Literature DB >> 19782201

Determination and interference studies of bismuth by tungsten trap hydride generation atomic absorption spectrometry.

Ibrahim Kula1, Yasin Arslan, Sezgin Bakirdere, Serap Titretir, Erdal Kendüzler, O Yavuz Ataman.   

Abstract

The determination of bismuth requires sufficiently sensitive procedures for detection at the microg L(-1) level or lower. W-coil was used for on-line trapping of volatile bismuth species using HGAAS (hydride generation atomic absorption spectrometry); atom trapping using a W-coil consists of three steps. Initially BiH(3) gas is formed by hydride generation procedure. The analyte species in vapor form are transported through the W-coil trap held at 289 degrees C where trapping takes place. Following the preconcentration step, the W-coil is heated to 1348 degrees C; analyte species are released and transported to flame-heated quartz atom cell where the atomic signal is formed. In our study, interferences have been investigated in detail during Bi determination by hydride generation, both with and without trap in the same HGAAS system. Interferent/analyte (mass/mass) ratio was kept at 1, 10 and 100. Experiments were designed for carrier solutions having 1.0M HNO(3). Interferents such as Fe, Mn, Zn, Ni, Cu, As, Se, Cd, Pb, Au, Na, Mg, Ca, chloride, sulfate and phosphate were examined. The calibration plot for an 8.0 mL sampling volume was linear between 0.10 microg L(-1) and 10.0 microg L(-1) of Bi. The detection limit (3s/m) was 25 ng L(-1). The enhancement factor for the characteristic concentration (C(o)) was found to be 21 when compared with the regular system without trap, by using peak height values. The validation of the procedure was performed by the analysis of the certified water reference material and the result was found to be in good agreement with the certified values at the 95% confidence level.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19782201     DOI: 10.1016/j.talanta.2009.06.084

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Determination of bismuth in environmental samples by slurry sampling graphite furnace atomic absorption spectrometry using combined chemical modifiers.

Authors:  Ryszard Dobrowolski; Joanna Dobrzyńska; Barbara Gawrońska
Journal:  Environ Monit Assess       Date:  2014-11-12       Impact factor: 2.513

2.  A Simple, Fast, and Inexpensive Simultaneous Determination of Trace Bismuth(III) and Lead(II) in Water Samples by Adsorptive Stripping Voltammetry.

Authors:  Malgorzata Grabarczyk; Marzena Adamczyk
Journal:  J Anal Methods Chem       Date:  2017-08-28       Impact factor: 2.193

3.  Dispersive Liquid-Liquid Microextraction of Bismuth in Various Samples and Determination by Flame Atomic Absorption Spectrometry.

Authors:  Teslima Daşbaşı; Şenol Kartal; Şerife Saçmacı; Ahmet Ülgen
Journal:  J Anal Methods Chem       Date:  2016-01-11       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.