Literature DB >> 19748852

Reliability of limb alignment measurement for high tibial osteotomy with a navigation system.

J Lützner1, A F Gross, K P Günther, S Kirschner.   

Abstract

OBJECTIVE: High tibial osteotomy (HTO) is one treatment option for young and active patients with unicompartmental osteoarthritis. The success of this procedure substantially depends on the degree of correction of the mechanical axis. Computer-assisted navigation systems are believed to improve the precision of axis correction through intraoperative real-time monitoring. This study investigates the accuracy of limb alignment measurements with a navigation system on a cadaver specimen.
MATERIALS AND METHODS: The measurements were performed on a well-preserved cadaver specimen with a mechanical leg axis of 4 degrees varus. Data was collected during the HTO workflow. Repeated serial measurements were undertaken by four different surgeons. After these measurements, different landmarks were deliberately set at the wrong place to examine the influence of mistakes during registration.
RESULTS: There was a high intra- and interobserver reliability with a mean mechanical leg axis of 3.9 degrees +/- 0.7 degrees and a mean error of 0.6 degrees. The grossly incorrect placement of landmarks for knee and ankle center resulted in an incorrect mechanical leg axis of 1 degrees valgus up to 10 degrees varus.
CONCLUSION: The computer-assisted navigation system provided precise information about the mechanical leg axis, irrespective of the observer's experience.

Entities:  

Mesh:

Year:  2009        PMID: 19748852      PMCID: PMC3352228          DOI: 10.1186/2047-783x-14-10-447

Source DB:  PubMed          Journal:  Eur J Med Res        ISSN: 0949-2321            Impact factor:   2.175


  23 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note.

Authors:  C Krettek; T Miclau; O Grün; P Schandelmaier; H Tscherne
Journal:  Injury       Date:  1998       Impact factor: 2.586

3.  Tibial osteotomy for osteoarthritis of the knee.

Authors:  J P JACKSON; W WAUGH
Journal:  J Bone Joint Surg Br       Date:  1961-11

4.  [Current status of valgus angle, tibial head closing wedge osteotomy in media gonarthrosis].

Authors:  M Bonnin; P Chambat
Journal:  Orthopade       Date:  2004-02       Impact factor: 1.087

5.  A radiological method for producing precise limb alignment.

Authors:  M Saleh; P Harriman; D J Edwards
Journal:  J Bone Joint Surg Br       Date:  1991-05

6.  Proximal tibial osteotomy. Factors that influence the duration of satisfactory function.

Authors:  L S Matthews; S A Goldstein; T A Malvitz; B P Katz; H Kaufer
Journal:  Clin Orthop Relat Res       Date:  1988-04       Impact factor: 4.176

7.  Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study.

Authors:  P Hernigou; D Medevielle; J Debeyre; D Goutallier
Journal:  J Bone Joint Surg Am       Date:  1987-03       Impact factor: 5.284

8.  Computer aided high tibial open wedge osteotomy.

Authors:  Peter Keppler; Florian Gebhard; Paul A Grützner; Gongli Wang; Guoyan Zheng; Tobias Hüfner; Stefan Hankemeier; Lutz-Peter Nolte
Journal:  Injury       Date:  2004-06       Impact factor: 2.586

9.  Proximal tibial osteotomy. A critical long-term study of eighty-seven cases.

Authors:  M B Coventry; D M Ilstrup; S L Wallrichs
Journal:  J Bone Joint Surg Am       Date:  1993-02       Impact factor: 5.284

10.  A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee.

Authors:  K A Krackow; C L Pepe; E J Galloway
Journal:  Orthopedics       Date:  1990-08       Impact factor: 1.390

View more
  12 in total

1.  Precision of navigated and conventional open-wedge high tibial osteotomy in a cadaver study.

Authors:  J Lützner; A F Gross; K P Günther; S Kirschner
Journal:  Eur J Med Res       Date:  2010-03-30       Impact factor: 2.175

2.  Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique.

Authors:  Kilian Reising; Peter C Strohm; Oliver Hauschild; Hagen Schmal; Mohmed Khattab; Norbert P Südkamp; Philipp Niemeyer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-04       Impact factor: 4.342

3.  Agreement between radiological and computer navigation measurement of lower limb alignment.

Authors:  Julian Dexel; Stephan Kirschner; Klaus-Peter Günther; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-06       Impact factor: 4.342

4.  Preoperative surgical planning versus navigation system in valgus tibial osteotomy: a cross-sectional study.

Authors:  Cristiano Hossri Ribeiro; Nilson Roberto Severino; Patricia Maria de Moraes Barros Fucs
Journal:  Int Orthop       Date:  2013-06-18       Impact factor: 3.075

5.  Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy.

Authors:  JianHui Shi; Wei Lv; Yan Wang; Ben Ma; Wei Cui; ZhenZhong Liu; KeCheng Han
Journal:  Int Orthop       Date:  2018-06-27       Impact factor: 3.075

6.  Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method.

Authors:  Y Akamatsu; N Mitsugi; Y Mochida; N Taki; H Kobayashi; R Takeuchi; T Saito
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-29       Impact factor: 4.342

7.  More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy.

Authors:  Hee-June Kim; Jaeyeong Park; Ji-Yeon Shin; Il-Hyung Park; Kyeong-Hyeon Park; Hee-Soo Kyung
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-30       Impact factor: 4.342

8.  Navigation versus conventional high tibial osteotomy: systematic review.

Authors:  Khaled Hasan; Qusai Abdel Rahman; Paul Zalzal
Journal:  Springerplus       Date:  2015-06-17

9.  Are three-dimensional patient-specific cutting guides for open wedge high tibial osteotomy accurate? An in vitro study.

Authors:  Mathias Donnez; Matthieu Ollivier; Maxime Munier; Philippe Berton; Jean-Pierre Podgorski; Patrick Chabrand; Sébastien Parratte
Journal:  J Orthop Surg Res       Date:  2018-07-09       Impact factor: 2.359

10.  Comparison of Mechanical Axis and Dynamic Range Assessed with Weight Bearing Radiographs and Navigation System in Closed Wedge High Tibial Osteotomy.

Authors:  Dae Kyung Bae; Jong Whan Lee; Seong Jin Cho; Sang Jun Song
Journal:  Knee Surg Relat Res       Date:  2017-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.