Literature DB >> 19805751

Ductus venosus pulsatility index as an antenatal screening marker for Down's syndrome: use with the Combined and Integrated tests.

A Borrell1, V Borobio, J P Bestwick, N J Wald.   

Abstract

OBJECTIVES: To assess the value of ductus venosus blood flow (expressed as pulsatility index, DVPI) in antenatal Down's syndrome screening when used with the Combined and Integrated tests.
METHODS: DVPI measurements between 10 and 13 weeks' gestation in 66 Down's syndrome and 7184 unaffected pregnancies were collected from women attending the Hospital Clinic, Barcelona, for antenatal care from 1999 to 2007 and combined with the Serum Urine and Ultrasound Screening Study (SURUSS) data to model screening performance, safety and cost-effectiveness of the screening tests with and without DVPI.
RESULTS: The median DVPI multiple of the normal median in Down's syndrome pregnancies was 1.55 (95% CI 1.36-1.73). As a single screening marker without using maternal age, DVPI has a 62% detection rate for a 5% false-positive rate. At a 90% detection rate (first trimester measurements at 11 weeks' gestation) the addition of DVPI reduced the false-positive rate of the Combined test from 8.5% to 4.6% and the Integrated test from 2.0% to 1.1%, with a corresponding reduction in fetal losses from diagnostic procedures. There was no material loss of cost-effectiveness.
CONCLUSION: Addition of DVPI measurements to the Combined and Integrated tests substantially improves the efficacy and safety of antenatal Down's syndrome screening.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19805751     DOI: 10.1258/jms.2009.009043

Source DB:  PubMed          Journal:  J Med Screen        ISSN: 0969-1413            Impact factor:   2.136


  5 in total

1.  Community Corner: Opening the Pandora's box of prenatal genetic testing.

Authors:  Caroline Wright; Stephen R Quake; Diana Bianchi; Nicholas J Wald
Journal:  Nat Med       Date:  2011-03       Impact factor: 53.440

Review 2.  First trimester ultrasound tests alone or in combination with first trimester serum tests for Down's syndrome screening.

Authors:  S Kate Alldred; Yemisi Takwoingi; Boliang Guo; Mary Pennant; Jonathan J Deeks; James P Neilson; Zarko Alfirevic
Journal:  Cochrane Database Syst Rev       Date:  2017-03-15

Review 3.  First and second trimester serum tests with and without first trimester ultrasound tests for Down's syndrome screening.

Authors:  S Kate Alldred; Yemisi Takwoingi; Boliang Guo; Mary Pennant; Jonathan J Deeks; James P Neilson; Zarko Alfirevic
Journal:  Cochrane Database Syst Rev       Date:  2017-03-15

4.  Doppler assessment of the ductus venosus and the tricuspid valve at 11-13+6 weeks: Reference ranges and development of sonographic quality assurance standards.

Authors:  Vanessa Pincham; Jon Hyett; Karen Pollard; Philip Schluter; Andrew McLennan
Journal:  Australas J Ultrasound Med       Date:  2016-02-21

5.  Improvements in antenatal screening for Down's syndrome.

Authors:  N J Wald; J P Bestwick; W J Huttly
Journal:  J Med Screen       Date:  2013-05-13       Impact factor: 2.136

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.