Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants.

S Kahraman1, B T Bal, N V Asar, I Turkyilmaz, T F Tözüm.   

Abstract

Resonance frequency (RF) analysis is a non-invasive, objective and sensitive technique developed for implantology where it measures the stability of the implant in osteotomy site. Although many studies were performed by the previous electronic version of RF analyzer, a very limited number of studies were carried out with the new magnetic wireless version. The aim of the study was to evaluate the relation between insertion torques, primary and secondary stability of self-tapping tapered implant systems. Thirteen subjects were treated with 42 endosseous implants using two-stage surgical procedure. The maximal insertion torque values were recorded prior to RF analysis during surgery. Six months after surgery, the secondary stability values were measured by the RF analysis. The average maximal insertion torque and primary and secondary magnetic RF values were 33 +/- 11 N cm and 66 +/- 12 ISQ and 71.9 +/- 6 ISQ for 42 implants respectively. The correlation between insertion torque and RF values were indicated to be statistically significant (P < 0.01). Significantly higher maximal insertion torque, and primary and secondary magnetic RF values were achieved in mandibular sites compared with maxillary areas (P < 0.01). No significant differences were measured for all parameters when both systems were compared with each other (P > 0.05). There was a strong correlation between the insertion torque, primary and secondary magnetic RF values of self-tapping tapered endosseous implant used. Further studies are needed to understand the impact of the wireless magnetic RF analysis technique in clinics.

Mesh:

Substances:

Year:  2009        PMID: 19758410     DOI: 10.1111/j.1365-2842.2009.01990.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  13 in total

1.  Early outcome of an implant system with a resorbable adhesive calcium-phosphate coating--a prospective clinical study in partially dentate patients.

Authors:  Victor Palarie; Constantin Bicer; Karl M Lehmann; Mohammad Zahalka; Florian G Draenert; Peer W Kämmerer
Journal:  Clin Oral Investig       Date:  2011-08-06       Impact factor: 3.573

2.  Replacement of Destructive Pull-out Test with Modal Analysis in Primary Fixation Stability Assessment of Spinal Pedicle Screw.

Authors:  Mohammadjavad Einafshar; Ata Hashemi; Gerrit Harry van Lenthe
Journal:  Arch Bone Jt Surg       Date:  2022-02

3.  Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test.

Authors:  Dorjpalam Bayarchimeg; Hee Namgoong; Byung Kook Kim; Myung Duk Kim; Sungtae Kim; Tae-Il Kim; Yang Jo Seol; Yong Moo Lee; Young Ku; In-Chul Rhyu; Eun Hee Lee; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

4.  Analysis of primary stability of dental implants inserted in different substrates using the pullout test and insertion torque.

Authors:  Nathalia Ferraz Oliscovicz; Antônio Carlos Shimano; Elcio Marcantonio Junior; César Penazzo Lepri; Andréa Candido Dos Reis
Journal:  Int J Dent       Date:  2013-01-22

5.  Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis.

Authors:  Gorka Santamaría-Arrieta; Aritza Brizuela-Velasco; Felipe J Fernández-González; David Chávarri-Prado; Yelko Chento-Valiente; Eneko Solaberrieta; Markel Diéguez-Pereira; José-Antonio Vega; Jaime Yurrebaso-Asúa
Journal:  J Clin Exp Dent       Date:  2016-07-01

6.  Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles.

Authors:  Fernanda Faot; Amália Machado Bielemann; Alessandra Julie Schuster; Raissa Micaella Marcello-Machado; Altair Antoninha Del Bel Cury; Gustavo G Nascimento; Otacílio Luiz Chagas-Junior
Journal:  Biomed Res Int       Date:  2019-06-02       Impact factor: 3.411

7.  Repeatability of the resonance frequency analysis values in implants with a new technology.

Authors:  M-C Díaz-Castro; A Falcao; P López-Jarana; C Falcao; J-V Ríos-Santos; A Fernández-Palacín; M Herrero-Climent
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

8.  The evaluation of implant stability measured by resonance frequency analysis in different bone types.

Authors:  Naser Sargolzaie; Sarah Samizade; Hamidreza Arab; Habibollah Ghanbari; Leila Khodadadifard; Amin Khajavi
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2019-02-26

9.  Biomechanical Effects of a New Macrogeometry Design of Dental Implants: An In Vitro Experimental Analysis.

Authors:  Sergio Alexandre Gehrke; Leticia Pérez-Díaz; Patricia Mazón; Piedad N De Aza
Journal:  J Funct Biomater       Date:  2019-10-25

10.  Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design.

Authors:  Domenico Baldi; Teresa Lombardi; Jacopo Colombo; Gabriele Cervino; Giuseppe Perinetti; Roberto Di Lenarda; Claudio Stacchi
Journal:  Biomed Res Int       Date:  2018-05-15       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.