Literature DB >> 19782219

Simple, rapid, and highly sensitive detection of diphosgene and triphosgene by spectrophotometric methods.

Abraham Joy1, Emmanuel Anim-Danso, Joachim Kohn.   

Abstract

Methods for the detection and estimation of diphosgene and triphosgene are described. These compounds are widely used phosgene precursors which produce an intensely colored purple pentamethine oxonol dye when reacted with 1,3-dimethylbarbituric acid (DBA) and pyridine (or a pyridine derivative). Two quantitative methods are described, based on either UV absorbance or fluorescence of the oxonol dye. Detection limits are approximately 4 micromol/L by UV and <0.4 micromol/L by fluorescence. The third method is a test strip for the simple and rapid detection and semi-quantitative estimation of diphosgene and triphosgene, using a filter paper embedded with dimethylbarbituric acid and poly(4-vinylpyridine). Addition of a test solution to the paper causes a color change from white to light blue at low concentrations and to pink at higher concentrations of triphosgene. The test strip is useful for quick on-site detection of triphosgene and diphosgene in reaction mixtures. The test is easy to perform and provides clear signal readouts indicative of the presence of phosgene precursors. The utility of this method was demonstrated by the qualitative determination of residual triphosgene during the production of poly(bisphenol-A carbonate).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19782219      PMCID: PMC2757637          DOI: 10.1016/j.talanta.2009.06.059

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  11 in total

1.  A FRET approach to phosgene detection.

Authors:  Hexiang Zhang; Dmitry M Rudkevich
Journal:  Chem Commun (Camb)       Date:  2007-01-12       Impact factor: 6.222

2.  Fluorescent sensors for the detection of chemical warfare agents.

Authors:  Mark Burnworth; Stuart J Rowan; Christoph Weder
Journal:  Chemistry       Date:  2007       Impact factor: 5.236

3.  Diagnostic efficiency of home pregnancy test kits. A meta-analysis.

Authors:  L A Bastian; K Nanda; V Hasselblad; D L Simel
Journal:  Arch Fam Med       Date:  1998 Sep-Oct

4.  Pulmonary structural and extracellular matrix alterations in Fischer 344 rats following subchronic phosgene exposure.

Authors:  U P Kodavanti; D L Costa; S N Giri; B Starcher; G E Hatch
Journal:  Fundam Appl Toxicol       Date:  1997-05

5.  Assessment of five portable blood glucose meters, a point-of-care analyzer, and color test strips for measuring blood glucose concentration in dogs.

Authors:  L A Cohn; D L McCaw; D J Tate; J C Johnson
Journal:  J Am Vet Med Assoc       Date:  2000-01-15       Impact factor: 1.936

6.  Identification and colorimetric determination of organic cyanates in nanomolar quantities.

Authors:  J Kohn; E C Albert; M Wilchek; R Langer
Journal:  Anal Chem       Date:  1986-12       Impact factor: 6.986

7.  A spectrophotometric method for determination of phosgene in air.

Authors:  S K Dangwal
Journal:  Ind Health       Date:  1994       Impact factor: 2.179

8.  A highly sensitive colorimetric method for the determination of carbodiimides.

Authors:  M Wilchek; T Miron; J Kohn
Journal:  Anal Biochem       Date:  1981-07-01       Impact factor: 3.365

9.  Tyrosine-derived polycarbonates: backbone-modified "pseudo"-poly (amino acids) designed for biomedical applications.

Authors:  S Pulapura; J Kohn
Journal:  Biopolymers       Date:  1992-04       Impact factor: 2.505

10.  Analysis of chemical warfare agents III. Use of bis-nucleophiles in the trace level determination of phosgene and perfluoroisobutylene.

Authors:  Bob Muir; David B Cooper; Wendy A Carrick; Christopher M Timperley; Ben J Slater; Suzanne Quick
Journal:  J Chromatogr A       Date:  2005-10-05       Impact factor: 4.759

View more
  1 in total

1.  Inclusive DFT insight into sensing mechanism of cyclotetrapyrole towards lung irritants.

Authors:  Saif Ullah; Haleema Sadia; Faizan Ullah; Tabish Jadoon
Journal:  J Mol Model       Date:  2022-04-02       Impact factor: 1.810

  1 in total