Literature DB >> 19766499

Very late thrombosis in a patient with a drug-eluting stent for intracranial atherosclerotic stenosis.

Qinghai Huang1, Bo Hong, Yi Xu, Jianmin Liu.   

Abstract

Late stent thrombosis is an infrequent, but severe, complication after implantation of a drug-eluting stent. We report one such patient, a 69-year-old man with intracranial vertebral artery stenosis. He experienced very late stent thrombosis after discontinuation of clopidogrel therapy, about 16 months after the insertion of a Taxus Stent (Boston Scientific Corporation, Natick, MA, USA). The patient recovered well, with good clinical outcome, after the re-initiation of dual antiplatelet and anticoagulation therapy. No abnormality within the stent was identified on a repeat angiogram taken 4 weeks after treatment re-initiation.

Entities:  

Mesh:

Year:  2009        PMID: 19766499     DOI: 10.1016/j.jocn.2009.01.025

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  2 in total

1.  Impact of cystatin C levels on infarct size and hemorrhage volume in acute cerebral stroke.

Authors:  Dongfang Xiao; Hailong Liu; Hong Zhang; Yumin Luo
Journal:  J Neurol       Date:  2012-02-18       Impact factor: 4.849

Review 2.  Association Between Cystatin C and the Risk of Ischemic Stroke: a Systematic Review and Meta-analysis.

Authors:  Yan Wang; Wei Li; Jun Yang; Mijuan Zhang; Chun'e Tian; Minjiang Ma; Qian Zhang
Journal:  J Mol Neurosci       Date:  2019-07-17       Impact factor: 3.444

  2 in total