Literature DB >> 19785446

Simulation of ion motion in FAIMS through combined use of SIMION and modified SDS.

Satendra Prasad1, Keqi Tang, David Manura, Dimitris Papanastasiou, Richard D Smith.   

Abstract

A key application of field asymmetric waveform ion mobility spectrometry (FAIMS) has been in selectively transmitting trace analyte ions that are present in a complex ion mixture to a mass spectrometer (MS) for identification and quantification. The overall sensitivity of FAIMS-MS, however, still needs to be significantly improved through the optimization of ion transmission into FAIMS and at the FAIMS-MS interface. Processes that cause ion losses include diffusion, space charge, separation field in the FAIMS and fringe fields around the edges of the FAIMS electrodes. These were studied here by first developing an algorithm using SIMION as its core structure to compute ion trajectory at different ratios of electric field to buffer gas number density (E/N). The E/N was varied from a few Td to approximately 80 Td by using an asymmetric square waveform. The algorithm was then combined with statistical diffusion simulation (SDS) model, columbic repulsion, and a parabolic gas flow profile to realistically simulate current transmission and peak shape. The algorithm was validated using a FAIMS model identical to the Sionex Corporation SVAC model. Ions modeled included low mass ions with K(o) in the range of 2.17 (m = 55) to 1.39 cm(2) x V(-1) x s(-1) (m = 368). Good agreement was achieved between simulated and experimental CV (peak maxima) values, peak width (fwhm), and transmitted ion current I(output). The model was then used to study fringe fields in a simple arrangement where a 0.5 mm (w) gap was created between the FAIMS exit and a capillary inlet (i.d. = 0.5 mm). At an optimum CV (11.8 V), only approximately 17% (1.3 pA) of the total ion current that correlate to CV = 11.8 V, entered the capillary; bulk of the ion loss was caused by the fringe fields. Current transmission into the capillary was improved, however, by applying a 500 V DC bias across w (0.5 mm).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19785446      PMCID: PMC2784151          DOI: 10.1021/ac900880v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  23 in total

1.  Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas.

Authors:  G A Eiceman; E V Krylov; N S Krylova; E G Nazarov; R A Miller
Journal:  Anal Chem       Date:  2004-09-01       Impact factor: 6.986

2.  Optimization of the design and operation of FAIMS analyzers.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-01       Impact factor: 3.109

3.  Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Authors:  Keqi Tang; Fumin Li; Alexandre A Shvartsburg; Eric F Strittmatter; Richard D Smith
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

4.  Multidimensional separations of ubiquitin conformers in the gas phase: relating ion cross sections to H/D exchange measurements.

Authors:  Errol W Robinson; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2005-09       Impact factor: 3.109

5.  An IMS-IMS analogue of MS-MS.

Authors:  Stormy L Koeniger; Samuel I Merenbloom; Stephen J Valentine; Martin F Jarrold; Harold R Udseth; Richard D Smith; David E Clemmer
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

6.  Characterizing the structures and folding of free proteins using 2-D gas-phase separations: observation of multiple unfolded conformers.

Authors:  Alexandre A Shvartsburg; Fumin Li; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-05-15       Impact factor: 6.986

7.  Analysis of bacterial strains with pyrolysis-gas chromatography/differential mobility spectrometry.

Authors:  Satendra Prasad; Hartwig Schmidt; Peter Lampen; Mei Wang; Robert Güth; Jaya V Rao; Geoffrey B Smith; Gary A Eiceman
Journal:  Analyst       Date:  2006-09-12       Impact factor: 4.616

Review 8.  Ion mobility-mass spectrometry.

Authors:  Abu B Kanu; Prabha Dwivedi; Maggie Tam; Laura Matz; Herbert H Hill
Journal:  J Mass Spectrom       Date:  2008-01       Impact factor: 1.982

9.  Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry.

Authors:  Brian H Clowers; Yehia M Ibrahim; David C Prior; William F Danielson; Mikhail E Belov; Richard D Smith
Journal:  Anal Chem       Date:  2008-01-01       Impact factor: 6.986

10.  Resolution and structural transitions of elongated states of ubiquitin.

Authors:  Stormy L Koeniger; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2006-11-02       Impact factor: 3.109

View more
  7 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Spatial Ion Peak Compression and its Utility in Ion Mobility Spectrometry.

Authors:  Sandilya V B Garimella; Yehia M Ibrahim; Keqi Tang; Ian K Webb; Erin S Baker; Aleksey V Tolmachev; Tsung-Chi Chen; Gordon A Anderson; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-06       Impact factor: 3.109

Review 3.  Size, weight and position: ion mobility spectrometry and imaging MS combined.

Authors:  András Kiss; Ron M A Heeren
Journal:  Anal Bioanal Chem       Date:  2011-01-13       Impact factor: 4.142

4.  Monte Carlo simulation of ion trajectories of reacting chemical systems: mobility of small water clusters in ion mobility spectrometry.

Authors:  Walter Wissdorf; Luzia Seifert; Valerie Derpmann; Sonja Klee; Wolfgang Vautz; Thorsten Benter
Journal:  J Am Soc Mass Spectrom       Date:  2013-03-02       Impact factor: 3.109

5.  Simulation of electric potentials and ion motion in planar electrode structures for lossless ion manipulations (SLIM).

Authors:  Sandilya V B Garimella; Yehia M Ibrahim; Ian K Webb; Aleksey V Tolmachev; Xinyu Zhang; Spencer A Prost; Gordon A Anderson; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-26       Impact factor: 3.109

6.  On an aerodynamic mechanism to enhance ion transmission and sensitivity of FAIMS for nano-electrospray ionization-mass spectrometry.

Authors:  Satendra Prasad; Michael W Belford; Jean-Jacques Dunyach; Randy W Purves
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-30       Impact factor: 3.109

7.  Ion manipulations in structures for lossless ion manipulations (SLIM): computational evaluation of a 90° turn and a switch.

Authors:  Sandilya V B Garimella; Yehia M Ibrahim; Ian K Webb; Andreas B Ipsen; Tsung-Chi Chen; Aleksey V Tolmachev; Erin S Baker; Gordon A Anderson; Richard D Smith
Journal:  Analyst       Date:  2015-10-21       Impact factor: 4.616

  7 in total