OBJECTIVE: The European System for Cardiac Operative Risk Evaluation (EuroSCORE) calculator performance in 30-day outcome prediction after isolated aortic valve replacement (AVR) was evaluated to assess its absolute reliability and usefulness as selection criteria to percutaneous aortic valve implantation (PAVI).
METHODS: We carried out a retrospective statistical analysis on 379 patients (group 0) consecutively submitted to isolated AVR in the past 10 years of surgical activity. We discriminated two periods of 5 years each, so we considered two subgroups of patients: group 1 (200 patients operated during 1999-2003); group 2 (179 patients operated during 2004-2008). We used receiver operating characteristics (ROC) curves for discriminatory power analysis. Model calibration was evaluated with the Hosmer-Lemeshow goodness-of-fit test and Pseudo R(2) analysis.
RESULTS: The overall expected mortality rate at the logistic calculator was 9.37% compared with an observed 10-year mortality of 5.2% (p=0.006). Absolute risk prediction in group 1 fitted the observed outcome (p=0.24) while expected mortality in group 2 was significantly higher than observed (p=0.005). Applying threshold values used as PAVI selection criteria (logistic EuroSCORE >20 or >15), against 29% and 24.3% expected mortality rate, respectively, we registered a significant difference in the observed values (11.4%, p=0.022; 8.6%, p=0.005, respectively). The Hosmer-Lemeshow test demonstrated a lack of model fit in the overall group (p=0.019). ROC analysis revealed a sufficient discriminatory power for either total population (logistic area under curve (AUROC) 0.706; 95% confidence interval (CI): 0.604-0.809; p=0.002) and group 1 (logistic AUROC 0.752; 95% CI: 0.643-0.860; p=0.002). Group 2 showed a lack of risk stratification (logistic AUROC 0.613; 95% CI: 0.401-0.824; p=0.348).
CONCLUSIONS: EuroSCORE appears to be an invalid model in absolute and relative risk prediction for isolated AVR. On this basis, its use in selecting candidates to PAVI should be carefully weighted. Correct stratification and sufficient calibration of absolute risk estimate of high-risk patients are, therefore, mandatory in the aim of assigning those patients who show risk factors really responsible for the worst surgical outcome to new techniques. The goal should be reached by exploring the weight of each independent predictor of death in each single institution involved in PAVI procedures, evaluating local surgical results in terms of absolute risk and analysing those variables significantly affecting relative risk. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19767216     DOI: 10.1016/j.ejcts.2009.08.025

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  3 in total

1.  Outcome after valve surgery in octogenarians and efficacy of early mobilization with early cardiac rehabilitation.

Authors:  Kunihide Nakamura; Eisaku Nakamura; Katsuhiko Niina; Kazushi Kojima
Journal:  Gen Thorac Cardiovasc Surg       Date:  2010-12-18

2.  ESC Working Group on Valvular Heart Disease Position Paper: assessing the risk of interventions in patients with valvular heart disease.

Authors:  Raphael Rosenhek; Bernard Iung; Pilar Tornos; Manuel J Antunes; Bernard D Prendergast; Catherine M Otto; Arie Pieter Kappetein; Janina Stepinska; Jens J Kaden; Christoph K Naber; Esmeray Acartürk; Christa Gohlke-Bärwolf
Journal:  Eur Heart J       Date:  2011-03-15       Impact factor: 29.983

Review 3.  [Transcatheter aortic valve implantation (TAVI): Current perspectives].

Authors:  Luise Gaede; Helge Möllmann
Journal:  Herz       Date:  2015-08       Impact factor: 1.443

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.