The efficacy of chlorination and filtration in the control and eradication of Legionella from dental chair water systems.

C L Pankhurst1, J N Philpott-Howard, J H Hewitt, M W Casewell.   

Abstract

The apparent failure of hyperchlorination and continuous dosing with chlorine to eliminate legionellae from a dental teaching hospital water supply prompted a prospective study to evaluate charcoal filters as a means of decontamination. Legionella pneumophila serogroup 10 and L. bozemanii serogroup 2 were isolated from dental units yielding 10(1)-10(3) colony forming units (cfu) ml-1 with total bacterial counts in the range 10(2)-greater than 10(4) cfu ml-1. After chair-side installation of charcoal filters bacterial contamination of the dental unit water was prevented and legionellae were initially not detected, but after 7 days the total count returned to pre-filtration levels of greater than 10(4) cfu ml-1; L. pneumophila serogroup 10 was eliminated but L. bozemanii serogroup 2 persisted. These results suggest that neither chlorination nor charcoal filtration deal adequately with the potential hazard of Legionella spp. in dental water.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 1974912     DOI: 10.1016/0195-6701(90)90044-o

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  7 in total

1.  Microbial biofilm formation and contamination of dental-unit water systems in general dental practice.

Authors:  J T Walker; D J Bradshaw; A M Bennett; M R Fulford; M V Martin; P D Marsh
Journal:  Appl Environ Microbiol       Date:  2000-08       Impact factor: 4.792

Review 2.  Biofilms: survival mechanisms of clinically relevant microorganisms.

Authors:  Rodney M Donlan; J William Costerton
Journal:  Clin Microbiol Rev       Date:  2002-04       Impact factor: 26.132

3.  Effect of biocides on biofilm bacteria from dental unit water lines.

Authors:  I Liaqat; A N Sabri
Journal:  Curr Microbiol       Date:  2008-03-06       Impact factor: 2.188

4.  Legionella contamination of dental-unit waters.

Authors:  R M Atlas; J F Williams; M K Huntington
Journal:  Appl Environ Microbiol       Date:  1995-04       Impact factor: 4.792

5.  Evaluation of gram negative bacterial contamination in dental unit water supplies in a university clinic in tabriz, iran.

Authors:  Firoz Pouralibaba; Esrafil Balaei; Atabak Kashefimehr
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-09-05

6.  Effects of hydrogen peroxide on dental unit biofilms and treatment water contamination.

Authors:  Shih-Ming Lin; Kathy K H Svoboda; Anthony Giletto; Jeff Seibert; Raghunath Puttaiah
Journal:  Eur J Dent       Date:  2011-01

7.  Disinfection of dental unit water line using aloe vera: in vitro study.

Authors:  Sonia Pareek; Anup Nagaraj; Prateek Sharma; Mansi Atri; Satinder Walia; Shravani Naidu; Asif Yousuf
Journal:  Int J Dent       Date:  2013-09-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.