Manual B-mode versus automated radio-frequency carotid intima-media thickness measurements.

Soner Dogan1, Yvonne Plantinga, Joke M Dijk, Yolanda van der Graaf, Diederick E Grobbee, Michiel L Bots.   

Abstract

BACKGROUND: Carotid intima-media thickness (CIMT) serves as an indicator of atherosclerosis and cardiovascular risk. Manual measurements of B-mode ultrasound images are the most applied method. Automated measurements with radiofrequency (RF) ultrasound have been suggested as an alternative. The aim of this study was to compare these methods in terms of risk-factor relations and associations with future events.
METHODS: Data from participants of the Second Manifestations of Arterial Disease (SMART) study were used. Far wall common CIMT was measured online with manual B-mode and automated RF ultrasound. Measurements were performed by a group of 6 sonographers. Risk-factor information was obtained. All participants were followed for the occurrence of vascular events (mean follow-up, 2.1 years). CIMT was related to risk factors with linear regression models and to future events with Cox proportional-hazards models.
RESULTS: Data were available for 2,146 participants. Agreement between the methods was modest (intraclass correlation coefficient = 0.34). Risk-factor relations with age and systolic blood pressure were stronger for B-mode than for RF ultrasound. Association with future events was better for B-mode than for RF ultrasound (vascular death, 1.27 vs 1.00; ischemic stroke, 1.45 vs 1.03). In participants with CIMT < 0.9 mm (without plaque), the intraclass correlation between the measures was 0.50. In addition, in that subgroup, RF ultrasound showed a stronger association with future events than B-mode ultrasound (all events, 1.59 vs 1.09; vascular death, 1.72 vs 0.93; coronary ischemic events, 1.65 vs 1.05).
CONCLUSIONS: The preference for either B-mode or RF measurements may be driven by the type of study population, the expected presence of local atherosclerotic abnormalities, and the main aim of the study (assessing risk factors or events). However, in this study, as in many others, the B-mode approach was shown to be robust in risk-factor relations and the prediction of events.

Entities:  

Mesh:

Year:  2009        PMID: 19801303     DOI: 10.1016/j.echo.2009.07.008

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

1.  Can ultrasonographic measurement of carotid intima-media thickness predict hypotension after induction of general anesthesia?

Authors:  Ayhan Kaydu; Dilek Duman Güven; Erhan Gökcek
Journal:  J Clin Monit Comput       Date:  2018-11-21       Impact factor: 2.502

2.  Association of multiple biomarkers and classical risk factors with early carotid atherosclerosis: results from the Gutenberg Health Study.

Authors:  Christoph Sinning; Arne Kieback; Philipp S Wild; Renate B Schnabel; Francisco Ojeda; Sebastian Appelbaum; Tanja Zeller; Edith Lubos; Edzard Schwedhelm; Karl J Lackner; Eike S Debus; Thomas Munzel; Stefan Blankenberg; Christine Espinola-Klein
Journal:  Clin Res Cardiol       Date:  2014-02-02       Impact factor: 5.460

3.  Mannheim carotid intima-media thickness and plaque consensus (2004-2006-2011). An update on behalf of the advisory board of the 3rd, 4th and 5th watching the risk symposia, at the 13th, 15th and 20th European Stroke Conferences, Mannheim, Germany, 2004, Brussels, Belgium, 2006, and Hamburg, Germany, 2011.

Authors:  P-J Touboul; M G Hennerici; S Meairs; H Adams; P Amarenco; N Bornstein; L Csiba; M Desvarieux; S Ebrahim; R Hernandez Hernandez; M Jaff; S Kownator; T Naqvi; P Prati; T Rundek; M Sitzer; U Schminke; J-C Tardif; A Taylor; E Vicaut; K S Woo
Journal:  Cerebrovasc Dis       Date:  2012-11-01       Impact factor: 2.762

4.  Surface roughness detection of arteries via texture analysis of ultrasound images for early diagnosis of atherosclerosis.

Authors:  Lili Niu; Ming Qian; Wei Yang; Long Meng; Yang Xiao; Kelvin K L Wong; Derek Abbott; Xin Liu; Hairong Zheng
Journal:  PLoS One       Date:  2013-10-17       Impact factor: 3.240

Review 5.  Carotid Intima-media Thickness Measurements: Relations with Atherosclerosis, Risk of Cardiovascular Disease and Application in Randomized Controlled Trials.

Authors:  Michiel L Bots; Gregory W Evans; Charles H Tegeler; Rudy Meijer
Journal:  Chin Med J (Engl)       Date:  2016-01-20       Impact factor: 2.628

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.