Literature DB >> 19786781

Three- and four-dimensional fetal echocardiography.

Sifa Turan1, Ozhan Turan, Ahmet A Baschat.   

Abstract

The rapid continuing development of 3-dimensional ultrasound imaging technologies has extended capabilities of fetal cardiac scanning beyond 2-dimensional imaging technologies and now provides a wide array of analytic possibilities. The acquisition of the 3D volume information is based on initial application of 2-dimensional imaging techniques including grey scale, Doppler, Power Doppler and B-flow modalities. Once the cardiac volume is obtained a combination of postprocessing tools such as surface mode, minimal mode, transverse rendering, inversion and glass body modes allow preferential display of various features of the fetal heart. Motion display modes including cine-loop and spatiotemporal image correlation in combination with automated and semiautomated display of examination planes opens a whole new array of diagnostic possibilities in clinical practice.

Mesh:

Year:  2009        PMID: 19786781     DOI: 10.1159/000236148

Source DB:  PubMed          Journal:  Fetal Diagn Ther        ISSN: 1015-3837            Impact factor:   2.587


  5 in total

1.  Multi-modality Echocardiography for Cardiac Assessment in Fetuses of Pregnant Women With Diabetes Mellitus.

Authors:  Hee Joung Choi
Journal:  J Cardiovasc Imaging       Date:  2022-04

2.  Application of spatio-temporal image correlation technology in the diagnosis of fetal cardiac abnormalities.

Authors:  Yihua He; Junlan Wang; Xiaoyan Gu; Ye Zhang; Jiancheng Han; Xiaowei Liu; Zhian Li
Journal:  Exp Ther Med       Date:  2013-04-09       Impact factor: 2.447

3.  Color and power Doppler combined with Fetal Intelligent Navigation Echocardiography (FINE) to evaluate the fetal heart.

Authors:  L Yeo; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2017-08-14       Impact factor: 7.299

4.  The Ultrasonic Microsurgical Anatomical Comparative Study of the CHD Fetuses and Their Clinical Significance.

Authors:  Xiaosong Li; Hongmei Xia; Dan Wang; Junke Zhu; Jianhua Ran
Journal:  Biomed Res Int       Date:  2015-11-10       Impact factor: 3.411

5.  B-flow/spatiotemporal image correlation M-mode: novel ultrasound method that detects decrease in spiral artery luminal diameter in first trimester in primate model of impaired spiral artery remodeling.

Authors:  O M Turan; J S Babischkin; G W Aberdeen; S Turan; C R Harman; G J Pepe; E D Albrecht
Journal:  Ultrasound Obstet Gynecol       Date:  2022-03       Impact factor: 8.678

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.