Literature DB >> 19753227

Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators.

Vikas Kulshrestha1.   

Abstract

BACKGROUND: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail.
MATERIALS AND METHODS: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature.
RESULTS: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10), 14 Gustilo type 2 (n=14), and type3 (n=6) cases. 6 cases (20%) had clamp site infection, 2 cases (6.7%) had deep infection, and in 28 cases (93%) the fracture healed and consolidated well.
CONCLUSION: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection.

Entities:  

Keywords:  Open tibial fracture; intramedullary nailing; pinless fixator

Year:  2008        PMID: 19753227      PMCID: PMC2740348          DOI: 10.4103/0019-5413.43382

Source DB:  PubMed          Journal:  Indian J Orthop        ISSN: 0019-5413            Impact factor:   1.251


INTRODUCTION

Tibia is the commonest site for open fractures.1 These injuries often result in extensive damage to the soft tissue and bone. With high rates of infection and frequent injury to neurovascular structures, they have a high incidence of complications and poor treatment outcome.2 Treating these injuries requires experience and judgment.3 It remains one of the most challenging problems facing the orthopedic surgeon.4 Modern-day management of these injuries has focused on thorough debridement, immediate bony stabilization, and tissue cover to enable early mobility and restoration of optimum function.5–7 Primary internal fixation in the form of interlocked nailing is being undertaken in most of these fractures.38–10 Staged treatment with primary external fixation is preferred only for patients who either present late1112 or have multiple injuries precluding immediate intramedullary nailing. All models of external fixators suffer from one critical disadvantage: they perforate the cortex and enter the medullary canal, thus exposing the canal to pin tract infection. Pin tract infection is seen in more than 40% cases.13–17 Maurer and Gustilo18 in their study showed that exchange nailing after external fixation using pin fixator had 25% chance of deep infection, and the same was as high as 71% when nailing was done after there was an evidence of pin tract infection. Most of the studies have shown a high risk of deep infection (more than 20%) when exchange intramedullary nailing is done after external fixation with pin fixators.19–21 McGraw and Lim22 reported 44% deep infection after exchange nailing. The AO pinless external fixator does not violate the intramedullary canal, as the fixator clamps simply rest on the cortical bone without penetrating it [Figure 1]. The medullary canal remains closed, and possible inflammation is restricted to soft tissue. Thus, an early intramedullary nailing is possible.23 Pinless fixator rapidly achieves good stabilization of the fracture, while leaving open all options for subsequent treatment.14 The primary objective of this study was to asses the role of pinless fixator in primary stabilization of open tibial fractures in patients who underwent staged treatment because of delayed presentation or poor general condition. In addition, we analyzed the incidence of deep infection on conversion to intramedullary nail.
Figure 1

(a) Picture shows unicortical hold of pinless clamps. (b) Picture shows large, small, and asymmetric clamps above downwards on the left; connecting post and locking handle above downwards on right.

(a) Picture shows unicortical hold of pinless clamps. (b) Picture shows large, small, and asymmetric clamps above downwards on the left; connecting post and locking handle above downwards on right.

MATERIALS AND METHODS

We retrospectively reviewed 30 cases of open diaphyseal fractures of the tibia of varying severity that were managed at our institute from 2001 to 2003 with primary stabilization with pinless fixator. All the cases included in the study had a staged treatment (primary external fixation followed by intramedullary nailing) because of either delayed presentation or multiple associated injuries. Cases that had less than two-year follow-up were not included in the study. All the fractures were classified as per AO fracture classification24 for fracture anatomy and Gustilo and Anderson classification2526 for nature of open injury. All the fractures selected were of the diaphyseal segment. In all the cases, the pinless fixator was applied within 8 h of hospital admission. The AO pinless external fixator includes three different clamp designs [Figure 2]. For the proximal metaphyseal fixation, large clamps were used; for the midshaft, the asymmetric ones were used; and for distal fixation, the small ones were used. The fixator was applied under spinal anesthesia. Individual clamps were inserted through stab incision with the aid of locking handle. Rocking movements were used to anchor the clamp tips to the outer cortex. This was confirmed by lifting the fragment using the clamp. The rocking movement was avoided during the application of asymmetric clamp. Depending on the geometry of fracture and condition of soft tissues, each main fragment received two clamps. Due care was taken to avoid impaling musculotendinous units by the clamps. This was ensured by making small skin incisions going in till the bone before inserting the clamps. Once the clamps were in position, the fracture was reduced under vision or, if required, under image control, ensuring proper alignment of the medullary canal. This was done to facilitate closed intramedullary nailing subsequently. This was followed by the application of tubular connecting rod and tightening of all screws [Figure 3]. Attempt was made to achieve soft tissue cover by loose closure of soft tissue. However, in two cases of Gustilo type III injuries, adequate soft tissue cover could not be achieved in the first sitting.
Figure 2

Plain radiograph of fracture of distal third tibia stabilized with pinless fixator. A well-aligned medullary canal with a four-clamp pinless frame can be seen.

