Literature DB >> 19748420

Evaluation of the Copan ESwab transport system for the detection of methicillin-resistant Staphylococcus aureus: a laboratory and clinical study.

Annick Smismans1, Jan Verhaegen, Annette Schuermans, Johan Frans.   

Abstract

Methicillin-resistant Staphylococcus aureus (MRSA) has emerged as an important pathogen. Successful detection starts with the selection of an appropriate specimen collection device. The Copan ESwab, a new swab, was compared with a commonly used Copan Venturi swab for the recovery of MRSA. In vitro assessment was performed according to the Clinical and Laboratory Standards Institute (CLSI) M40-A protocol. For the clinical evaluation, 24 patients with known MRSA carriage were included. The ESwab fulfilled the CLSI acceptance criteria for MRSA viability. In the clinical study, both swabs performed equally in qualitative terms of positive and negative. However, the in vitro and in vivo evaluation revealed at least 3.6-fold higher recovery of viable MRSA with the ESwab as compared with the Venturi swab. In conclusion, the ESwab may contribute to improve the quality of a MRSA screening protocol.

Entities:  

Mesh:

Year:  2009        PMID: 19748420     DOI: 10.1016/j.diagmicrobio.2009.06.015

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  18 in total

1.  Assessment of Test Performance and Potential for Environmental Contamination Associated with a Point-of-Care Molecular Assay for Group A Streptococcus in an End User Setting.

Authors:  Leslie J Donato; Nikki K Myhre; Martha A Murray; Margaret R McDonah; Jane F Myers; Julie A Maxson; Alicia M Meek; Mark J Espy; Joseph W Furst; Brad S Karon; Matthew J Binnicker
Journal:  J Clin Microbiol       Date:  2019-01-30       Impact factor: 5.948

2.  Better detection of Staphylococcus aureus nasal carriage by use of nylon flocked swabs.

Authors:  Paul Verhoeven; Florence Grattard; Anne Carricajo; Bruno Pozzetto; Philippe Berthelot
Journal:  J Clin Microbiol       Date:  2010-09-15       Impact factor: 5.948

3.  Laboratory evaluation of the ESwab transport system for the recovery of carbapenem-resistant Acinetobacter baumannii.

Authors:  J Moran-Gilad; D Schwartz; S Navon-Venezia; Y Carmeli
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-11-09       Impact factor: 3.267

4.  Dutch guideline on the laboratory detection of methicillin-resistant Staphylococcus aureus.

Authors:  M F Q Kluytmans-van den Bergh; M C Vos; B M W Diederen; C M J E Vandenbroucke-Grauls; A Voss; J A J W Kluytmans
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-07-27       Impact factor: 3.267

5.  Detection of Group A Streptococcus in Pharyngeal Swab Specimens by Use of the AmpliVue GAS Isothermal Helicase-Dependent Amplification Assay.

Authors:  Matthew L Faron; Nathan A Ledeboer; Paul Granato; Judy A Daly; Kristina Pierce; Preeti Pancholi; Timothy S Uphoff; Blake W Buchan
Journal:  J Clin Microbiol       Date:  2015-05-13       Impact factor: 5.948

6.  MRSA screening by the Xpert MRSA PCR assay: pooling samples of the nose, throat, and groin increases the sensitivity of detection without increasing the laboratory costs.

Authors:  D S Blanc; I Nahimana; G Zanetti; G Greub
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-11-10       Impact factor: 3.267

7.  Clinical evaluation of the walk-away specimen processor and ESwab for recovery of Streptococcus agalactiae isolates in prenatal screening specimens.

Authors:  Blake W Buchan; Wendy J Olson; Tami-Lea A Mackey; Nathan A Ledeboer
Journal:  J Clin Microbiol       Date:  2014-03-12       Impact factor: 5.948

8.  Different study methods.

Authors:  Wolfgang R Heizmann
Journal:  Dtsch Arztebl Int       Date:  2014-09-12       Impact factor: 5.594

Review 9.  Emerging technologies for the clinical microbiology laboratory.

Authors:  Blake W Buchan; Nathan A Ledeboer
Journal:  Clin Microbiol Rev       Date:  2014-10       Impact factor: 26.132

10.  Comparison of ESwab with traditional swabs for detection of methicillin-resistant Staphylococcus aureus using two different walk-away commercial real-time PCR methods.

Authors:  Suzane Silbert; Carly Kubasek; Dominic Uy; Raymond Widen
Journal:  J Clin Microbiol       Date:  2014-04-23       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.