Literature DB >> 19778877

Application of the 3-vessel view in routine prenatal sonographic screening for congenital heart disease.

Qingqing Wu1, Man Li, Lirong Ju, Weiyuan Zhang, Xinghua Yang, Yuxiang Yan, Wei Wang.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate the diagnostic accuracy of prenatal screening for congenital heart disease (CHD) based on a combination of the 4-chamber view and 3-vessel view in an unselected population.
METHODS: A prospective study on 8025 scanned fetuses was performed. All singleton pregnancies scheduled for routine prenatal sonographic screening at 20 to 24 weeks' gestation and subsequently delivered in our unit were included. Data were recorded regarding visualization of the 4-chamber view, outflow tracts, and 3-vessel view. Suspected CHD was confirmed by postmortem or postnatal echocardiography. We obtained follow-up data for the neonates and calculated the diagnostic accuracy of the examinations.
RESULTS: Major CHD was identified in 32 cases (4.0%), of which 26 (81.3%) were diagnosed antenatally and 6 (18.7%) postnatally. Four cases (0.5%) had false-positive findings. Twenty-one cases were identified by the 4-chamber view and 5 by an abnormal 3-vessel view. The sensitivity of the 4-chamber view alone was 65.6%, and the specificity was 99.9%. The sensitivity of the combination of the 4-chamber view and 3-vessel view was 81.3%, and the specificity was 99.9%.
CONCLUSIONS: The 3-vessel view is a reliable and easy method to be used in a routine antenatal clinic along with the 4-chamber view.

Entities:  

Mesh:

Year:  2009        PMID: 19778877     DOI: 10.7863/jum.2009.28.10.1319

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Normal ranges for fetal electrocardiogram values for the healthy fetus of 18-24 weeks of gestation: a prospective cohort study.

Authors:  Kim M J Verdurmen; Carlijn Lempersz; Rik Vullings; Christian Schroer; Tammo Delhaas; Judith O E H van Laar; S Guid Oei
Journal:  BMC Pregnancy Childbirth       Date:  2016-08-17       Impact factor: 3.007

2.  Performance of different scan protocols of fetal echocardiography in the diagnosis of fetal congenital heart disease: a systematic review and meta-analysis.

Authors:  Yifei Li; Yimin Hua; Jie Fang; Chuan Wang; Lina Qiao; Chaomin Wan; Dezhi Mu; Kaiyu Zhou
Journal:  PLoS One       Date:  2013-06-04       Impact factor: 3.240

Review 3.  Diagnostic Value of Fetal Echocardiography for Congenital Heart Disease: A Systematic Review and Meta-Analysis.

Authors:  Ya-Fei Zhang; Xian-Ling Zeng; En-Fa Zhao; Hong-Wei Lu
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.