Literature DB >> 19760146

A controllably anisotropic conductivity or diffusion phantom constructed from isotropic layers.

Rosalind J Sadleir1, Farida Neralwala, Tang Te, Aaron Tucker.   

Abstract

Phantoms with controllable and well-defined anisotropy are needed to test methods for imaging electrical anisotropy. We developed and tested a phantom that had properties similar to a homogeneous anisotropic conductive medium. The phantom was constructed with alternate slices of isotropic gel having different conductivities. The degree of anisotropy in the phantom could be varied easily by changing the relative conductivity of the two gels. We tested the stability of several phantoms and found their properties were maintained for approximately 8 h following construction. The phantom has application to electrical impedance tomography, magnetic resonance electrical impedance tomography, EEG and ECG source imaging and diffusion tensor imaging.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19760146      PMCID: PMC2809807          DOI: 10.1007/s10439-009-9799-6

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  21 in total

1.  Effects of sample geometry and electrode configuration on measured electrical resistivity of skeletal muscle.

Authors:  S Kun; R Peura
Journal:  IEEE Trans Biomed Eng       Date:  2000-02       Impact factor: 4.538

2.  Conductivity tensor mapping of the human brain using diffusion tensor MRI.

Authors:  D S Tuch; V J Wedeen; A M Dale; J S George; J W Belliveau
Journal:  Proc Natl Acad Sci U S A       Date:  2001-09-25       Impact factor: 11.205

Review 3.  Functional imaging with low-resolution brain electromagnetic tomography (LORETA): a review.

Authors:  R D Pascual-Marqui; M Esslen; K Kochi; D Lehmann
Journal:  Methods Find Exp Clin Pharmacol       Date:  2002

4.  Image reconstruction of anisotropic conductivity tensor distribution in MREIT: computer simulation study.

Authors:  Jin Keun Seo; Hyun Chan Pyo; Chunjae Park; Ohin Kwon; Eung Je Woo
Journal:  Phys Med Biol       Date:  2004-09-21       Impact factor: 3.609

5.  Directional differences of impulse spread in trabecular muscle from mammalian heart.

Authors:  L Clerc
Journal:  J Physiol       Date:  1976-02       Impact factor: 5.182

6.  Use of a modified polysaccharide gel in developing a realistic breast phantom for MRI.

Authors:  G P Mazzara; R W Briggs; Z Wu; B G Steinbach
Journal:  Magn Reson Imaging       Date:  1996       Impact factor: 2.546

7.  The specific resistance of biological material--a compendium of data for the biomedical engineer and physiologist.

Authors:  L A Geddes; L E Baker
Journal:  Med Biol Eng       Date:  1967-05

8.  Materials for phantoms for terahertz pulsed imaging.

Authors:  Gillian C Walker; Elizabeth Berry; Stephen W Smye; David S Brettle
Journal:  Phys Med Biol       Date:  2004-11-07       Impact factor: 3.609

9.  Dipole localization in patients with epilepsy using the realistically shaped head model.

Authors:  B J Roth; D Ko; I R von Albertini-Carletti; D Scaffidi; S Sato
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1997-03

10.  EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model.

Authors:  M Rullmann; A Anwander; M Dannhauer; S K Warfield; F H Duffy; C H Wolters
Journal:  Neuroimage       Date:  2008-09-24       Impact factor: 6.556

View more
  4 in total

1.  Quantification of intraventricular hemorrhage with electrical impedance tomography using a spherical model.

Authors:  T Tang; R J Sadleir
Journal:  Physiol Meas       Date:  2011-06-07       Impact factor: 2.833

2.  A robust current pattern for the detection of intraventricular hemorrhage in neonates using electrical impedance tomography.

Authors:  T Tang; Sungho Oh; R J Sadleir
Journal:  Ann Biomed Eng       Date:  2010-03-18       Impact factor: 3.934

3.  Effects of MR parameter changes on the quantification of diffusion anisotropy and apparent diffusion coefficient in diffusion tensor imaging: evaluation using a diffusional anisotropic phantom.

Authors:  Sang Joon Kim; Choong Gon Choi; Jeong Kon Kim; Sung-Cheol Yun; Geon-Ho Jahng; Ha-Kyu Jeong; Eun Ju Kim
Journal:  Korean J Radiol       Date:  2015-02-27       Impact factor: 3.500

4.  Head phantoms for bioelectromagnetic applications: a material study.

Authors:  Alexander Hunold; René Machts; Jens Haueisen
Journal:  Biomed Eng Online       Date:  2020-11-23       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.