Single-beat estimation of the left ventricular end-systolic pressure-volume relationship in patients with heart failure.

E A ten Brinke1, R J Klautz, H F Verwey, E E van der Wall, R A Dion, P Steendijk.   

Abstract

AIM: The end-systolic pressure-volume relationship (ESPVR) constructed from multiple pressure-volume (PV) loops acquired during load intervention is an established method to asses left ventricular (LV) contractility. We tested the accuracy of simplified single-beat (SB) ESPVR estimation in patients with severe heart failure.
METHODS: Nineteen heart failure patients (NYHA III-IV) scheduled for surgical ventricular restoration and/or restrictive mitral annuloplasty and 12 patients with normal LV function scheduled for coronary artery bypass grafting were included. PV signals were obtained before and after cardiac surgery by pressure-conductance catheters and gradual pre-load reductions by vena cava occlusion (VCO). The SB method was applied to the first beat of the VCO run. Accuracy was quantified by the root-mean-square-error (RMSE) between ESPVR(SB) and gold-standard ESPVR(VCO). In addition, we compared slopes (E(ES)) and intercepts (end-systolic volume at multiple pressure levels (70-100 mmHg: ESV(70)-ESV(100)) of ESPVR(SB) vs. ESPVR(VCO) by Bland-Altman analyses.
RESULTS: RMSE was 1.7 + or - 1.0 mmHg and was not significantly different between groups and not dependent on end-diastolic volume, indicating equal, high accuracy over a wide volume range. SB-predicted E(ES) had a bias of -0.39 mmHg mL(-1) and limits of agreement (LoA) -2.0 to +1.2 mmHg mL(-1). SB-predicted ESVs at each pressure level showed small bias (range: -10.8 to +9.4 mL) and narrow LoA. Two-way anova indicated that differences between groups were not dependent on the method.
CONCLUSION: Our findings, obtained in hearts spanning a wide range of sizes and conditions, support the use of the SB method. This method ultimately facilitates less invasive ESPVR estimation, particularly when coupled with emerging noninvasive techniques to measure LV pressures and volumes.

Entities:  

Mesh:

Year:  2009        PMID: 19735484     DOI: 10.1111/j.1748-1716.2009.02040.x

Source DB:  PubMed          Journal:  Acta Physiol (Oxf)        ISSN: 1748-1708            Impact factor:   6.311


  14 in total

1.  Inefficient Ventriculoarterial Coupling in Fontan Patients: A Cardiac Magnetic Resonance Study.

Authors:  Max E Godfrey; Rahul H Rathod; Ellen Keenan; Kimberlee Gauvreau; Andrew J Powell; Tal Geva; Ashwin Prakash
Journal:  Pediatr Cardiol       Date:  2018-02-05       Impact factor: 1.655

2.  Intermittent Occlusion of the Superior Vena Cava Reduces Cardiac Filling Pressures in Preclinical Models of Heart Failure.

Authors:  Navin K Kapur; Lara Reyelt; Paige Crowley; Lauren Richey; John McCarthy; Shiva Annamalai; Sarah Newman; Lena Jorde; Sina Forotuanjazi; Allen Razavi; Tim Lenihan; Daniel Burkhoff; Richard H Karas
Journal:  J Cardiovasc Transl Res       Date:  2019-11-26       Impact factor: 4.132

3.  Algorithmic processing of pressure waveforms to facilitate estimation of cardiac elastance.

Authors:  David Stevenson; James Revie; J Geoffrey Chase; Christopher E Hann; Geoffrey M Shaw; Bernard Lambermont; Alexandre Ghuysen; Philippe Kolh; Thomas Desaive
Journal:  Biomed Eng Online       Date:  2012-06-15       Impact factor: 2.819

4.  Invasive Right Ventricular Pressure-Volume Analysis: Basic Principles, Clinical Applications, and Practical Recommendations.

Authors:  Michael I Brener; Amirali Masoumi; Vivian G Ng; Khodr Tello; Marcelo B Bastos; William K Cornwell; Steven Hsu; Ryan J Tedford; Philipp Lurz; Karl-Philipp Rommel; Karl-Patrik Kresoja; Sherif F Nagueh; Manreet K Kanwar; Navin K Kapur; Gurumurthy Hiremath; Mohammad Sarraf; Antoon J M Van Den Enden; Nicolas M Van Mieghem; Paul M Heerdt; Rebecca T Hahn; Susheel K Kodali; Gabriel T Sayer; Nir Uriel; Daniel Burkhoff
Journal:  Circ Heart Fail       Date:  2021-12-29       Impact factor: 8.790

Review 5.  Methods for measuring right ventricular function and hemodynamic coupling with the pulmonary vasculature.

Authors:  Alessandro Bellofiore; Naomi C Chesler
Journal:  Ann Biomed Eng       Date:  2013-02-20       Impact factor: 3.934

6.  Ventricular pressure-volume loops obtained by 3D real-time echocardiography and mini pressure wire-a feasibility study.

Authors:  Ulrike Herberg; Eva Gatzweiler; Thomas Breuer; Johannes Breuer
Journal:  Clin Res Cardiol       Date:  2013-02-09       Impact factor: 5.460

7.  CaMKII activity contributes to homeometric autoregulation of the heart: A novel mechanism for the Anrep effect.

Authors:  Jan-Christian Reil; Gert-Hinrich Reil; Árpád Kovács; Vasco Sequeira; Mark T Waddingham; Maria Lodi; Melissa Herwig; Shahrooz Ghaderi; Michael M Kreusser; Zoltán Papp; Niels Voigt; Dobromir Dobrev; Svenja Meyhöfer; Harald F Langer; Lars S Maier; Dominik Linz; Andreas Mügge; Mathias Hohl; Paul Steendijk; Nazha Hamdani
Journal:  J Physiol       Date:  2020-06-14       Impact factor: 5.182

8.  Echocardiographic Detection of Increased Ventricular Diastolic Stiffness in Pediatric Heart Transplant Recipients: A Pilot Study.

Authors:  Shahryar M Chowdhury; Ryan J Butts; Anthony M Hlavacek; Carolyn L Taylor; Karen S Chessa; Varsha M Bandisode; Girish S Shirali; Arni Nutting; G Hamilton Baker
Journal:  J Am Soc Echocardiogr       Date:  2017-12-13       Impact factor: 5.251

9.  Beat-to-beat estimation of the continuous left and right cardiac elastance from metrics commonly available in clinical settings.

Authors:  David Stevenson; James Revie; J Geoffrey Chase; Christopher E Hann; Geoffrey M Shaw; Bernard Lambermont; Alexandre Ghuysen; Philippe Kolh; Thomas Desaive
Journal:  Biomed Eng Online       Date:  2012-09-21       Impact factor: 2.819

10.  End-systolic Pressure-Volume Relation, Ejection Fraction, and Heart Failure: Theoretical Aspect and Clinical Applications.

Authors:  Rachad M Shoucri
Journal:  Clin Med Insights Cardiol       Date:  2015-07-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.