Three-dimensional ultrasound for image-guided mapping and intervention: methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system.

Yasuo Okumura1, Benhur D Henz, Susan B Johnson, T Jared Bunch, Christine J O'Brien, David O Hodge, Andres Altman, Assaf Govari, Douglas L Packer.   

Abstract

BACKGROUND: Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. METHODS AND
RESULTS: Twelve dogs underwent evaluation using a newly developed Carto-based 3D ultrasound system. After fiducial clip markers were percutaneously implanted at critical locations in each cardiac chamber, 3D ultrasound geometries, derived from a family of 2D intracardiac echocardiographic images, were constructed. Point-source error of 3D ultrasound-derived geometries, assessed by actual real-time 2D intracardiac echocardiographic clip sites, was 2.1+/-1.1 mm for atrial and 2.4+/-1.2 mm for ventricular sites. These errors were significantly less than the variance on CartoMerge computed tomographic images (atria: 3.3+/-1.6 mm; ventricles: 4.8+/-2.0 mm; P<0.001 for both). Target ablation at each clip, guided only by 3D ultrasound-derived geometry, resulted in lesions within 1.1+/-1.1 mm of the actual clips. Pulmonary vein ablation guided by 3D ultrasound-derived geometry resulted in circumferential ablative lesions. Mapping in 15 patients produced modestly smaller 3D ultrasound versus electroanatomic map left atrial volumes (98+/-24 cm(3) versus 109+/-25 cm(3), P<0.05). Three-dimensional ultrasound-guided pulmonary vein isolation and linear ablation in these patients were successfully performed with confirmation of pulmonary vein entrance/exit block.
CONCLUSIONS: These data demonstrate that 3D ultrasound images seamlessly yield anatomically accurate chamber geometries. Image volumes from the ultrasound system are more accurate than possible with CartoMerge computed tomographic imaging. This clinical study also demonstrates the initial feasibility of this guidance system for ablation in patients with atrial fibrillation.

Entities:  

Mesh:

Year:  2008        PMID: 19808401     DOI: 10.1161/CIRCEP.108.769935

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  17 in total

Review 1.  Fusion of imaging technologies: how, when, and for whom?

Authors:  Ashul Govil; Hugh Calkins; David D Spragg
Journal:  J Interv Card Electrophysiol       Date:  2011-10-01       Impact factor: 1.900

Review 2.  Use of imaging techniques to guide catheter ablation procedures.

Authors:  Melissa R Robinson; Mathew D Hutchinson
Journal:  Curr Cardiol Rep       Date:  2010-09       Impact factor: 2.931

3.  A probabilistic framework for freehand 3D ultrasound reconstruction applied to catheter ablation guidance in the left atrium.

Authors:  Aditya B Koolwal; Federico Barbagli; Christopher R Carlson; David H Liang
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-06-04       Impact factor: 2.924

4.  DTI template-based estimation of cardiac fiber orientations from 3D ultrasound.

Authors:  Xulei Qin; Baowei Fei
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

5.  Phantom with multiple active points for ultrasound calibration.

Authors:  Haichong K Zhang; Alexis Cheng; Younsu Kim; Qianli Ma; Gregory S Chirikjian; Emad M Boctor
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-27

Review 6.  [Three-dimensional mapping systems].

Authors:  Philipp Halbfass; Oliver Turschner; Christian Mahnkopf; Johannes Brachmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-11-28

Review 7.  Intracardiac echocardiography in complex cardiac catheter ablation procedures.

Authors:  Javier E Banchs; Parag Patel; Gerald V Naccarelli; Mario D Gonzalez
Journal:  J Interv Card Electrophysiol       Date:  2010-05-18       Impact factor: 1.900

Review 8.  The Evolving Utility Of Intracardiac Echocardiography In Cardiac Procedures.

Authors:  Christopher F Liu
Journal:  J Atr Fibrillation       Date:  2014-04-30

Review 9.  Intracardiac echocardiography during interventional and electrophysiological cardiac catheterization.

Authors:  Ziyad M Hijazi; Kalyanam Shivkumar; David J Sahn
Journal:  Circulation       Date:  2009-02-03       Impact factor: 29.690

10.  Recent trends in imaging for atrial fibrillation ablation.

Authors:  Rajesh Kabra; Jagmeet Singh
Journal:  Indian Pacing Electrophysiol J       Date:  2010-05-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.