Figure 3

Pictures of pinless fixator used for stabilization of open fracture tibia. (a) An external fixator is in situ for an open fracture of tibia. (b) A close view of the pin site, with limb swelling almost subsided and the pressure on skin around the clamp relieved. (c) Postoperative radiograph shows well aligned fracture stabilized with four-clamp pinless fixator.

Plain radiograph of fracture of distal third tibia stabilized with pinless fixator. A well-aligned medullary canal with a four-clamp pinless frame can be seen. Pictures of pinless fixator used for stabilization of open fracture tibia. (a) An external fixator is in situ for an open fracture of tibia. (b) A close view of the pin site, with limb swelling almost subsided and the pressure on skin around the clamp relieved. (c) Postoperative radiograph shows well aligned fracture stabilized with four-clamp pinless fixator. In AO type A and B fracture pattern, the pinless fixator ensured reasonable stability permitting early mobilization in the postoperative period. However, in three cases of AO type C fracture pattern, additional below-knee plaster slab was applied to augment stability while transporting the patient after the surgery. In the ward, the slab was removed and the limb was shifted to Bohler Braun splint. In these cases, we permitted only gradual ankle movements in the immediate postoperative period. In all cases, intravenous antibiotics were used. In cases with Gustilo type I and II injuries, a cephalosporin was used along with aminoglycoside for 72 h. In all Gustilo type III injuries, the same intravenous antibiotics were given for 5 days along with intravenous metronidazole for the first 3 days. This antibiotic protocol was evolved over a period of time at our institute in consultation with the infection control committee, after a review of available literature27–30 and study of local antibiotic sensitivity patterns. Adequate period of limb elevation was ensured to combat local swelling. Once swelling subsided, the pressure of clamps over the nearby skin was also relieved, and pin site care was easy [Figure 3b]. Further debridement was done in the operating room at 2- to 5-day intervals as needed, followed by changes of the dressing in the ward as the condition of the wound improved. Meticulous soft tissue care was given with the help of plastic surgeon using biological dressings. Pin site care was given in the form of removal of crust, gentle massage of soft tissue around the pin site, and simple dressing with saline. Non weight bearing ambulation was allowed after stabilization of soft tissue varying from 3 to 7 days in all but three cases of AO type C fracture. Once there were no signs of local wound infection (no swelling, erythema, or discharge), patients were allowed for definitive internal fixation with intramedullary nail. Because of cost constraints in cases of simple AO type A fractures, we used a modified K nail. The conventional K nail was given Herzog bend proximally and distal bevel to negotiate the medullary canal easily. However, since last 4 years, we use only interlock nails. This method was used in seven cases for internal fixation of the fracture [Figure 4]. In all other cases AO type B and C fractures, unreamed interlocking titanium nail (Mathys AG, Bettlach, Switzerland) was used.
Figure 4

Shows image of the modified K nail used to fix a simple oblique fracture of tibia. The modification in the K nail with anterior bend given in the proximal third of the K nail to compensate for the medullary canal and the oblique leading edge can be seen.

Shows image of the modified K nail used to fix a simple oblique fracture of tibia. The modification in the K nail with anterior bend given in the proximal third of the K nail to compensate for the medullary canal and the oblique leading edge can be seen. A fracture table was used for insertion of unreamed tibial nail (to facilitated distal free hand locking); however, modified K nailing was done on normal table. On the fracture table, the hip was flexed 45°, the knee was flexed 90°, and the thigh was supported with a well-padded crossbar. Traction was not applied, and the foot was just strapped to the foot plate to maintain position [Figure 5A(a)]. The limb was then prepared and draped. A 5-cm long longitudinal incision was made medial to the patellar tendon, and the tendon was retracted laterally. A curved awl was used to make the entrance portal at the midline of the tibia at the level of the fibular head. A nail of proper length and diameter was selected as per template under fluoroscopy and was driven into the medullary canal without reaming. For unreamed tibial nail, the proximal locking jig was attached to the nail before insertion. Care was taken to ensure that the fracture was properly aligned as the nail entered the medullary canal of the distal fragment [Figure 5A(b)]. The fixator was removed after the nail was in situ; the distal locking was performed first to enable compression/distraction at the fracture site if required. The nail was statically locked using double proximal and distal locking bolts [Figure 5A(c)].
Figure 5A

Pictures of closed intramedullary nailing. (a) Shows fractured limb strapped to the foot plate of fracture table being prepared for closed exchange nailing under image intensifier control, with fixator in situ. (b) Image intensifier picture shows unreamed tibial nail being inserted by closed technique while pinless fixator maintains reduction.

