| Literature DB >> 19798356 |
Abstract
A white-light interferometric extrinsic Fabry-Perot strain sensor that uses a multimode fiber is demonstrated. The Fabry-Perot cavity length is measured with the help of a Fizeau interferometer. The sensor is described, and some results obtained at this time are given. The strain measurements are absolute and perfectly linear, with a sensitivity of 0.25 micrometers per meter (micro). the design of a thermally autocompensated strain sensor is also presented.Year: 1993 PMID: 19798356 DOI: 10.1364/ol.18.000078