[Placement repeatability of individual oral stent used in radiotherapy of nasopharyngeal carcinoma].

Xiao-Qing Liu1, Wei Luo, Shi-Rong Lin, Meng-Zhong Liu.   

Abstract

BACKGROUND AND
OBJECTIVE: Individual oral stent used in nasopharyngeal carcinoma (NPC) patients during radiotherapy can spare the oral mucosa and tongue. This study was to analyze the placement repeatability and feasibility of individual oral stent used in radiotherapy of NPC.
METHODS: Individual oral stents were made for 17 naive NPC patients, and three lead markers of 2.0 mm diameter were embedded in each oral stent. The patients wearing individual oral stent were immobilized by thermoplast mask and underwent CT scan. Before and every week during radiotherapy, orthogonal (antero-posterior and lateral) X-ray films were taken in conventional simulator, respectively. Displacements of leader markers in medio-lateral (M-L),antero-posterior (A-P) and cranio-caudal (C-C) directions were respectively calculated and compared on each patient's X-ray films. At the dose of 40 Gy, a repeated CT scan was done with the same thermoplast mask and positioning markers. The displacements of co-ordinating gravity center of three lead markers and three selected bony structures between two sets of CT images for each patient were calculated and compared by ANOVA.
RESULTS: A total of 240 X-ray films were taken. The displacements of lead markers were (0.69+/-0.54) mm in M-L direction, (0.49+/-0.62) mm in A-P direction, and (0.56+/-0.57) mm in C-C direction, and the overall vector displacement was (1.2+/-0.77) mm (range, 0-4.98 mm). In three-dimensional method, the displacements of co-ordinating gravity center of three lead markers were (0.75+/-0.68) mm in M-L direction, (1.25+/-1.12) mm in A-P direction, and (1.06+/-0.77) mm in C-C direction, and the overall vector displacement was (2.15+/-0.90) mm (range, 1-4.24 mm). The displacements between gravity center of three lead markers and three bony structures had no significant difference in M-L, A-P, and C-C directions (P>0.05). The overall vector displacements also had no significant difference (P=0.083).
CONCLUSION: The placement repeatability of individual oral dental stent in the mouth is very good during radiotherapy of NPC, and dental stent has a fixed position relationship with bony structures.

Entities:  

Mesh:

Year:  2009        PMID: 19799822     DOI: 10.5732/cjc.009.10010

Source DB:  PubMed          Journal:  Ai Zheng


  3 in total

1.  A simplified technique to fabricate tissue bolus device to manage dose distribution in maxillectomy patient with orbital exenteration.

Authors:  Balendra Pratap Singh; Nungtso Vero; Punit Kumar Singh; Teerath Raj Verma
Journal:  J Oral Biol Craniofac Res       Date:  2013-04-09

2.  Are intraoral customized stents still necessary in the era of Highly Conformal Radiotherapy for Head & Neck cancer? Case series and literature review.

Authors:  P Appendino; F Della Ferrera; D Nassisi; G Blandino; E Gino; S D Solla; M G Ruo Redda
Journal:  Rep Pract Oncol Radiother       Date:  2019-08-20

3.  Effect of Body Size Change on Off-Center Cervical Point and Face Doses in Patients Undergoing Nasopharyngeal Carcinoma Radiotherapy.

Authors:  Meifang Fang; Lu Xu; Xianxiang Wu; Zhen Cui; Zelai He; Haoxuan Zhang; Hao Jin
Journal:  Dis Markers       Date:  2022-04-25       Impact factor: 3.434

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.