Literature DB >> 19750453

Is bacteriologic surveillance in endoscope reprocessing stringent enough?

J Kovaleva1, N E L Meessen, F T M Peters, M H Been, J P Arends, R P Borgers, J E Degener.   

Abstract

Endoscopes, including duodenoscopes, are medical devices that are frequently associated with outbreaks of nosocomial infections. We investigated an outbreak of multidrug-resistant PSEUDOMONAS AERUGINOSA sepsis affecting three patients after endoscopic retrograde cholangiopancreaticography (ERCP). Epidemiologic investigation supplemented by molecular typing revealed that one ERCP scope was the source of infection with P. AERUGINOSA. No contamination with this microorganism was found after screening of washer-disinfectors, connecting tubes, and environmental surfaces in the endoscopy center. PSEUDOMONAS isolates from blood and endoscope channels before gas sterilization with ethylene oxide (ETO) were characterized by molecular typing as "linked isolates". Though the current surveillance system did not prevent the infections in three patients, our microbiological surveillance protocol with routine culturing of endoscopes was helpful in detecting the source of contamination and probably avoided numerous cross-contaminations in other patients who underwent ERCP procedures with endoscopes. Georg Thieme Verlag KG Stuttgart. New York.

Entities:  

Mesh:

Year:  2009        PMID: 19750453     DOI: 10.1055/s-0029-1215086

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  18 in total

1.  Assessment on experimental bacterial biofilms and in clinical practice of the efficacy of sampling solutions for microbiological testing of endoscopes.

Authors:  C Aumeran; E Thibert; F A Chapelle; C Hennequin; O Lesens; O Traoré
Journal:  J Clin Microbiol       Date:  2011-12-14       Impact factor: 5.948

Review 2.  Duodenoscope-Associated Infections: Update on an Emerging Problem.

Authors:  M Rubayat Rahman; Abhilash Perisetti; Roxana Coman; Pardeep Bansal; Rajiv Chhabra; Hemant Goyal
Journal:  Dig Dis Sci       Date:  2018-12-19       Impact factor: 3.199

Review 3.  Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

Authors:  Günter Kampf; Patricia M Fliss; Heike Martiny
Journal:  World J Gastrointest Endosc       Date:  2014-09-16

Review 4.  Hygiene: The Looming Achilles Heel in Endoscopy.

Authors:  Michael Jung; Ulrike Beilenhoff
Journal:  Visc Med       Date:  2016-02-10

Review 5.  Duodenoscope-associated infections: a review.

Authors:  Gheorghe G Balan; Catalin Victor Sfarti; Stefan Andrei Chiriac; Carol Stanciu; Anca Trifan
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2019-09-03       Impact factor: 3.267

Review 6.  Gastrointestinal Endoscopy-Associated Infections: Update on an Emerging Issue.

Authors:  Anasua Deb; Abhilash Perisetti; Hemant Goyal; Mark M Aloysius; Sonali Sachdeva; Dushyant Dahiya; Neil Sharma; Nirav Thosani
Journal:  Dig Dis Sci       Date:  2022-03-09       Impact factor: 3.487

Review 7.  Methylobacterium and its role in health care-associated infection.

Authors:  Julia Kovaleva; John E Degener; Henny C van der Mei
Journal:  J Clin Microbiol       Date:  2014-01-15       Impact factor: 5.948

Review 8.  Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy.

Authors:  Julia Kovaleva; Frans T M Peters; Henny C van der Mei; John E Degener
Journal:  Clin Microbiol Rev       Date:  2013-04       Impact factor: 26.132

9.  Early Assessment of the Likely Cost Effectiveness of Single-Use Flexible Video Bronchoscopes.

Authors:  Christoffer Lilja Terjesen; Julia Kovaleva; Lars Ehlers
Journal:  Pharmacoecon Open       Date:  2017-06

10.  High prevalence rate of digestive tract bacteria in duodenoscopes: a nationwide study.

Authors:  Marco J Bruno; Margreet C Vos; Arjan W Rauwers; Anne F Voor In 't Holt; Jolanda G Buijs; Woutrinus de Groot; Bettina E Hansen
Journal:  Gut       Date:  2018-04-10       Impact factor: 23.059

View more