Abstract

The objective of our study was to test alternative polymer-on-polymer articulations for cervical total disc arthroplasty with favourable biotribological properties and the benefit of radiolucency in comparison to the clinically well established metal-on-polyethylene coupling. In vitro wear simulation was performed according to ISO 18192-1:2008 (E) with the clinically introduced activ C cervical artificial disc (Aesculap AG Tuttlingen, Germany) made of UHMWPE/CoCr29Mo6 in a direct comparison to experimental disc articulations made of PEEK, CFR-PEEK and PEK. Each material combination was tested for 10 million cycles with a customised 6 station spinal wear simulator (EndoLab Thansau, Germany). Gravimetric and geometric wear assessment, optical surface characterisation and an estimation of particle size and morphology were performed. The gravimetric wear rate of the clinical reference polyethylene-on-cobalt-chromium was 1.0+/-0.1 mg/million cycles, compared to 1.4+/-0.4 mg/million cycles for PEEK, to 0.02+/-0.02 mg/million cycles for CFR-PEEK and 0.8+/-0.1 mg/million cycles for PEK. In conclusion, a number of different candidate materials for total cervical disc arthroplasty were compared using the same disc design. Whereas the polymer-on-polymer articulation of PEK showed no substantial benefit in comparison to polyethylene-on-cobalt-chromium and whereas natural PEEK tends towards pitting and delamination, the carbon fibre reinforced PEEK demonstrated an excellent wear behaviour with a reduction in order of a magnitude. Therefore, the CFR-PEEK based polymer-on-polymer articulations may be an alternative to polyethylene-on-metal and have a high potential for next generation disc replacements.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19815271     DOI: 10.1016/j.biomaterials.2009.09.064

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  15 in total

Review 1.  Cervical and lumbar spinal arthroplasty: clinical review.

Authors:  T D Uschold; D Fusco; R Germain; L M Tumialan; S W Chang
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

2.  The use of self-mating PEEK as an alternative bearing material for cervical disc arthroplasty: a comparison of different simulator inputs and tribological environments.

Authors:  Tim Brown; Qi-Bin Bao
Journal:  Eur Spine J       Date:  2012-03-14       Impact factor: 3.134

3.  A systematic review of cervical artificial disc replacement wear characteristics and durability.

Authors:  Ronald Lehman; Adam J Bevevino; Devon D Brewer; Andrea C Skelly; Paul A Anderson
Journal:  Evid Based Spine Care J       Date:  2012-02

4.  PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis.

Authors:  H Xin; Det Shepherd; Kd Dearn
Journal:  Open Biomed Eng J       Date:  2012-05-09

5.  Wear of the Charité® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator.

Authors:  Parshia Moghadas; Aziza Mahomed; Duncan E T Shepherd; David W L Hukins
Journal:  Proc Inst Mech Eng H       Date:  2015-03       Impact factor: 1.617

Review 6.  The Biologic Response to Polyetheretherketone (PEEK) Wear Particles in Total Joint Replacement: A Systematic Review.

Authors:  Ashley A Stratton-Powell; Kinga M Pasko; Claire L Brockett; Joanne L Tipper
Journal:  Clin Orthop Relat Res       Date:  2016-07-18       Impact factor: 4.176

7.  Analysis of Carbon Fiber Reinforced PEEK Hinge Mechanism Articulation Components in a Rotating Hinge Knee Design: A Comparison of In Vitro and Retrieval Findings.

Authors:  Ronja A Schierjott; Alexander Giurea; Hans-Joachim Neuhaus; Jens Schwiesau; Andreas M Pfaff; Sandra Utzschneider; Gianluca Tozzi; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2016-12-22       Impact factor: 3.411

8.  Delayed Hypersensitivity Reaction: An Increasingly Recognized Complication of Metal-on-Metal Total Disc Replacement.

Authors:  Mélodie-Anne Karnoub; Fahed Zairi; Rabih Aboukais; Richard Assaker
Journal:  Case Rep Orthop       Date:  2015-08-09

9.  Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.

Authors:  Ryan Siskey; Lauren Ciccarelli; Melissa K C Lui; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

10.  The innovative viscoelastic CP ESP cervical disk prosthesis with six degrees of freedom: biomechanical concepts, development program and preliminary clinical experience.

Authors:  Jean-Yves Lazennec; Alain Aaron; Olivier Ricart; Jean Patrick Rakover
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-09-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.