Effect of packing density of hollow fibers on solute removal performances of dialyzers.

Akihiro C Yamashita1, Ryoichiro Fujita, Narumi Tomisawa, Yoichi Jinbo, Masaru Yamamura.   

Abstract

Solute removal performances of dialyzers are dependent not only on the solute permeabilities of the membrane but also on the module design. We have investigated how the packing density of hollow fiber (PDF) affects the solute removal performances. A series of 4 polyester polymer alloy membrane test dialyzers were assembled with varying PDFs of 29.6%, 35.3%, 44.1%, and 53.1%. Clearances (C(L)) were measured in vitro for creatinine (MW113), vitamin B(12) (MW1355), and chymotrypsin (MW25300) with various Q(B)=100 to 400 and Q(D)=350 to 650 mL/min in the absence of net ultrafiltration. When Q(B) was <or=300 mL/min, no significant changes were found in creatinine C(L) with the increase of PDF up to 35.3%. A slightly greater increase was found in C(L) when Q(B)=400 mL/min. Clearances for vitamin B(12), however, increased with the increase of PDF in the range of 29.6% to 35.3%. The effects of PDF on C(L) were greater with larger Q(B). More importantly, an abrupt increase of C(L) was found when PDF was increased from 44.1% to 53.1%. According to a rigorous mathematical model, this may be caused by the internal filtration, which is reverse ultrafiltration occurring in a dialyzer at any given time. No significant increase was found in chymotrypsin C(L) when the PDF was <or=35.3%, which suggested that C(L) for large molecules was strongly dependent on the solute permeability rather than the conditions of flow patterns. A very steep increase was also found in C(L) for chymotrypsin when the PDF was >44.1%, which was also considered to be due to the internal filtration. Packing density of hollow fiber can be optimized in terms of solute removal performances when the target solute and therapeutic conditions are specified.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19775420     DOI: 10.1111/j.1542-4758.2009.00411.x

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  4 in total

1.  Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities.

Authors:  Ayaka Hirano; Shoko Kida; Ken-ichiro Yamamoto; Kiyotaka Sakai
Journal:  J Artif Organs       Date:  2011-11-25       Impact factor: 1.731

2.  Replication of fouling in vitro in hollow fiber dialyzers by albumin immobilization.

Authors:  Takayoshi Kiguchi; Narumi Tomisawa; Akihiro C Yamashita
Journal:  J Artif Organs       Date:  2022-02-11       Impact factor: 1.731

3.  Novel substitution technique in intermittent infusion hemodiafiltration (I-HDF) therapy using back filtration as substitution.

Authors:  Masaya Watanabe; Takayoshi Kiguchi; Akihiro C Yamashita
Journal:  J Artif Organs       Date:  2022-03-18       Impact factor: 1.731

4.  Effect of Membrane Surface Area on Solute Removal Performance of Dialyzers with Fouling.

Authors:  Takayoshi Kiguchi; Hiromi Ito; Akihiro C Yamashita
Journal:  Membranes (Basel)       Date:  2022-07-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.