Literature DB >> 19744966

Balloon expandable stent implantation for native and recurrent coarctation of the aorta--prospective computed tomography assessment of stent integrity, aneurysm formation and stenosis relief.

Santabhanu Chakrabarti1, Damien Kenny, Gareth Morgan, Stephanie L Curtis, Mark C K Hamilton, Peter Wilde, Andrew J Tometzki, Mark S Turner, Robin P Martin.   

Abstract

BACKGROUND: Stenting for aortic coarctation is known to be effective in the medium term. Aneurysm formation following stent implantation is a recognised complication. However, data regarding aortic wall injury and stent integrity following stent placement are sparse.
OBJECTIVES: We report comprehensive clinical, echocardiographic and prospective CT follow-up data following stenting for aortic coarctation from a single centre. Methods Full data analysis of all patients undergoing balloon expandable stent implantation and follow-up procedures in a single tertiary congenital cardiac unit.
RESULTS: Between October 2002 and April 2008, we performed 102 coarctation stent procedures on 88 patients. Median age was 20.6 years (range 8.5-65) and median weight 65 kg (range 34-101). 94 stents (26 covered) were implanted. 12 procedures were re-dilatations. Stenting resulted in a reduction of the gradient across the site of coarctation, from a median of 20 mm Hg to 4 mm Hg. There were no procedure-related deaths. Four patients had immediate complications (one requiring emergency surgery). During median follow-up of 34.5 months (range 4.2-72.8), two patients had late complications requiring additional stent procedures. Follow-up CT data are available in 84 patients with MRI in one patient (96.5%). Only one patient developed a procedure-related aortic aneurysm. All stent fractures (n=7) occurred with a single stent design.
CONCLUSIONS: Stenting for aortic coarctation and re-coarctation is effective with low immediate complication rates. CT is useful in the longer term for assessment of stent integrity and post-procedural aneurysm formation. Overall incidence of post-procedural aneurysm is rare and stent fractures were not seen with newer generation stents.

Entities:  

Mesh:

Year:  2009        PMID: 19744966     DOI: 10.1136/hrt.2009.170928

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  15 in total

Review 1.  Compression, distortion and dislodgement of large caliber stents in congenital heart defects caused by cardiopulmonary resuscitation: a case series and review of the literature.

Authors:  Nikolaus A Haas; Christoph M Happel; Smita Jategaonkar; Axel Moysich; Andreas Hanslik; Deniz Kececioglu; Eugen Sandica; Kai Thorsten Laser
Journal:  Clin Res Cardiol       Date:  2014-04-04       Impact factor: 5.460

2.  Using the Valeo dilatable stent in coarctation stenting for small children: expanding the inclusion criteria for coarctation stenting?

Authors:  Emma Shepherd; Georgia May Connolly; Gareth Morgan
Journal:  BMJ Case Rep       Date:  2013-12-11

3.  Prevalence and long-term predictors of left ventricular hypertrophy, late hypertension, and hypertensive response to exercise after successful aortic coarctation repair.

Authors:  Arianna Bocelli; Silvia Favilli; Iva Pollini; Roberta Margherita Bini; Piercarlo Ballo; Enrico Chiappa; Alfredo Zuppiroli
Journal:  Pediatr Cardiol       Date:  2012-09-30       Impact factor: 1.655

4.  Stent Therapy for Aortic Coarctation in Children <30 kg: Use of the Low Profile Valeo Stent.

Authors:  Sok-Leng Kang; Andrew Tometzki; Demetris Taliotis; Robin Martin
Journal:  Pediatr Cardiol       Date:  2017-08-05       Impact factor: 1.655

Review 5.  Imaging of patients with congenital heart disease.

Authors:  Arno A W Roest; Albert de Roos
Journal:  Nat Rev Cardiol       Date:  2011-11-01       Impact factor: 32.419

Review 6.  Coarctation repair-redo challenges in the adults: what to do?

Authors:  Erik Beckmann; Arminder S Jassar
Journal:  J Vis Surg       Date:  2018-04-23

7.  Results of screening for intracranial aneurysms in patients with coarctation of the aorta.

Authors:  S L Curtis; M Bradley; P Wilde; J Aw; S Chakrabarti; M Hamilton; R Martin; M Turner; A G Stuart
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-09       Impact factor: 3.825

Review 8.  Covered Stents in the Management of Aortic Coarctation and Right Ventricular Outflow Tract Obstruction.

Authors:  Nibras E El Sherif; Nathaniel W Taggart
Journal:  Curr Cardiol Rep       Date:  2022-01-13       Impact factor: 2.931

9.  Medium and long-term outcomes after bilateral pulmonary artery stenting in children and adults with congenital heart disease.

Authors:  Ismael Gonzalez; Damien Kenny; Shari Slyder; Ziyad M Hijazi
Journal:  Pediatr Cardiol       Date:  2012-07-28       Impact factor: 1.655

10.  Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

Authors:  A M den Harder; D Suchá; R W van Hamersvelt; R P J Budde; P A de Jong; A M R Schilham; C Bos; J M P J Breur; T Leiner
Journal:  PLoS One       Date:  2017-01-31       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.