Literature DB >> 19746455

Evaluation of the hepatic artery anastomosis by intraoperative sonography with high-frequency transducer in right-lobe graft living donor liver transplantation.

Han Song Mun1, Kyoung Won Kim, Gi-Won Song, Chul-Soo Ahn, So Yeon Kim, Shin Hwang, Sung Gyu Lee.   

Abstract

OBJECTIVE: To describe the usefulness of intraoperative ultrasonography (IOUS) with high-frequency transducer in living donor liver transplantation (LDLT) using right-lobe graft (RLG).
METHOD: This retrospective study was approved by our institutional review board. We performed IOUS in 22 patients (17 men and 5 women, aged 51 +/- 9.0 years) during LDLT with RLG using a Sequoia 512 scanner with an 8-12-MHz linear transducer. Hepatic artery (HA) anastomosis was identified on gray-scale US, and the diameter and percentage of stenosis of the anastomosis were measured. The HA was evaluated to detect thrombus or dissection in the region of anastomosis. Doppler study of the graft HA was also performed. Patients were divided into those with and without abnormalities, including thrombosis, dissection, and abnormal Doppler parameters (peak systolic velocity < 30 cm/s or > 2 m/s, resistance index < 0.5, and systolic acceleration time > 80 msec). RESULT: On gray-scale and Doppler IOUS study, abnormalities were found in 10 of 22 patients. Diagnoses were anastomotic stenosis (n = 2), celiac stenosis (n = 1), compromise of HA inflow due to systemic hypotension (n = 1), HA thrombosis (n = 2), and HA dissection (n = 4). Re-anastomoses were done in 3 case (2 stenoses and 1 thrombosis). Uneventful postoperative recovery occurred in the other 7 patients without re-anastomosis.
CONCLUSION: IOUS with high-frequency transducer is a useful method to make an early diagnosis of HA complications of LDLT with RLG. (c) 2009 Wiley Periodicals, Inc. J Clin Ultrasound, 2010.

Entities:  

Mesh:

Year:  2010        PMID: 19746455     DOI: 10.1002/jcu.20628

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  3 in total

Review 1.  Intraoperative Doppler sonogram in pediatric liver transplants: a pictorial review of intraoperative and early postoperative complications.

Authors:  A Luana Stanescu; Shawn E Kamps; André A S Dick; Marguerite T Parisi; Grace S Phillips
Journal:  Pediatr Radiol       Date:  2017-12-22

2.  Doppler ultrasonography in liver transplant recipients with hepatic artery dissection: association of Doppler abnormalities with disease severity.

Authors:  So Yeong Jeong; Kyoung Won Kim; Jin Sil Kim; Sunyoung Lee; So Yeon Kim; Gi Won Song; Sung Gyu Lee
Journal:  Br J Radiol       Date:  2018-05-23       Impact factor: 3.039

3.  Evaluation of Pediatric Liver Transplantation-Related Artery Complications Using Intra-Operative Multi-Parameter Ultrasonography.

Authors:  Xiuyun Ren; Junhui Guan; Nong Gao; Hong Niu; Jie Tang
Journal:  Med Sci Monit       Date:  2016-11-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.