Literature DB >> 19776082

Air-leak management after upper lobectomy in patients with fused fissure and chronic obstructive pulmonary disease: a pilot trial comparing sealant and standard treatment.

Ottavio Rena1, Esther Papalia, Tommaso Claudio Mineo, Fabio Massera, Emanuele Pirondini, Davide Turello, Caterina Casadio.   

Abstract

A pilot trial to compare the efficacy of two different procedures to prevent postoperative air-leak in chronic obstructive pulmonary disease (COPD) patients submitted to upper lobectomy for non-small cell lung cancer. Sixty patients with COPD and lung cancer at the upper pulmonary lobes eligible for lobectomy were enrolled and randomly assigned either to standard treatment (ST) with stapling device or to electrocautery dissection and application of a collagen patch coated with human fibrinogen and thrombin (TachoSil) (experimental treatment [ET]) for the intra-operative completion of their fused fissures. Thirty patients were enrolled in each group during a three-year period. Preoperative characteristics were similar between the two groups. Statistically significant reduction of air-leak was registered in the ET group when overall incidence of postoperative air-leak (55% vs. 96%; P=0.03), postoperative air-leak (mean 1.63+/-1.96 vs. 4.33+/-4.12 days; P=0.0018), chest-drain (mean 3.53+/-1.59 vs. 5.90+/-3.72 days; P=0.0021) and hospital stay duration (mean 5.87+/-1.07 vs. 7.50+/-3.20 days; P=0.01) were considered. The use of TachoSil to prevent postoperative air-leak after interlobar fissure completion in patients with COPD submitted to upper lobectomy seems to be safe and more effective than the ST based on stapling device application.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19776082     DOI: 10.1510/icvts.2009.202770

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  13 in total

1.  A prospective randomized trial comparing stapler and laser techniques for interlobar fissure completion during pulmonary lobectomy.

Authors:  Giuseppe Marulli; Andrea Droghetti; Francesco Di Chiara; Francesca Calabrese; Alessandro Rebusso; Egle Perissinotto; Giovanni Muriana; Federico Rea
Journal:  Lasers Med Sci       Date:  2012-04-24       Impact factor: 3.161

2.  Efficacy of TachoSil, a Fibrin-Based Hemostat, for Anterior Lumbar Spine Surgery.

Authors:  Jo Watanabe; Seiji Ohtori; Sumihisa Orita; Kazuyo Yamauchi; Yawara Eguchi; Yasuchika Aoki; Junichi Nakamura; Miyako Suzuki; Kazuhide Inage; Jun Sato; Yasuhiro Shiga; Koki Abe; Kazuki Fujimoto; Hirohito Kanamoto; Eiji Hanaoka; Kazuhisa Takahashi
Journal:  Asian Spine J       Date:  2016-10-17

3.  Efficacy and safety of human fibrinogen-thrombin patch (TachoSil®) in the treatment of postoperative air leakage in patients submitted to redo surgery for lung malignancies: a randomized trial.

Authors:  Pier Luigi Filosso; Enrico Ruffini; Alberto Sandri; Paolo Olivo Lausi; Roberto Giobbe; Alberto Oliaro
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-02-17

4.  Feedback on the use of three surgical sealants for preventing prolonged air leak after robot-assisted anatomical lung resection.

Authors:  Henri Gondé; Constance Le Gac; André Gillibert; Benjamin Bottet; Marc Laurent; Matthieu Sarsam; Charles Hervouët; Rémi Varin; Jean-Marc Baste
Journal:  J Thorac Dis       Date:  2019-07       Impact factor: 2.895

5.  Acute pneumonitis consequent on pleurodesis with Viscum album extract: severe chest images but benign clinical course.

Authors:  Suk Ju Cho; Su Wan Kim; Jee Won Chang
Journal:  Multidiscip Respir Med       Date:  2014-11-27

6.  Treatment of Esophageal Perforation with Primary Closure and Reinforcement Using TachoSil.

Authors:  Abolghasem Daneshvar Kakhki; Seyed Reza Saghebi; Farahnaz Sadegh Bigee
Journal:  Tanaffos       Date:  2017

7.  Clinical outcomes of polymeric sealant use in pulmonary resection: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Anna L McGuire; John Yee
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

8.  Haemostatic Role of TachoSil Surgical Patch in Cardiac Surgery.

Authors:  Alireza Alizadeh Ghavidel; Yalda Mirmesdagh; Niloufar Samiei; Maziar Gholampour Dehaki
Journal:  J Cardiovasc Thorac Res       Date:  2014-06-30

Review 9.  Economic and outcomes consequences of TachoSil®: a systematic review.

Authors:  Giorgio L Colombo; Daria Bettoni; Sergio Di Matteo; Camilla Grumi; Cinzia Molon; Daniela Spinelli; Gaetano Mauro; Alessia Tarozzo; Giacomo M Bruno
Journal:  Vasc Health Risk Manag       Date:  2014-09-10

Review 10.  Control of bleeding in surgical procedures: critical appraisal of HEMOPATCH (Sealing Hemostat).

Authors:  Kevin Michael Lewis; Carl Erik Kuntze; Heinz Gulle
Journal:  Med Devices (Auckl)       Date:  2015-12-22
View more