Literature DB >> 19743873

Non-trilinear chromatographic time retention-fluorescence emission data coupled to chemometric algorithms for the simultaneous determination of 10 polycyclic aromatic hydrocarbons in the presence of interferences.

Santiago A Bortolato1, Juan A Arancibia, Graciela M Escandar.   

Abstract

Multivariate calibration coupled to high-performance liquid chromatography-fast scanning fluorescence spectroscopy (HPLC-FSFS) was employed for the analysis of 10 selected polycyclic aromatic hydrocarbons (PAHs), six of which correspond to heavy PAHs. The goal of the present study was the successful resolution of a system even in the presence of real interferences. Second-order HPLC-FSFS data matrices were obtained in a short time with a chromatographic system operating in isocratic mode. The difficulties in aligning chromatographic bands in complex systems, such as the ones presented here, are discussed. Two second-order calibration algorithms which do not require chromatographic alignment were selected for data processing, namely, multivariate curve resolution-alternating least-squares (MCR-ALS) and parallel factor analysis 2 (PARAFAC2). These algorithms did also achieve the second-order advantage, and therefore they were able to overcome the problem of the presence of unexpected interferences. The study was employed for the discussion of the scopes of the applied second-order chemometric tools, demonstrating the superiority of MCR-ALS to successfully resolve this complex system. The quality of the proposed techniques was assessed on the basis of the analytical recoveries from different types of water and olive oil samples after solid-phase extraction. The studied concentration ranges in water samples were 5.6 x 10(-3)-0.20 ng mL(-1) for heavy PAHs and 0.036-0.80 ng mL(-1) for light PAHs, while in oil samples the PAHs concentrations were 0.13-9.6 and 2.3-49.5 ng mL(-1) for heavy and light PAHS, respectively. All real samples were analyzed in the presence of the studied interferences.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19743873     DOI: 10.1021/ac901272b

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Applications of phasors to in vitro time-resolved fluorescence measurements.

Authors:  Martin Stefl; Nicholas G James; Justin A Ross; David M Jameson
Journal:  Anal Biochem       Date:  2010-11-13       Impact factor: 3.365

2.  Amino acid-functionalized carbon quantum dots for selective detection of Al3+ ions and fluorescence imaging in living cells.

Authors:  Chaoren Yan; Liulong Guo; Xu Shao; Qi Shu; Ping Guan; Jingwei Wang; Xiaoling Hu; Chaoli Wang
Journal:  Anal Bioanal Chem       Date:  2021-04-28       Impact factor: 4.142

3.  Determination of high-molecular weight polycyclic aromatic hydrocarbons in high performance liquid chromatography fractions of coal tar standard reference material 1597a via solid-phase nanoextraction and laser-excited time-resolved Shpol'skii spectroscopy.

Authors:  Walter B Wilson; Bassam Alfarhani; Anthony F T Moore; Cristina Bisson; Stephen A Wise; Andres D Campiglia
Journal:  Talanta       Date:  2015-11-10       Impact factor: 6.057

4.  Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods.

Authors:  Shiva Ghafghazi; Taraneh Moini Zanjani; Maryam Vosough; Masoumeh Sabetkasaei
Journal:  Iran J Pharm Res       Date:  2017       Impact factor: 1.696

5.  Flexible Implementation of the Trilinearity Constraint in Multivariate Curve Resolution Alternating Least Squares (MCR-ALS) of Chromatographic and Other Type of Data.

Authors:  Xin Zhang; Romà Tauler
Journal:  Molecules       Date:  2022-04-05       Impact factor: 4.411

  5 in total