Pictures of closed intramedullary nailing. (a) Shows fractured limb strapped to the foot plate of fracture table being prepared for closed exchange nailing under image intensifier control, with fixator in situ. (b) Image intensifier picture shows unreamed tibial nail being inserted by closed technique while pinless fixator maintains reduction. Following definitive internal fixation, soft tissue condition was evaluated. In most cases, no additional soft tissue procedure was required, as the wound had almost dried up with decrease in limb swelling. However, in six patients, split skin grafting was required, and in two patients of Gustilo 3B fracture, local fasciocutaneous rotation flap cover was required to achieve wound cover. In all cases with interlocked nail in situ, partial weight-bearing ambulation was started as tolerated by the patient in immediate postoperative period. In cases with modified K nail in situ, partial weight bearing was started 2 weeks postoperatively after the removal of sutures and application of below knee patellar tendon bearing cast. All cases were closely followed in the postoperative period for evidence of superficial or deep infection at the fracture site including pin-site infection. Cases with local pain, swelling, erythema, and serous discharge (culture positive for pathogen) from the fracture site were labeled as superficial infection and were managed with elevation, drainage, and additional course of antibiotics as dictated by culture sensitivity. Patients were also monitored for evidence of deep infection in the form of wound abscess and systemic features of infection including radiological evidence of periostitis or osteomyelitis. Pin-site infection was considered to be present when there was culture-positive purulent discharge from one or more pin sites when the fixator was removed. All the cases were followed up for 6 months to 2 years for union and other complications like secondary osteomyelitis and nonunion. The subjective and objective criteria used for establishing union were absence of pain on full weight bearing, lack of swelling, tenderness, or abnormal mobility at the fracture site with radiographic evidence of bridging callus in various phases of consolidation. The injured limb was labeled free of infection in the absence of pain, swelling, or discharge from the fracture site or any of the clamp sites along with the absence of any radiological evidence of osteomyelitis, like sclerosis, osteolysis, and implant loosening.

RESULTS

The mean age of the patients was 34.9 years (ranged 21 to 60 years) [Table 1]. Most of the fractures (n=16) were wedge type with varying levels of fibular fracture (AO type 42B). Of the remaining cases, eight fractures were simple AO type 42A fractures, and six had complex AO type 42C fracture pattern. On debridement, 14 patients had Gustilo type II injury, 10 patients had Gustilo type I, and 6 patients had Gustilo type III injury and complex fracture anatomy. Average delay in debridement and application of external fixator was 28.4 h (range, 4–72 h) from the time of injury. The delay was due to late presentation, as many cases had to be moved from remote locations. Average delay in intramedullary nailing was 7.9 days. Most of the type 1 and type 2 injuries were taken up within 3–10 days for nailing, and type 3 injuries were taken up 12–14 days after injury. In eight cases (six Gustilo I and two Gustilo II), modified K nailing was done, and in the rest, unreamed interlocked titanium nail (UTN) was used. Few complications which occurred have been listed in Table 2.
Table 1

Results of thirty cases of open fracture of the tibia managed with primary stabilization with external fixator

