Lun Wang1, Bo Ling, Hongqi Chen, Ani Liang, Binbin Qian, Jie Fu.
Abstract
A novel chemiluminescence method for the determination of 6-mercaptopurine was established based on 6-mercaptopurine inhibition of the chemiluminescence emission of potassium permanganate-thioacetamide-sodium hexametaphosphate system. The peak height was proportional to log 6-mercaptopurine concentration in the range 7.0 × 10(-10) to 1.0 × 10(-7) g/mL and the detection limit was 1.9 × 10(-11) g/mL (S/N = 3). The relative standard deviation was 1.5% for the determination of 8.0 × 10(-8) g/mL 6-mercaptopurine (n = 11). The proposed sensor was successfully applied to the analysis of 6-mercaptopurine in human serum samples.Entities:
Mesh:
Substances:
Year: 2009 PMID: 19743527 DOI: 10.1002/bio.1171