PURPOSE: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement.
MATERIAL AND METHODS: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations in full occlusion. Definitive metal ceramic restorations were fabricated and positioned on each implant after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 24 months after implant placement.
RESULTS: Of the 89 inserted implants, two (2.2%) implants failed to integrate and were removed during healing, and two (2.2%) additional implants required a prolonged healing time. A total of 85 (95.6%) implants were therefore loaded without incident after 21 days of healing. No additional implant was lost throughout the study period, whereas one implant was lost to follow-up and therefore left unaccounted for further analysis. The remaining 86 implants all exhibited favorable radiographic and clinical findings. Based on strict success criteria, these implants were considered successfully integrated 2 years after insertion, resulting in a 2-year success rate of 97.7%.
CONCLUSION: The results of this prospective two-center study demonstrate that titanium implants with a modified SLA surface can predictably achieve successful tissue integration when loaded in full occlusion 21 days after placement. Integration could be maintained without incident for at least 2 years of follow-up.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19744195     DOI: 10.1111/j.1708-8208.2009.00204.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  11 in total

Review 1.  A review on the wettability of dental implant surfaces II: Biological and clinical aspects.

Authors:  Rolando A Gittens; Lutz Scheideler; Frank Rupp; Sharon L Hyzy; Jürgen Geis-Gerstorfer; Zvi Schwartz; Barbara D Boyan
Journal:  Acta Biomater       Date:  2014-04-05       Impact factor: 8.947

2.  The effect of fibronectin-coated implant on canine osseointegration.

Authors:  Sungtae Kim; Woo-Chun Myung; Jung-Seok Lee; Jae-Kook Cha; Ui-Won Jung; Hyeong-Cheol Yang; In-Seop Lee; Seong-Ho Choi
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

Review 3.  Impact of Dental Implant Surface Modifications on Osseointegration.

Authors:  Ralf Smeets; Bernd Stadlinger; Frank Schwarz; Benedicta Beck-Broichsitter; Ole Jung; Clarissa Precht; Frank Kloss; Alexander Gröbe; Max Heiland; Tobias Ebker
Journal:  Biomed Res Int       Date:  2016-07-11       Impact factor: 3.411

4.  A randomized, 12-month controlled trial to evaluate non-inferiority of early compared to conventional loading of modSLA implants in single tooth gaps.

Authors:  Michel Dard; Makoto Shiota; Minoru Sanda; Yasutomo Yajima; Hideshi Sekine; Shohei Kasugai
Journal:  Int J Implant Dent       Date:  2016-04-04

5.  Nano-Pore Size of Alumina Affects Osteoblastic Response.

Authors:  Federico Mussano; Tullio Genova; Francesca Giulia Serra; Massimo Carossa; Luca Munaron; Stefano Carossa
Journal:  Int J Mol Sci       Date:  2018-02-09       Impact factor: 5.923

6.  An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis.

Authors:  Arkadiusz Makowiecki; Jakub Hadzik; Artur Błaszczyszyn; Tomasz Gedrange; Marzena Dominiak
Journal:  BMC Oral Health       Date:  2019-05-10       Impact factor: 2.757

7.  Microscopic Characterization of Bioactivate Implant Surfaces: Increasing Wettability Using Salts and Dry Technology.

Authors:  Francesco Gianfreda; Donato Antonacci; Carlo Raffone; Maurizio Muzzi; Valeria Pistilli; Patrizio Bollero
Journal:  Materials (Basel)       Date:  2021-05-17       Impact factor: 3.623

8.  Current knowledge about the hydrophilic and nanostructured SLActive surface.

Authors:  Ann Wennerberg; Silvia Galli; Tomas Albrektsson
Journal:  Clin Cosmet Investig Dent       Date:  2011-09-05

9.  A comparative in vivo study of strontium-functionalized and SLActive™ implant surfaces in early bone healing.

Authors:  Vincent Offermanns; Ole Z Andersen; Michael Sillassen; Klaus P Almtoft; Inge H Andersen; Frank Kloss; Morten Foss
Journal:  Int J Nanomedicine       Date:  2018-04-11

10.  Bioactive characteristics of an implant surface coated with a pH buffering agent: an in vitro study.

Authors:  Hyung-Chul Pae; Su-Kyoung Kim; Jin-Young Park; Young Woo Song; Jae-Kook Cha; Jeong-Won Paik; Seong-Ho Choi
Journal:  J Periodontal Implant Sci       Date:  2019-11-04       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.