Literature DB >> 19755932

Measurement of total and compartmental lung volume changes in newborns by optoelectronic plethysmography.

Raffaele L Dellaca'1, Maria L Ventura, Emanuela Zannin, Miria Natile, Antonio Pedotti, Paolo Tagliabue.   

Abstract

The study of respiratory mechanics in infants requires a noninvasive accurate measurement of the lung volume changes (DeltaVL). Optoelectronic plethysmography (OEP) allows the assessment of DeltaVL through the measurement of the chest wall surface motion and it has been proved to be accurate in adults. The aim of this study was to apply OEP to newborns and to validate it by comparison to pneumotachography. Twenty term and preterm newborns (GA = 34 +/- 5 wk) in stable condition were studied during 1 to 2 min periods of quiet breathing in supine position. Airway opening flow was measured by applying a facemask connected to a pneumotachograph (PNT) and integrated to provide the DeltaVL. Chest wall volume changes were simultaneously measured by OEP. The tidal volume values measured by pneumotachography and by OEP were compared for each breath. A total of 771 breaths from all patients were considered. Bland-Altmann analysis showed a mean difference of -0.08 mL and a limit of agreement ranging from -2.98 to 2.83 mL. Linear regression analysis demonstrated good correlation between the two techniques (r = 0.95, q = 1.00 mL, m = 0.96). OEP provides accurate measurements of DeltaVL in newborns and may be useful to study respiratory mechanics and breathing patterns during spontaneous breathing and mechanical ventilation.

Entities:  

Mesh:

Year:  2010        PMID: 19755932     DOI: 10.1203/PDR.0b013e3181c0b184

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  6 in total

1.  Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study.

Authors:  Valeria Ottaviani; Chiara Veneroni; Raffaele L Dellaca'; Anna Lavizzari; Fabio Mosca; Emanuela Zannin
Journal:  IEEE J Transl Eng Health Med       Date:  2022-03-21

2.  Continuous non-invasive monitoring of tidal volumes by measurement of tidal impedance in neonatal piglets.

Authors:  Florian Kurth; Fabienne Zinnow; Alexandra Prakapenia; Sabrina Dietl; Stefan Winkler; Sascha Ifflaender; Mario Rüdiger; Wolfram Burkhardt
Journal:  PLoS One       Date:  2011-06-07       Impact factor: 3.240

3.  Spontaneous Breathing Pattern as Respiratory Functional Outcome in Children with Spinal Muscular Atrophy (SMA).

Authors:  A LoMauro; A Aliverti; C Mastella; M T Arnoldi; P Banfi; G Baranello
Journal:  PLoS One       Date:  2016-11-07       Impact factor: 3.240

4.  Quantitative Analysis by 3D Graphics of Thoraco-Abdominal Surface Shape and Breathing Motion.

Authors:  Andrea Aliverti; Davide Lacca; Antonella LoMauro
Journal:  Front Bioeng Biotechnol       Date:  2022-07-13

5.  Investigating Stroke Effects on Respiratory Parameters Using a Wearable Device: A Pilot Study on Hemiplegic Patients.

Authors:  Joshua Di Tocco; Daniela Lo Presti; Martina Zaltieri; Marco Bravi; Michelangelo Morrone; Silvia Sterzi; Emiliano Schena; Carlo Massaroni
Journal:  Sensors (Basel)       Date:  2022-09-05       Impact factor: 3.847

6.  Measurement of chest wall motion using a motion capture system with the one-pitch phase analysis method.

Authors:  Hiroyuki Tamiya; Akihisa Mitani; Hideaki Isago; Taro Ishimori; Minako Saito; Taisuke Jo; Goh Tanaka; Shintaro Yanagimoto; Takahide Nagase
Journal:  Sci Rep       Date:  2021-11-02       Impact factor: 4.379

  6 in total