S no.AgeAO type of fractureGustilo typeDelay in external fixation (h)Delay in nailing (days)Type of nailingWound coverSecondary procedureUnion (weeks)Complications
12142-A3.2GI83K NailNilDynamization16Nil
24242-A2.2GII65K NailNilCurettage24Nil
33642-B2.2GII247UTN*SSGNil26Nil
43542-B2.3GI326UTNNilDynamization22Nil
55142-B2.3GII3610UTNNilNil22Nil
63542-A2.2GI485K NailNilNil18Nil
73342-B2.3GIII A5612UTNSSGCurettage38Nil
83942-B3.3GI607UTNNilDynamization20Nil
92242-B3.2GII2412UTNNilNil22Nil
102442-C1.2GIIIA814UTNSSGDynamization40Nil
112942-C2.2GII610UTNNilCurettage36Nil
123042-A2.2GI105K NailNilNil20Nil
133142-B2.3GII245UTNNilDynamization22Nil
146042-C2.2GIII B7212UTNFlapNil-Nonunion
153242-B2.2GII125UTNNilNil30Nil
162242-A3.2GI104K NailNilDynamization18Nil
174342-A2.2GII44K NailNilCurettage22Nil
183542-B2.2GII248UTNSSGNil28Nil
193642-B2.3GI305UTNNilDynamization20Nil
205042-B2.3GII3811UTNNilNil24Nil
213642-A2.2GI464K NailNilNil16Nil
223242-B2.3GIII A5813UTNSSGCurettage40Nil
234142-B3.3GI586UTNNilDynamization18Nil
242142-B3.2GII2213UTNNilNil24Nil
252842-C1.2GIII A813UTNSSGDynamization38Nil
262842-C2.2GII811UTNNilCurettage38Nil
273142-A2.2GI124K NailNilNil18Nil
283042-B2.3GII226UTNNilDynamization24Nil
296142-C2.2GIII B7011UTNFlapNil-Nonunion
303142-B2.2GII126UTNNilNil28Nil

Unreamed tibial nail.

Table 2

Complications/difficulties encountered in management

S no.ResultsIncidence(%)
1Delayed union requiring dynamization10 (33)
2Superficial soft tissue infection due to clamp06 (20)
3Deep infection and infected nonunion02* (07)
4Unstable frame prevented early mobilization03 (10)
5Secondary cover required08 (27)

Both were Gustilo III B injuries with > 10 days delay in exchange nailing.

All these fractures were AO type 42C.

Results of thirty cases of open fracture of the tibia managed with primary stabilization with external fixator Unreamed tibial nail. Complications/difficulties encountered in management Both were Gustilo III B injuries with > 10 days delay in exchange nailing. All these fractures were AO type 42C. In six patients (20%), there was a discharge from the clamp site, which was cured by curettage of the outer cortex and oral antibiotics for a short period. This did not affect the result of exchange nailing. In none of these cases, there was an evidence of deep infection or implant loosening. Two patients (6%) with Gustilo IIIB injury developed deep infection around the intramedullary nail 3–4 weeks after nailing. The fracture developed into an infected nonunion, requiring removal of the implant. Both the patients were later treated with ring fixator. Both these cases reported close to 3 days after the injury, as against most of the other cases, which reported within a day of the injury (average 28.4 h). In both these cases, there was more than 10 days of delay in the exchange nailing, and wound cover was achieved with split skin grafting. In most of the cases (27 out of 30), pinless fixator provided reasonable stability to the fracture, and the patient was able to perform almost full range of knee and ankle movements. However, weight bearing ambulation was not permitted. In three cases (10%), pinless fixator could not ensure reasonable stability, and all these cases had complex fracture anatomy (AO type 42C). In these cases, full range of knee and ankle movements were not permitted, and additional protection was provided in the form of immobilization over Bohler Braun splint. Ambulation was not permitted in all these cases. Only during the first 24–48 h, while there was significant swelling of the limb, the pin-site care was difficult because there was some pressure of the clamp claws over the surrounding skin. Once the limb swelling subsided, pressure over the surrounding skin was relieved. Subsequently, the pin site care was same as that for any pin fixator. There were no cases of skin necrosis due to clamps. In all the cases, soft tissue healing was excellent in the postoperative period. Once the initial limb swelling subsided, most of the wounds (73%; 22 out of 30) shrunk in size and healed rapidly without any sign of infection. To achieve complete soft tissue cover, split skin grafting was required in six cases (20%), and local fasciocutaneous rotation flap was required in two cases of Gustilo IIIB fracture (7%). However, these procedures were done after exchange nailing. In no case, there was any evidence of distal neurological deficit. In 10 cases, during the 12-week postsurgery follow-up, dynamization of the fracture site was required, as there was clinicoradiological features of delayed union in the form of mild pain at the fracture site on weight-bearing and poor bridging callus. Out of the 10 cases, in eight cases the fracture had been fixed with statically locked unreamed nail which were dynamized by removing the distal static locking bolts when the fracture was close to proximal third and the proximal ones when it was close to distal third. In two cases, where modified K nailing was done, dynamization of the fracture was achieved by fibulectomy. In all these cases, the fracture united at 5–6 months from injury. Average time to union was 25.4 weeks [Figure 5B]. In Gustilo type I fractures, the average time to union was 19 weeks, whereas for Gustilo types II and III, it was 26 and 39 weeks, respectively. There were two cases of frank nonunion (7%), both followed by infection of the fracture site and loosening of the implant. There were no cases of malunion or hardware failure.
Figure 5B

