Locating illicit connections in storm water sewers using fiber-optic distributed temperature sensing.

O A C Hoes1, R P S Schilperoort, W M J Luxemburg, F H L R Clemens, N C van de Giesen.   

Abstract

A newly developed technique using distributed temperature sensing (DTS) has been developed to find illicit household sewage connections to storm water systems in the Netherlands. DTS allows for the accurate measurement of temperature along a fiber-optic cable, with high spatial (2m) and temporal (30s) resolution. We inserted a fiber-optic cable of 1300m in two storm water drains. At certain locations, significant temperature differences with an intermittent character were measured, indicating inflow of water that was not storm water. In all cases, we found that foul water from households or companies entered the storm water system through an illicit sewage connection. The method of using temperature differences for illicit connection detection in storm water networks is discussed. The technique of using fiber-optic cables for distributed temperature sensing is explained in detail. The DTS method is a reliable, inexpensive and practically feasible method to detect illicit connections to storm water systems, which does not require access to private property.

Entities:  

Mesh:

Year:  2009        PMID: 19735929     DOI: 10.1016/j.watres.2009.08.020

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  5 in total

1.  Event mean concentration and first flush effect from different drainage systems and functional areas during storms.

Authors:  Hai-Qin Peng; Yan Liu; Hong-Wu Wang; Xue-Long Gao; Lu-Ming Ma
Journal:  Environ Sci Pollut Res Int       Date:  2015-11-13       Impact factor: 4.223

2.  Double-ended calibration of fiber-optic Raman spectra distributed temperature sensing data.

Authors:  Nick van de Giesen; Susan C Steele-Dunne; Jop Jansen; Olivier Hoes; Mark B Hausner; Scott Tyler; John Selker
Journal:  Sensors (Basel)       Date:  2012-04-27       Impact factor: 3.576

3.  A Low-Cost Water Depth and Electrical Conductivity Sensor for Detecting Inputs into Urban Stormwater Networks.

Authors:  Baiqian Shi; Stephen Catsamas; Peter Kolotelo; Miao Wang; Anna Lintern; Dusan Jovanovic; Peter M Bach; Ana Deletic; David T McCarthy
Journal:  Sensors (Basel)       Date:  2021-04-27       Impact factor: 3.576

4.  Identifying and Estimating the Location of Sources of Industrial Pollution in the Sewage Network.

Authors:  Magdalena Paulina Buras; Fernando Solano Donado
Journal:  Sensors (Basel)       Date:  2021-05-14       Impact factor: 3.576

5.  Robust sensing suite for measuring temporal dynamics of surface temperature in sewers.

Authors:  Karthick Thiyagarajan; Sarath Kodagoda; Ravindra Ranasinghe; Dammika Vitanage; Gino Iori
Journal:  Sci Rep       Date:  2018-10-30       Impact factor: 4.379