Literature DB >> 19780174

Improved signal spoiling in fast radial gradient-echo imaging: Applied to accurate T(1) mapping and flip angle correction.

Wei Lin1, Hee Kwon Song.   

Abstract

In conventional spoiled gradient echo imaging utilizing quadratic radio frequency (RF) spoiling, nonideal signal intensities are often generated, particularly when repetition time is short and/or excitation flip angle (FA) becomes larger. This translates to significant errors in various quantitative applications based on T(1)-weighted image intensities. In this work, a novel spoiling scheme is proposed, based on random gradient moments and RF phases. This scheme results in a non-steady-state condition, but achieves ideal mean signal intensity. In order to suppress artifacts created by the inter-TR signal variations and at the same time attain the ideal signal intensity, radial data acquisition is utilized. The proposed method achieves ideal spoiling for a wide range of T(1), T(2), TR, and FAs. Phantom and in vivo experiments demonstrate improved performance for T(1) mapping and FA correction when compared with conventional RF spoiling methods. (c) 2009 Wiley-Liss, Inc.

Mesh:

Year:  2009        PMID: 19780174     DOI: 10.1002/mrm.22089

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

Review 1.  Quantitative relaxometry of the brain.

Authors:  Sean C L Deoni
Journal:  Top Magn Reson Imaging       Date:  2010-04

2.  Motion correction for myocardial T1 mapping using image registration with synthetic image estimation.

Authors:  Hui Xue; Saurabh Shah; Andreas Greiser; Christoph Guetter; Arne Littmann; Marie-Pierre Jolly; Andrew E Arai; Sven Zuehlsdorff; Jens Guehring; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

3.  Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence.

Authors:  Liyong Chen; Ganesh Adluru; Matthias C Schabel; Chris J McGann; Edward V R Dibella
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

4.  Steady-state double-angle method for rapid B1 mapping.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2019-03-03       Impact factor: 4.668

5.  Four-angle method for practical ultra-high-resolution magnetic resonance mapping of brain longitudinal relaxation time and apparent proton density.

Authors:  Mustapha Bouhrara; Abinand C Rejimon; Luis E Cortina; Nikkita Khattar; Richard G Spencer
Journal:  Magn Reson Imaging       Date:  2019-11-12       Impact factor: 2.546

6.  Flip angle mapping with the accelerated 3D look-locker sequence.

Authors:  Trevor Wade; Charles A McKenzie; Brian K Rutt
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

7.  B1 mapping of short T2 * spins using a 3D radial gradient echo sequence.

Authors:  Naoharu Kobayashi; Michael Garwood
Journal:  Magn Reson Med       Date:  2013-06-10       Impact factor: 4.668

8.  Optimizing trajectory ordering for fast radial ultra-short TE (UTE) acquisitions.

Authors:  Xucheng Zhu; Fei Tan; Kevin Johnson; Peder Larson
Journal:  J Magn Reson       Date:  2021-04-02       Impact factor: 2.734

9.  Time Efficient 3D Radial UTE Sampling with Fully Automatic Delay Compensation on a Clinical 3T MR Scanner.

Authors:  Karl-Heinz Herrmann; Martin Krämer; Jürgen R Reichenbach
Journal:  PLoS One       Date:  2016-03-14       Impact factor: 3.240

10.  Hexagonal gradient scheme with RF spoiling improves spoiling performance for high-flip-angle fast gradient echo imaging.

Authors:  Aaron T Hess; Matthew D Robson
Journal:  Magn Reson Med       Date:  2016-04-01       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.