(a) Postoperative radiograph AP and lateral of the fracture showing good reduction and fixation with unreamed tibial nail (UTN) and double distal locking in situ. (b) Radiograph lateral and AP after 12 weeks of surgery, showing ongoing bridging of fracture site and consolidation. (c) Radiograph lateral and AP after 24 weeks of surgery, in which healing is almost complete.

(a) Postoperative radiograph AP and lateral of the fracture showing good reduction and fixation with unreamed tibial nail (UTN) and double distal locking in situ. (b) Radiograph lateral and AP after 12 weeks of surgery, showing ongoing bridging of fracture site and consolidation. (c) Radiograph lateral and AP after 24 weeks of surgery, in which healing is almost complete.

DISCUSSION

Primary interlocking nail can safely and reproducibly stabilize most low-energy and selected high-energy open fractures of the leg.3 However, primary nailing may not be feasible in cases of delayed presentation and polytrauma. These cases require staged reconstructive protocol using external fixation as the primary method of bony stabilization. Review of the available literature shows that use of conventional pin fixators is associated with a high risk of pin tract infection. Hence, exchange intramedullary nailing within 10–12 days is recommended. If exchange nailing is delayed (more than 3 weeks), the rate of infection rises remarkably (20–45%). If there is established pin tract infection, it may even be as high as 71%.13151831–33 The AO pinless fixator for the tibia has been designed as a stable, temporary, minimally invasive fixator for severe tibial fractures, ensuring safer conversion to an intramedullary nail.30 Early conversion to a more stable implant with significantly reduced incidence of infection is one of the primary goals of this system.31 Review of literature did not reveal any study that conclusively established a decrease in the rate of infection following exchange nailing after primary stabilization with pinless fixators. We received patients from remote locations with multiple injuries. At the time of initial debridement (average delay 28.4 h), primary internal fixation was not possible because of the condition of the wound. There were few cases in which primary internal fixation was ruled out because of associated injuries. With staged treatment using pinless fixator for primary stabilization of the fracture, the overall rate of deep infection was 6%. This result is comparable to that of primary unreamed nailing of these fractures wherein various recent studies1322233234 have revealed infection rates of 5–12% for management of Gustilo types II and III fractures. Pinless fixator is of help during exchange nailing, as it can be used to maintain fracture reduction while exchange intramedullary nailing is performed under image intensifier. This avoids unnecessary manipulation of the limb to achieve reduction, thus preventing further damage to the soft tissue143135–39. Few problems of pinless fixator that have been brought out by some studies are poor stability provided by pinless frame, skin necrosis and sloughing around the pin site, impalement of musculotendinous units including damage to peroneal nerve, and difficulty in performing secondary procedures for skin cover. Winkler et al. observed that the arm of the pinless clamp does cause increased pressure on the skin and surrounding soft tissue, which may lead to skin necrosis.38 In this study, we saw that once the swelling subsided, there was no pressure on the surrounding soft tissues. During the insertion of clamps, a wider skin incision (instead to stab incisions) was made to avoid pressure on the surrounding tissue. Thomas found that the pinless external fixator endangered important anatomical structures and that safe zones could not always be defined.23 Plastic surgical approaches were made more difficult by the pinless fixator, which imposed limitations on local flap design and endangered the arterial perforators that supply them. We did not encounter any difficulty in safe placement of the clamps over the subcutaneous medial surface of the tibia. However, necessary care was taken not to impale the structures on the lateral side by giving larger skin incision and ensuring safe passage of the clamp till the bony surface. Regular wound care and occasional debridement was convenient even with the fixator applied. Procedures like flap cover and split skin grafting were done after exchange nailing. With the fixator in situ, it was not possible to do a flap cover; however, a split skin cover could be achieved without difficulty. The pinless fixator provides enough stability to maintain reduction and allow good range of movements of the adjoining joints.11 The pinless fixator is stable enough for temporary fracture fixation of the tibia in a four-clamp, 1-bar construction. Proper application technique (“grab test”, rocking movements) is a prerequisite for stability. Weight-bearing should be avoided and needs a compliant patient.34 Reimeger in his study showed that the pinless configurations with small clamps and 1-bar pressure showed stiffness values (as a percentage of the corresponding AO-tubular fixator): 42/36% (steel/titanium clamp) axial stiffness, 61/43% bending stiffness perpendicular to the reference plane, 78/79% bending stiffness parallel to the reference plane, and 90/95% torsional stiffness.19 When compared with AO pin fixators, pinless frame is purely a temporary method of stabilizing open tibial shaft fractures, needing early revision to definitive internal fixation. This obviates the need for a very rigid frame that permits weight-bearing and can be kept for a prolonged period of time. There are few limitations of the study. First, there were no blind observers. Second, although AO classification of fracture pattern is quiet accurate with negligible intraobserver variation, the same cannot be said for Gustilo classification of open injury. Finally, being a retrospective study, proper randomization and comparison with a control cohort who underwent primary stabilization with pin fixator was not possible; hence, the available literature was used to compare the results of this study. The major strength of the study is a well-defined uniform protocol followed for all cases, operated and managed at the same institute by the same surgeon. This excludes many other variables that change from institute to institute and from surgeon to surgeon. The additional benefits of the system as highlighted in this study have evolved with the increasing use of this system. The advantages of pinless fixation are its simplicity of application, its nonpenetrating clamp, and its use as a reduction aid for conversion to intramedullary nail. This study shows that the use of pinless external fixator, when indicated (delayed presentation/polytrauma situation) for primary stabilization of open tibial shaft fracture, facilitates further management and decreases the rate of infection after intramedullary nailing as seen with the use of pin fixators. However, it cannot be used for definitive fixation of the fracture. It is a valuable addition to the existing AO tubular system.
  37 in total

