Literature DB >> 19813421

CaPO4 blasted implants inserted into iliac crest homologue frozen grafts.

Maurizio Franco1, Leone Rigo, Alessandro Viscione, Bruno De Santis, Emanuela Tropina, Giorgio Brunelli, Riccardo Guidi, Anna Avantaggiato, Francesco Carinci.   

Abstract

In the last decade, some investigations have reported that the resorbable blast media surface (also named CaPO4 blasted implants [CaPO4-Bls]) has achieved excellent results. However, no report regarding CaPO4-Bls inserted into fresh frozen bone (FFB) is available. Thus, we planned a retrospective study on a series of CaPO4-Bls inserted into FFB to evaluate their clinical outcome. In the period between December 2003 and December 2006, 16 patients (10 females and 6 males, median age of 55 years) were operated on, and 76 CaPO4-Bls were inserted. The mean implant follow-up was 23 months. Implant diameter and length ranged from 3.25 to 4.5 mm and from 11.5 to 15 mm, respectively. Implants were inserted to replace 7 incisors, 11 cuspids, 31 premolars, and 27 molars. Only 1 out of 76 implants was lost (i.e., survival rate [SVR] = 98.7%), and no differences were detected among the studied variables. When peri-implant crestal bone resorption was used as an indicator of clinical success (i.e., success rate), it was possible to identify some variables that correlated with a better clinical outcome. Specifically, Cox regression showed that removable prosthetic restoration and longer implant length correlated with a statistically significant lower delta implant abutment junction (IAJ; i.e., reduced crestal bone loss) and thus a better clinical outcome. In this study, CaPO4-Bls had high survival and success rates, similar to those reported in previous reports of 2-stage procedures in nongrafted bone. CaPO4-Bls inserted into FFB are reliable devices, although greater marginal bone loss occurs when fixed prosthetic restorations and short implants are used.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19813421     DOI: 10.1563/1548-1336-35.4.176

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  17 in total

1.  Genetic susceptibility and periodontal disease: a retrospective study on a large italian sample.

Authors:  L Tettamanti; R M Gaudio; A Iapichino; D Mucchi; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-04-10

2.  Polymerization shrinkage and spherical glass mega fillers: effects on cuspal deflection.

Authors:  M Andreasi Bassi; S Serra; C Andrisani; S Lico; L Baggi; D Lauritano
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

3.  Efficacy of a new coating of implant-abutment connections in reducing bacterial loading: an in vitro study.

Authors:  D Lauritano; C A Bignozzi; D Pazzi; F Cura; F Carinci
Journal:  Oral Implantol (Rome)       Date:  2017-04-10

4.  Prevalence of periodontal pathogens among italian patients with chronic periodontitis: a retrospective study on 2992 patients.

Authors:  L Tettamanti; R M Gaudio; F Cura; D Mucchi; N Illuzzi; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-04-10

5.  Light diffusion through composite restorations added with spherical glass mega fillers.

Authors:  M Andreasi Bassi; S Andreasi Bassi; C Andrisani; S Lico; L Baggi; D Lauritano
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

6.  Ultrasound and analysis of the deformation patterns of the masseter muscle: comparing surgical anatomy, ultrasound and functional anatomy.

Authors:  A Busato; G Balconi; V Vismara; L Bertelè; G Garo; D DE Gregorio
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

7.  Surgiplanner: a new method for one step oral rehabilitation of severe atrophic maxilla.

Authors:  A Busato; V Vismara; F Grecchi; E Grecchi; D Lauritano
Journal:  Oral Implantol (Rome)       Date:  2017-11-30

8.  Management and control of isotonic contraction generated stress: evaluation of masseter muscle deformation pattern by means of ecography.

Authors:  A Busato; G Balconi; V Vismara; L Bertelè; G Garo; D DE Gregorio
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

9.  Analysis of masseter deformation patterns during a maximum exertion clenching in patients with unilateral chewing.

Authors:  A Busato; G Balconi; V Vismara; L Bertelè; G Garo; D DE Gregorio
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

10.  A new surgical and technical approach in zygomatic implantology.

Authors:  F Grecchi; A E Bianchi; S Siervo; E Grecchi; D Lauritano; F Carinci
Journal:  Oral Implantol (Rome)       Date:  2017-09-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.