Literature DB >> 19759806

Laser-Machined Shape Memory Alloy Sensors for Position Feedback in Active Catheters.

Alexander T Tung, Byong-Ho Park, David H Liang, Günter Niemeyer.   

Abstract

Catheter-based interventions are a form of minimally invasive surgery that can decrease hospitalization time and greatly lower patient morbidity compared to traditional methods. However, percutaneous catheter procedures are hindered by a lack of precise tip manipulation when actuation forces are transmitted over the length of the catheter. Active catheters with local shape-memory-alloy (SMA) actuation can potentially provide the desired manipulation of a catheter tip, but hysteresis makes it difficult to control the actuators. A method to integrate small-volume, compliant sensors on an active catheter to provide position feedback for control would greatly improve the viability of SMA-based active catheters. In this work, we describe the design, fabrication, and performance of resistance-based position sensors that are laser-machined from superelastic SMA tubing. Combining simple material models and rapid prototyping, we can develop sensors of appropriate stiffness and sensitivity with simple modifications in sensor geometry. The sensors exhibit excellent linearity over the operating range and are designed to be easily integrated onto an active catheter substrate.

Entities:  

Year:  2008        PMID: 19759806      PMCID: PMC2598764          DOI: 10.1016/j.sna.2008.03.024

Source DB:  PubMed          Journal:  Sens Actuators A Phys        ISSN: 0924-4247            Impact factor:   3.407


  2 in total

1.  Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation.

Authors:  C Pappone; S Rosanio; G Oreto; M Tocchi; F Gugliotta; G Vicedomini; A Salvati; C Dicandia; P Mazzone; V Santinelli; S Gulletta; S Chierchia
Journal:  Circulation       Date:  2000-11-21       Impact factor: 29.690

2.  Catheter-induced linear lesions in the left atrium in patients with atrial fibrillation: an electroanatomic study.

Authors:  Sabine Ernst; Feifan Ouyang; Felix Löber; Matthias Antz; Karl-Heinz Kuck
Journal:  J Am Coll Cardiol       Date:  2003-10-01       Impact factor: 24.094

  2 in total
  3 in total

1.  Simultaneous Soft Sensing of Tissue Contact Angle and Force for Millimeter-scale Medical Robots.

Authors:  Veaceslav Arabagi; Andrew Gosline; Robert J Wood; Pierre E Dupont
Journal:  IEEE Int Conf Robot Autom       Date:  2013

Review 2.  Review of Neural Network Modeling of Shape Memory Alloys.

Authors:  Rodayna Hmede; Frédéric Chapelle; Yuri Lapusta
Journal:  Sensors (Basel)       Date:  2022-07-27       Impact factor: 3.847

3.  Heat-Mitigated Design and Lorentz Force-Based Steering of an MRI-Driven Microcatheter toward Minimally Invasive Surgery.

Authors:  Martin Francis Phelan; Mehmet Efe Tiryaki; Jelena Lazovic; Hunter Gilbert; Metin Sitti
Journal:  Adv Sci (Weinh)       Date:  2022-02-03       Impact factor: 16.806

  3 in total