Abstract

Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

Entities:  

Mesh:

Year:  2009        PMID: 19779282     DOI: 10.2176/nmc.49.386

Source DB:  PubMed          Journal:  Neurol Med Chir (Tokyo)        ISSN: 0470-8105            Impact factor:   1.742


  7 in total

1.  New ischemic brain lesions on diffusion-weighted MRI after carotid artery stenting with filter protection: frequency and relationship with plaque morphology.

Authors:  D Stojanov; M Ilic; P Bosnjakovic; M Zivkovic; S Jolic; N Vukasinovic; A Ignjatovic; B Ilic; D Benedeto-Stojanov
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-22       Impact factor: 3.825

2.  Safety of carotid artery stenting for elderly patients with cervical carotid artery stenosis.

Authors:  Akira Taguchi; Shigeyuki Sakamoto; Takahito Okazaki; Jumpei Oshita; Masashi Kuwabara; Kaoru Kurisu
Journal:  Interv Neuroradiol       Date:  2020-01-22       Impact factor: 1.610

3.  Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon.

Authors:  Minoru Iko; Masanori Tsutsumi; Hiroshi Aikawa; Yoshihisa Matsumoto; Yoshinori Go; Kouhei Nii; Gorou Abe; Iwae Ye; Yasuyuki Nomoto; Kiyoshi Kazekawa
Journal:  Jpn J Radiol       Date:  2012-11-20       Impact factor: 2.374

4.  Silent brain infarcts on diffusion-weighted imaging after carotid revascularisation: A surrogate outcome measure for procedural stroke? A systematic review and meta-analysis.

Authors:  Christopher Traenka; Stefan T Engelter; Martin M Brown; Joanna Dobson; Chris Frost; Leo H Bonati
Journal:  Eur Stroke J       Date:  2019-01-15

5.  Complications and Predictors of Hypotension Requiring Vasopressor after Carotid Artery Stenting.

Authors:  Masataka Nanto; Yudai Goto; Hiroyuki Yamamoto; Seisuke Tanigawa; Hayato Takeuchi; Yoshikazu Nakahara; Hiroshi Tenjin; Michiko Takado
Journal:  Neurol Med Chir (Tokyo)       Date:  2017-01-31       Impact factor: 1.742

6.  Anti-embolism devices therapy to improve the ICU mortality rate of patients with acute myocardial infarction and type II diabetes mellitus.

Authors:  Xiaxuan Huang; Luming Zhang; Mengyuan Xu; Shiqi Yuan; Yan Ye; Tao Huang; Haiyan Yin; Jun Lyu
Journal:  Front Cardiovasc Med       Date:  2022-07-19

7.  Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting.

Authors:  Jong Hyeok Lee; Hee Eon Sohn; Seung Young Chung; Moon Sun Park; Seong Min Kim; Do Sung Lee
Journal:  J Korean Neurosurg Soc       Date:  2015-10-30
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.