Literature DB >> 19743488

Long-term clinical outcomes after angiographically defined very late stent thrombosis of drug-eluting stent.

Ung Kim1, Dong-Kie Kim, Young-Bok Kim, Sang-Hoon Seol, Tae-Hyun Yang, Dae-Kyeong Kim, Doo-Il Kim, Dong-Soo Kim, Sang-Hee Lee, Geu-Ru Hong, Jong-Seon Park, Dong-Gu Shin, Young-Jo Kim, Yoon-Kyung Cho, Hyung-Seop Kim, Chang-Wook Nam, Seung-Ho Hur, Kwon-Bae Kim.   

Abstract

BACKGROUND: The advent of drug-eluting stent (DES) use has raised concerns regarding later occurring stent thrombosis, especially very late stent thrombosis (VLST), and little is known about long-term clinical outcomes after VLST occurrence. HYPOTHESIS: Long-term clinical outcomes after detection of VLST may be poor.
METHOD: We evaluated 3572 consecutive patients who received DES implantation from May 2004 to July 2007 at 3 hospitals. The primary outcomes were a composite of major adverse cardiac events (MACE) including cardiac death, myocardial infarction (MI), target-lesion revascularization (TLR), and target-vessel revascularization (TVR) after VLST occurrence.
RESULTS: We identified 19 patients (0.53%) with angiographically documented stent thrombosis developing over 1 year after DES implantation. The mean time to VLST occurrence was 899 days (899 +/- 353). Discontinuation of antiplatelet drugs was noted in 4 (21%) patients and the average duration of discontinuation was 4 days. Clinical presentations of VLST were mainly MI (17 patients, 89%). Balloon angioplasty was only performed in 12 patients (63%) and stent implantation in 7 patients (37%). Mean follow-up duration from VLST occurrence was 620 days (620+/-256). During clinical follow-up after VLST occurrence, no cardiac deaths or MIs were detected. Target-vessel revascularization was done in 2 (11%) patients and TLR in 1 patient (6%). Major adverse cardiac events occurred in 3 (16%) patients during long-term clinical follow-up.
CONCLUSIONS: Clinical presentation of VLST after DES implantation is associated with serious adverse events, such as MI. Long-term follow-up outcomes after VLST occurrence appear unfavorable and more data from larger studies are warranted. Copyright 2009 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19743488      PMCID: PMC6653117          DOI: 10.1002/clc.20648

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882


  10 in total

Review 1.  Coronary-artery stents.

Authors:  Patrick W Serruys; Michael J B Kutryk; Andrew T L Ong
Journal:  N Engl J Med       Date:  2006-02-02       Impact factor: 91.245

Review 2.  Late coronary stent thrombosis.

Authors:  Stephan Windecker; Bernhard Meier
Journal:  Circulation       Date:  2007-10-23       Impact factor: 29.690

3.  Clinical end points in coronary stent trials: a case for standardized definitions.

Authors:  Donald E Cutlip; Stephan Windecker; Roxana Mehran; Ashley Boam; David J Cohen; Gerrit-Anne van Es; P Gabriel Steg; Marie-angèle Morel; Laura Mauri; Pascal Vranckx; Eugene McFadden; Alexandra Lansky; Martial Hamon; Mitchell W Krucoff; Patrick W Serruys
Journal:  Circulation       Date:  2007-05-01       Impact factor: 29.690

4.  Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation.

Authors:  Stéphane Cook; Peter Wenaweser; Mario Togni; Michael Billinger; Cyrill Morger; Christian Seiler; Rolf Vogel; Otto Hess; Bernhard Meier; Stephan Windecker
Journal:  Circulation       Date:  2007-05-08       Impact factor: 29.690

5.  Incidence and correlates of drug-eluting stent thrombosis in routine clinical practice. 4-year results from a large 2-institutional cohort study.

Authors:  Peter Wenaweser; Joost Daemen; Marcel Zwahlen; Ron van Domburg; Peter Jüni; Sophia Vaina; Gerrit Hellige; Keiichi Tsuchida; Cyrill Morger; Eric Boersma; Neville Kukreja; Bernhard Meier; Patrick W Serruys; Stephan Windecker
Journal:  J Am Coll Cardiol       Date:  2008-09-30       Impact factor: 24.094

6.  Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents.

Authors:  Adnan Kastrati; Julinda Mehilli; Jürgen Pache; Christoph Kaiser; Marco Valgimigli; Henning Kelbaek; Maurizio Menichelli; Manel Sabaté; Maarten J Suttorp; Dietrich Baumgart; Melchior Seyfarth; Matthias E Pfisterer; Albert Schömig
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

7.  Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents.

Authors:  Gregg W Stone; Jeffrey W Moses; Stephen G Ellis; Joachim Schofer; Keith D Dawkins; Marie-Claude Morice; Antonio Colombo; Erick Schampaert; Eberhard Grube; Ajay J Kirtane; Donald E Cutlip; Martin Fahy; Stuart J Pocock; Roxana Mehran; Martin B Leon
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

8.  Long-term clinical outcome after a first angiographically confirmed coronary stent thrombosis: an analysis of 431 cases.

Authors:  Jochem W van Werkum; Antonius A C M Heestermans; Fleur I de Korte; Johannes C Kelder; Maarten-Jan Suttorp; Benno J W M Rensing; Bastiaan Zwart; B R Guus Brueren; Jacques J Koolen; Jan-Henk E Dambrink; Arnoud W J van't Hof; Freek W A Verheugt; Jurriën M ten Berg
Journal:  Circulation       Date:  2009-02-02       Impact factor: 29.690

Review 9.  Coronary artery stents: a rapid systematic review and economic evaluation.

Authors:  R Hill; A Bagust; A Bakhai; R Dickson; Y Dündar; A Haycox; R Mujica Mota; A Reaney; D Roberts; P Williamson; T Walley
Journal:  Health Technol Assess       Date:  2004-09       Impact factor: 4.014

Review 10.  Vascular pathology of drug-eluting stents.

Authors:  Gaku Nakazawa; Aloke V Finn; Renu Virmani
Journal:  Herz       Date:  2007-06       Impact factor: 1.443

  10 in total
  1 in total

1.  Domestic versus imported drug-eluting stents for the treatment of patients with acute coronary syndrome.

Authors:  Hai-Mu Yao; Tong-Wen Sun; You-Dong Wan; Xiao-Juan Zhang; Xin Fu; De-Liang Shen; Jin-Ying Zhang; Ling Li
Journal:  World J Emerg Med       Date:  2014
  1 in total