Plasma disappearance rate of indocyanine green: a tool to evaluate early graft outcome after liver transplantation.

Eric Levesque1, Faouzi Saliba, Sonia Benhamida, Philippe Ichaï, Daniel Azoulay, René Adam, Denis Castaing, Didier Samuel.   

Abstract

Indocyanine green clearance (Cl-ICG) has been used to assess liver function and hepatic blood flow mainly before and after hepatic surgery. Cl-ICG (invasive method) has been reported to be a good marker of early graft function after liver transplantation (LT). The goal of this study was to determine if the indocyanine green plasma disappearance rate (PDR-ICG), measured by a noninvasive technique (LiMON, Impulse Medical System, Munich, Germany), is predictive of complications and graft outcome after LT. From September 2005 to June 2006, 72 LT recipients were included in the study. PDR-ICG was measured daily (from day 0 to day 5 after LT) with a digital sensor after patients were injected with 0.25 mg/kg indocyanine green. A PDR-ICG cutoff level of 12.85%/minute was predictive of the development of a serious postoperative complication. The sequential changes of PDR-ICG enabled us to differentiate 2 groups: (1) patients with early severe complications (hepatic artery thrombosis, primary graft nonfunction, or sepsis) who had a low value of PDR-ICG during the first 5 posttransplantation days (average, 8.8 +/- 4.5%/minute) and (2) patients who developed acute rejection and who had a progressive reduction of PDR-ICG between days 0 and 5 (from 25.5 +/- 4.8 to 10.3 +/- 2.5%/minute; P < 0.002). In conclusion, after LT, PDR-ICG (a noninvasive technique), measured regularly during the first 5 postoperative days, is a safe technique that can predict early postoperative complications. Copyright 2009 AASLD

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19790157     DOI: 10.1002/lt.21805

Source DB:  PubMed          Journal:  Liver Transpl        ISSN: 1527-6465            Impact factor:   5.799


  25 in total

1.  Indocyanine green dye clearance test: early graft (dys)-function and long-term mortality after liver transplant. Should we continue to use it? An observational study.

Authors:  Vittorio Cherchi; Luigi Vetrugno; Victor Zanini; Thomas Isler; Riccardo Pravisani; Alice Borghi; Umberto Baccarani; Giovanni Terrosu; Andrea Risaliti; Tiziana Bove
Journal:  J Clin Monit Comput       Date:  2020-03-12       Impact factor: 2.502

Review 2.  Post-hepatectomy liver failure in patients with colorectal liver metastases.

Authors:  Masato Narita; Elie Oussoultzoglou; Philippe Bachellier; Daniel Jaeck; Shinji Uemoto
Journal:  Surg Today       Date:  2015-01-29       Impact factor: 2.549

3.  Minimally invasive method for the point-of-care quantification of lymphatic vessel function.

Authors:  Anna K Polomska; Steven T Proulx; Davide Brambilla; Daniel Fehr; Mathias Bonmarin; Simon Brändli; Mirko Meboldt; Christian Steuer; Tsvetina Vasileva; Nils Reinke; Jean-Christophe Leroux; Michael Detmar
Journal:  JCI Insight       Date:  2019-02-21

4.  Intraoperative ICG plasma disappearance rate helps to predict absence of early postoperative complications after orthotopic liver transplantation.

Authors:  J J Vos; T W L Scheeren; D J Lukes; M T de Boer; H G D Hendriks; J K G Wietasch
Journal:  J Clin Monit Comput       Date:  2013-05-16       Impact factor: 2.502

5.  Intraoperative simulation of remnant liver function during anatomic liver resection with indocyanine green clearance (LiMON) measurements.

Authors:  Michael N Thomas; Ernst Weninger; Martin Angele; Florian Bösch; Sebastian Pratschke; Joachim Andrassy; Markus Rentsch; Manfred Stangl; Werner Hartwig; Jens Werner; Markus Guba
Journal:  HPB (Oxford)       Date:  2015-01-08       Impact factor: 3.647

6.  The combination of indocyanine green clearance test and model for end-stage liver disease score predicts early graft outcome after liver transplantation.

Authors:  Tang Yunhua; Ju Weiqiang; Chen Maogen; Yang Sai; Zhang Zhiheng; Wang Dongping; Guo Zhiyong; He Xiaoshun
Journal:  J Clin Monit Comput       Date:  2017-08-22       Impact factor: 2.502

Review 7.  Indocyanine green kinetics to assess liver function: Ready for a clinical dynamic assessment in major liver surgery?

Authors:  Andrea De Gasperi; Ernestina Mazza; Manlio Prosperi
Journal:  World J Hepatol       Date:  2016-03-08

Review 8.  Assessment of liver perfusion and function by indocyanine green in the perioperative setting and in critically ill patients.

Authors:  Samir G Sakka
Journal:  J Clin Monit Comput       Date:  2017-10-16       Impact factor: 2.502

Review 9.  [Monitoring of liver function in the critically ill].

Authors:  C Sponholz; F A Gonnert; A Kortgen; M Bauer
Journal:  Anaesthesist       Date:  2014-07       Impact factor: 1.041

Review 10.  Predictive factors of short term outcome after liver transplantation: A review.

Authors:  Giuliano Bolondi; Federico Mocchegiani; Roberto Montalti; Daniele Nicolini; Marco Vivarelli; Lesley De Pietri
Journal:  World J Gastroenterol       Date:  2016-07-14       Impact factor: 5.742