Literature DB >> 19796507

Determination of digoxin and digitoxin in whole blood.

Elisabeth Leere Oiestad1, Unni Johansen, Mimi Stokke Opdal, Stein Bergan, Asbjørg Solberg Christophersen.   

Abstract

A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for the determination of digoxin and digitoxin in whole blood samples in autopsy cases. Samples were prepared by liquid-liquid extraction (LLE) with ethyl acetate/heptane/dichloromethane (3:1:1). LC separation was achieved using an Atlantis dC(18)-column (2.1 x 50 mm, 3 microm). The time between injections was 11 min. Mass detection was performed by positive ion mode electrospray LC-MS-MS on the ammonium adducts with two transitions for each analyte and one for the internal standard (digoxin-d(3)). Within-day precision was between 8.3 and 10.8%, between-day precision was between 8.7 and 14.2% and accuracy (bias) was between -17.3 and 11.5%. LOQ was 0.1 nmol/L (0.08 ng/mL), with an accuracy and precision of 19% and -17% (digoxin) and 18% and 3% (digitoxin). Matrix effects ranged from 104 to 117%. Good qualitative correlation with previous findings was achieved for 38 autopsy cases. The median (range, number of cases) B-digitoxin and B-digoxin found with the LC-MS-MS method in this very limited material were 9.3 (3.4-23.8, n = 24) and 5.6 (3.4-26.5, n = 4) nmol/L, respectively.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19796507     DOI: 10.1093/jat/33.7.372

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  4 in total

1.  Analysis of digoxin and metildigoxin in whole blood using solid-phase extraction and liquid chromatography tandem mass spectrometry.

Authors:  Paula Melo; Rita Machado; Helena M Teixeira
Journal:  Int J Anal Chem       Date:  2011-06-22       Impact factor: 1.885

2.  Molecular transport through primary human small intestinal monolayers by culture on a collagen scaffold with a gradient of chemical cross-linking.

Authors:  Jennifer E Speer; Dulan B Gunasekara; Yuli Wang; John K Fallon; Peter J Attayek; Philip C Smith; Christopher E Sims; Nancy L Allbritton
Journal:  J Biol Eng       Date:  2019-04-27       Impact factor: 4.355

3.  Electrochemically driven optical and SERS immunosensor for the detection of a therapeutic cardiac drug.

Authors:  Madeeha Chaudhry; Dong-Kwon Lim; Jeon Woong Kang; Zahid Yaqoob; Peter So; Muhammad Fahad Bhopal; Minqiang Wang; Raheel Qamar; Arshad Saleem Bhatti
Journal:  RSC Adv       Date:  2022-01-20       Impact factor: 3.361

4.  Development of a new ultra-high-performance liquid chromatography-tandem mass spectrometry method for the determination of digoxin and digitoxin in plasma: Comparison with a clinical immunoassay.

Authors:  Marco Ballotari; Francesco Taus; Giulia Tolle; Elisa Danese; Romolo M Dorizzi; Franco Tagliaro; Rossella Gottardo
Journal:  Electrophoresis       Date:  2022-02-17       Impact factor: 3.595

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.