Literature DB >> 19784644

Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach.

Gokhan Gokalp1, Abdurrahim Dusak, Zeynep Yazici.   

Abstract

AIM: Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint.
MATERIALS AND METHODS: Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection.
RESULTS: One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minör muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse.
CONCLUSION: Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19784644     DOI: 10.1007/s00256-009-0793-8

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  10 in total

1.  MR arthrography of the shoulder: fluoroscopically guided technique using a posterior approach.

Authors:  K D Farmer; P M Hughes
Journal:  AJR Am J Roentgenol       Date:  2002-02       Impact factor: 3.959

2.  MR arthrography of the glenohumeral joint: a tailored approach.

Authors:  C B Chung; J R Dwek; S Feng; D Resnick
Journal:  AJR Am J Roentgenol       Date:  2001-07       Impact factor: 3.959

Review 3.  Aspiration and injection therapies for joints.

Authors:  H Ralph Schumacher
Journal:  Arthritis Rheum       Date:  2003-06-15

4.  Sonographically guided glenohumeral joint injection.

Authors:  Richard B Zwar; John W Read; Jennifer B Noakes
Journal:  AJR Am J Roentgenol       Date:  2004-07       Impact factor: 3.959

5.  Ultrasonography-guided contrast media injection to shoulder joint using a posterior approach: a technique worth trying.

Authors:  H Vierola
Journal:  Acta Radiol       Date:  2004-10       Impact factor: 1.990

6.  MR arthrography of the glenohumeral joint: modified posterior approach without imaging guidance.

Authors:  Onofrio A Catalano; Riccardo Manfredi; Angelo Vanzulli; Ernesto Tomei; Marcelo Napolitano; Andrea Esposito; Donald Resnick
Journal:  Radiology       Date:  2007-02       Impact factor: 11.105

7.  Sonographic guidance of needle position for MR arthrography of the shoulder.

Authors:  R Valls; P Melloni
Journal:  AJR Am J Roentgenol       Date:  1997-09       Impact factor: 3.959

8.  Ultrasonographic guidance of needle placement for shoulder arthrography.

Authors:  N Cicak; T Matasović; T Bajraktarević
Journal:  J Ultrasound Med       Date:  1992-04       Impact factor: 2.153

9.  Shoulder magnetic resonance arthrography: a prospective randomized study of anterior and posterior ultrasonography-guided contrast injections.

Authors:  M P Koivikko; A O T Mustonen
Journal:  Acta Radiol       Date:  2008-10       Impact factor: 1.990

10.  MR arthrography of the shoulder using an anterior approach: optimal injection site.

Authors:  María V Redondo; Juan D Berná-Serna; Pedro A Campos; Manuel Reus; Francisco Martínez; Matilde Campos; Ernesto Domenech
Journal:  AJR Am J Roentgenol       Date:  2008-11       Impact factor: 3.959

  10 in total
  11 in total

1.  Ultrasound guidance improves the accuracy of the acromioclavicular joint infiltration: a prospective randomized study.

Authors:  Manuel Sabeti-Aschraf; B Lemmerhofer; S Lang; M Schmidt; P T Funovics; P Ziai; S Frenzel; A Kolb; A Graf; C Schueller-Weidekamm
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-19       Impact factor: 4.342

Review 2.  Ultrasound-guided joint injections for MR arthrography in pediatric patients: how we do it.

Authors:  Jeffrey Otjen; Shawn E Parnell; Sarah Menashe; Mahesh M Thapa
Journal:  Pediatr Radiol       Date:  2015-03-01

3.  Extra-articular contrast material leaks into locations unrelated to the injection path in shoulder MR arthrography.

Authors:  Hayri Ogul; Mecit Kantarci; Murat Topal; Leyla Karaca; Kutsi Tuncer; Berhan Pirimoglu; Aylin Okur; Omer Selim Yildirim; Akin Levent
Journal:  Eur Radiol       Date:  2014-06-25       Impact factor: 5.315

4.  Clinical indications for image-guided interventional procedures in the musculoskeletal system: a Delphi-based consensus paper from the European Society of Musculoskeletal Radiology (ESSR)-part I, shoulder.

Authors:  Luca Maria Sconfienza; Miraude Adriaensen; Domenico Albano; Georgina Allen; Maria Pilar Aparisi Gómez; Alberto Bazzocchi; Ian Beggs; Bianca Bignotti; Vito Chianca; Angelo Corazza; Danoob Dalili; Miriam De Dea; Jose Luis Del Cura; Francesco Di Pietto; Eleni Drakonaki; Fernando Facal de Castro; Dimitrios Filippiadis; Jan Gielen; Salvatore Gitto; Harun Gupta; Andrea S Klauser; Radhesh Lalam; Silvia Martin; Carlo Martinoli; Giovanni Mauri; Catherine McCarthy; Eugene McNally; Kalliopi Melaki; Carmelo Messina; Rebeca Mirón Mombiela; Benedikt Neubauer; Cyprian Olchowy; Davide Orlandi; Athena Plagou; Raquel Prada Gonzalez; Saulius Rutkauskas; Ziga Snoj; Alberto Stefano Tagliafico; Alexander Talaska; Violeta Vasilevska-Nikodinovska; Jelena Vucetic; David Wilson; Federico Zaottini; Marcello Zappia; Marina Obradov
Journal:  Eur Radiol       Date:  2019-09-16       Impact factor: 5.315

5.  A prospective randomized study comparing three different approaches to fluoroscopy-guided shoulder arthrography according to the experience of practitioners.

Authors:  Guen Young Lee; Joon Woo Lee; Eugene Lee; Joong Mo Ahn; Heung Sik Kang
Journal:  Skeletal Radiol       Date:  2017-04-01       Impact factor: 2.199

Review 6.  Are blind injections of gleno-humeral joint (GHJ) really less accurate imaging-guided injections? A narrative systematic review considering multiple anatomical approaches.

Authors:  Paolo Simoni; Marco Grumolato; Olivier Malaise; Marco Preziosi; Francoise Pasleau; Fréderic de Lemos Esteves
Journal:  Radiol Med       Date:  2017-05-18       Impact factor: 3.469

7.  Magnetic resonance arthrography of the glenohumeral joint: ultrasonography-guided technique using a posterior approach.

Authors:  Hayri Ogul; Ummugulsum Bayraktutan; Omer Selim Yildirim; Selami Suma; Mesut Ozgokce; Adnan Okur; Mecit Kantarci
Journal:  Eurasian J Med       Date:  2012-08

8.  Comparing the accuracy and efficacy of ultrasound-guided versus blind injections of steroid in the glenohumeral joint in patients with shoulder adhesive capsulitis.

Authors:  Seyed Ahmad Raeissadat; Seyed Mansoor Rayegani; Taraneh Faghihi Langroudi; Maryam Khoiniha
Journal:  Clin Rheumatol       Date:  2016-08-26       Impact factor: 2.980

9.  MR arthrography of the shoulder: tolerance evaluation of four different injection techniques.

Authors:  Evangelos Perdikakis; Eleni Drakonaki; Thomas Maris; Apostolos Karantanas
Journal:  Skeletal Radiol       Date:  2012-10-14       Impact factor: 2.199

Review 10.  Ultrasound-guided interventional procedures around the shoulder.

Authors:  Alberto Tagliafico; Giuseppe Russo; Sara Boccalini; Johan Michaud; Andrea Klauser; Giovanni Serafini; Carlo Martinoli
Journal:  Radiol Med       Date:  2013-12-03       Impact factor: 3.469

View more