison, WI). Subjects were divided into 3 groups. The first group (30 subjects) was scanned twice using Prodigy for precision testing and then once using iDXA. The second group (30 subjects) was scanned twice using iDXA and then once using Prodigy. Cross-calibration equations were derived using these results. The derived equations were tested in the third group (40 subjects). Predicted values from calculations based on Prodigy findings were compared with measured iDXA data. A significant difference was found between the BMD determined using the 2 devices (p < 0.001). However, linear regression analysis showed a high level of agreement between the two (r(2) from 0.984 to 0.994, p < 0.001). Bland-Altman analysis revealed no significant correlations between Prodigy and iDXA. Cross-calibration equations decreased systematic errors between Prodigy and iDXA by 0.4% at the spine, 0.8% at the femoral neck, and 0.1% at the total femur. A high level of agreement was found between Prodigy and iDXA in Korean adults. Cross-calibration equations proved reliable based on comparisons of measured and calculated BMD values.

Entities:  

Mesh:

Year:  2009        PMID: 19815436     DOI: 10.1016/j.jocd.2009.08.001

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.617


  4 in total

1.  BMD measurement and precision: a comparison of GE Lunar Prodigy and iDXA densitometers.

Authors:  Diane Krueger; Nellie Vallarta-Ast; Mary Checovich; Dessa Gemar; Neil Binkley
Journal:  J Clin Densitom       Date:  2011-11-09       Impact factor: 2.617

2.  Velaglucerase alfa (VPRIV) enzyme replacement therapy in patients with Gaucher disease: Long-term data from phase III clinical trials.

Authors:  Derralynn A Hughes; Derlis E Gonzalez; Elena A Lukina; Atul Mehta; Madhulika Kabra; Deborah Elstein; Isaac Kisinovsky; Pilar Giraldo; Ashish Bavdekar; Thomas N Hangartner; Nan Wang; Eric Crombez; Ari Zimran
Journal:  Am J Hematol       Date:  2015-07       Impact factor: 10.047

3.  Cross-Calibration of GE Healthcare Lunar Prodigy and iDXA Dual-Energy X-Ray Densitometers for Bone Mineral Measurements.

Authors:  J Saarelainen; M Hakulinen; T Rikkonen; H Kröger; M Tuppurainen; H Koivumaa-Honkanen; R Honkanen; M Hujo; J S Jurvelin
Journal:  J Osteoporos       Date:  2016-04-27

4.  Does Bone Mineral Density Differ between Fan-Beam and Pencil-Beam?: A Meta-Analysis and Systemic Review.

Authors:  Byung-Ho Yoon; Young Do Koh; Jun-Il Yoo; Sujin Kim; Guen Young Lee; Sung Bin Park; Yong-Chan Ha
Journal:  J Bone Metab       Date:  2021-02-28
  4 in total