Literature DB >> 19780179

SENSE shimming (SSH): A fast approach for determining B(0) field inhomogeneities using sensitivity coding.

D N Splitthoff1, M Zaitsev.   

Abstract

The pursuit of ever higher field strengths and faster data acquisitions has led to the construction of coil arrays with high numbers of elements. With the sensitivity encoding (SENSE) technique, it has been shown that the sensitivity of those elements can be used for spatial image encoding. Here, a proof-of-principle is presented of a method that can be considered an extreme case of the SENSE approach, completely abstaining from using encoding gradients. The resulting sensitivity encoded free-induction decay (FID) data are then not used for imaging, but for determining B(0) field inhomogeneity distribution. The method has therefore been termed "SENSE shimming" (SSH). In phantom experiments the method's ability to detect inhomogeneities of up to the second order is demonstrated. (c) 2009 Wiley-Liss, Inc.

Mesh:

Year:  2009        PMID: 19780179     DOI: 10.1002/mrm.22083

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Head motion measurement and correction using FID navigators.

Authors:  Tess E Wallace; Onur Afacan; Maryna Waszak; Tobias Kober; Simon K Warfield
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

2.  Spectroscopic imaging with prospective motion correction and retrospective phase correction.

Authors:  Thomas Lange; Julian Maclaren; Martin Buechert; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

Review 3.  Motion correction in MRI of the brain.

Authors:  F Godenschweger; U Kägebein; D Stucht; U Yarach; A Sciarra; R Yakupov; F Lüsebrink; P Schulze; O Speck
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

4.  Rapid measurement and correction of spatiotemporal B0 field changes using FID navigators and a multi-channel reference image.

Authors:  Tess E Wallace; Onur Afacan; Tobias Kober; Simon K Warfield
Journal:  Magn Reson Med       Date:  2019-08-29       Impact factor: 4.668

5.  Real-time shimming with FID navigators.

Authors:  Tess E Wallace; Tobias Kober; Jason P Stockmann; Jonathan R Polimeni; Simon K Warfield; Onur Afacan
Journal:  Magn Reson Med       Date:  2022-09-12       Impact factor: 3.737

6.  Dynamic distortion correction for functional MRI using FID navigators.

Authors:  Tess E Wallace; Jonathan R Polimeni; Jason P Stockmann; W Scott Hoge; Tobias Kober; Simon K Warfield; Onur Afacan
Journal:  Magn Reson Med       Date:  2020-09-24       Impact factor: 4.668

7.  Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses.

Authors:  Fuyixue Wang; Zijing Dong; Lawrence L Wald; Jonathan R Polimeni; Kawin Setsompop
Journal:  Neuroimage       Date:  2021-10-13       Impact factor: 6.556

8.  Model-based dynamic off-resonance correction for improved accelerated fMRI in awake behaving nonhuman primates.

Authors:  Mo Shahdloo; Urs Schüffelgen; Daniel Papp; Karla L Miller; Mark Chiew
Journal:  Magn Reson Med       Date:  2022-01-26       Impact factor: 3.737

  8 in total