1.  The development of the Pinless external fixator: from the idea to the implant.

Authors:  R Frigg
Journal:  Injury       Date:  1992       Impact factor: 2.586

2.  Pinless external fixation. Indications and preliminary results in tibial shaft fractures.

Authors:  M Schütz; N Südkamp; R Frigg; R Hoffman; U Stöckle; N Haas
Journal:  Clin Orthop Relat Res       Date:  1998-02       Impact factor: 4.176

3.  External fixation and secondary intramedullary nailing of open tibial fractures. A randomised, prospective trial.

Authors:  P Antich-Adrover; D Martí-Garin; J Murias-Alvarez; C Puente-Alonso
Journal:  J Bone Joint Surg Br       Date:  1997-05

4.  Current concepts in the management of open fractures.

Authors:  R B Gustilo
Journal:  Instr Course Lect       Date:  1987

Review 5.  Classification of type III (severe) open fractures relative to treatment and results.

Authors:  R B Gustilo; R P Gruninger; T Davis
Journal:  Orthopedics       Date:  1987-12       Impact factor: 1.390

6.  Complicated open fractures of the distal tibia treated by secondary interlocking nailing.

Authors:  C C Wu; C H Shih
Journal:  J Trauma       Date:  1993-06

7.  Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses.

Authors:  R B Gustilo; J T Anderson
Journal:  J Bone Joint Surg Am       Date:  1976-06       Impact factor: 5.284

8.  Objective criteria accurately predict amputation following lower extremity trauma.

Authors:  K Johansen; M Daines; T Howey; D Helfet; S T Hansen
Journal:  J Trauma       Date:  1990-05

9.  Experience with the pinless fixator in the treatment of fractures of the lower leg.

Authors:  H Winkler; P Hochstein; A Wentzensen
Journal:  Injury       Date:  1994       Impact factor: 2.586

10.  Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation.

Authors:  D J Maurer; R L Merkow; R B Gustilo
Journal:  J Bone Joint Surg Am       Date:  1989-07       Impact factor: 5.284

View more
  2 in total

1.  Fast pinless external fixation for open tibial fractures: preliminary report of a prospective study.

Authors:  Zheyuan Huang; Bowen Wang; Fengrong Chen; Jianming Huang; Guojian Jian; Hao Gong; Tianrui Xu; Ruisong Chen; Xiaolin Chen; Zhiyang Ye; Jun Wang; Desheng Xie; Haoyuan Liu
Journal:  Int J Clin Exp Med       Date:  2015-11-15

2.  Sequential management of tibial fractures using a temporary unicortical external fixator.

Authors:  Anne-Pauline Russo; Alexandre Caubere; Ammar Ghabi; Antoine Grosset; Philippe Mangin; Sylvain Rigal; Laurent Mathieu
Journal:  SICOT J       Date:  2018-09-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.