PURPOSE: ALI and ARDS are associated with lung volume derecruitment, usually counteracted by PEEP and recruitment maneuvers (RM), which should be accurately tailored to the patient's needs. The aim of this study was to investigate the possibility of monitoring the amount of derecruited lung by the forced oscillation technique (FOT). METHODS: We studied six piglets (26 +/- 2.5 kg) ventilated by a mechanical ventilator connected to a FOT device that produced sinusoidal pressure forcing at 5 Hz. The percentage of non-aerated lung tissue (V (tiss)NA%) was measured by whole-body CT scans at end-expiration with zero end-expiratory pressure. Respiratory system oscillatory input reactance (X (rs)) was measured simultaneously to CT and used to derive oscillatory compliance (C (X5)), which we used as an index of recruited lung. Measurements were performed at baseline and after several interventions in the following sequence: mono-lateral reabsorption atelectasis, RM, bi-lateral derecruitment induced by broncho-alveolar lavage and a second RM. RESULTS: By pooling data from all experimental conditions and all pigs, C (X5) was linearly correlated to V (tiss)NA% (r (2) = 0.89) regardless of the procedure used to de-recruit the lung (reabsorption atelectasis or pulmonary lavage). Separate correlation analysis on single pigs showed similar regression equations, with an even higher coefficient of determination (r (2) = 0.91 +/- 0.07). CONCLUSION: These results suggest that FOT and the measurement of C (X5) could be a useful tool for the non-invasive measurement of lung volume recruitment/derecruitment.
PURPOSE: ALI and ARDS are associated with lung volume derecruitment, usually counteracted by PEEP and recruitment maneuvers (RM), which should be accurately tailored to the patient's needs. The aim of this study was to investigate the possibility of monitoring the amount of derecruited lung by the forced oscillation technique (FOT). METHODS: We studied six piglets (26 +/- 2.5 kg) ventilated by a mechanical ventilator connected to a FOT device that produced sinusoidal pressure forcing at 5 Hz. The percentage of non-aerated lung tissue (V (tiss)NA%) was measured by whole-body CT scans at end-expiration with zero end-expiratory pressure. Respiratory system oscillatory input reactance (X (rs)) was measured simultaneously to CT and used to derive oscillatory compliance (C (X5)), which we used as an index of recruited lung. Measurements were performed at baseline and after several interventions in the following sequence: mono-lateral reabsorption atelectasis, RM, bi-lateral derecruitment induced by broncho-alveolar lavage and a second RM. RESULTS: By pooling data from all experimental conditions and all pigs, C (X5) was linearly correlated to V (tiss)NA% (r (2) = 0.89) regardless of the procedure used to de-recruit the lung (reabsorption atelectasis or pulmonary lavage). Separate correlation analysis on single pigs showed similar regression equations, with an even higher coefficient of determination (r (2) = 0.91 +/- 0.07). CONCLUSION: These results suggest that FOT and the measurement of C (X5) could be a useful tool for the non-invasive measurement of lung volume recruitment/derecruitment.
Authors: Pier Paolo Terragni; Giulio Rosboch; Andrea Tealdi; Eleonora Corno; Eleonora Menaldo; Ottavio Davini; Giovanni Gandini; Peter Herrmann; Luciana Mascia; Michel Quintel; Arthur S Slutsky; Luciano Gattinoni; V Marco Ranieri Journal: Am J Respir Crit Care Med Date: 2006-10-12 Impact factor: 21.405
Authors: Alysson R S Carvalho; Frederico C Jandre; Alexandre V Pino; Fernando A Bozza; Jorge I Salluh; Rosana Rodrigues; Joao H N Soares; Antonio Giannella-Neto Journal: Crit Care Date: 2006 Impact factor: 9.097
Authors: Raffaele L Dellacà; Emanuela Zannin; Peter Kostic; Marie Andersson Olerud; Pasquale P Pompilio; Goran Hedenstierna; Antonio Pedotti; Peter Frykholm Journal: Intensive Care Med Date: 2011-04-01 Impact factor: 17.440
Authors: Raffaele L Dellacà; C Veneroni; V Vendettuoli; E Zannin; P G Matassa; A Pedotti; M Colnaghi; F Mosca Journal: Intensive Care Med Date: 2013-01-11 Impact factor: 17.440
Authors: S A Bhatawadekar; D Leary; V de Lange; U Peters; S Fulton; P Hernandez; C McParland; G N Maksym Journal: J Appl Physiol (1985) Date: 2019-10-24
Authors: Massimo Antonelli; Elie Azoulay; Marc Bonten; Jean Chastre; Giuseppe Citerio; Giorgio Conti; Daniel De Backer; François Lemaire; Herwig Gerlach; Goran Hedenstierna; Michael Joannidis; Duncan Macrae; Jordi Mancebo; Salvatore M Maggiore; Alexandre Mebazaa; Jean-Charles Preiser; Jerôme Pugin; Jan Wernerman; Haibo Zhang Journal: Intensive Care Med Date: 2010-01-28 Impact factor: 17.440
Authors: Emanuela Zannin; Raffaele L Dellaca; Peter Kostic; Pasquale P Pompilio; Anders Larsson; Antonio Pedotti; Goran Hedenstierna; Peter Frykholm Journal: Crit Care Date: 2012-11-07 Impact factor: 9.097