Literature DB >> 19735404

A comparison of the i-gel with the LMA-Unique in non-paralysed anaesthetised adult patients.

H Francksen1, J Renner, R Hanss, J Scholz, V Doerges, B Bein.   

Abstract

SUMMARY: This study assessed two disposable devices; the newly developed supraglottic airway device i-gel and the LMA-Unique in routine clinical practice. Eighty patients (ASA 1-3) undergoing minor routine gynaecologic surgery were randomly allocated to have an i-gel (n = 40) or LMA-Unique (n = 40) inserted. Oxygen saturation, end-tidal carbon dioxide, tidal volume and peak airway pressure were recorded, as well as time of insertion, airway leak pressure, postoperative sore-throat, dysphonia and dysphagia for each device. Time of insertion was comparable with the i-gel and LMA-Unique. There was no failure in the i-gel group and one failure in the LMA-Unique group. Ventilation and oxygenation were similar between devices. Mean airway pressure was comparable with both devices, whereas airway leak pressure was significantly higher (p < 0.0001) in the i-gel group (mean 29 cmH(2)O, range 24-40) compared with the LMA-Unique group (mean 18 cmH(2)O, range 6-30). Fibreoptic score of the position of the devices was significantly better in the i-gel group. Post-operative sore-throat and dysphagia were comparable with both devices. Both devices appeared to be simple alternatives to secure the airway. Significantly higher airway leak pressure suggests that the i-gel may be advantageous in this respect.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19735404     DOI: 10.1111/j.1365-2044.2009.06017.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  19 in total

1.  General anesthesia improves contact force and reduces gap formation in pulmonary vein isolation: a comparison with conscious sedation.

Authors:  Akio Chikata; Takeshi Kato; Takanori Yaegashi; Satoru Sakagami; Chieko Kato; Takahiro Saeki; Keiichi Kawai; Shin-Ichiro Takashima; Hisayoshi Murai; Soichiro Usui; Hiroshi Furusho; Shuichi Kaneko; Masayuki Takamura
Journal:  Heart Vessels       Date:  2017-03-04       Impact factor: 2.037

2.  A randomized comparison of the i-gel and the ProSeal laryngeal mask airway in pediatric patients: performance and fiberoptic findings.

Authors:  Aya Fukuhara; Ryu Okutani; Yutaka Oda
Journal:  J Anesth       Date:  2012-09-11       Impact factor: 2.078

3.  Comparison of Laryngeal Mask Airway Supreme(TM) Versus Unique(TM) in Edentulous Geriatric Patients.

Authors:  Tangül Beydeş; Semih Küçükgüçlü; Şule Özbilgin; Bahar Kuvaki; Meltem Ademoğlu; Melek Sarı
Journal:  Turk J Anaesthesiol Reanim       Date:  2016-02-01

4.  Comparison of Four Different Supraglottic Airway Devices in Terms of Efficacy, Intra-ocular Pressure and Haemodynamic Parameters in Children Undergoing Ophthalmic Surgery.

Authors:  Gökhan Peker; Suna Akın Takmaz; Bülent Baltacı; Hülya Başar; Mustafa Kotanoğlu
Journal:  Turk J Anaesthesiol Reanim       Date:  2015-08-21

5.  Clinical Comparison of I-Gel Supraglottic Airway Device and Cuffed Endotracheal Tube for Pressure-Controlled Ventilation During Routine Surgical Procedures.

Authors:  Ankur Dhanda; Shalendra Singh; Anju R Bhalotra; Siddharth Chavali
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-10-01

6.  Comparison of three supraglottic devices in anesthetised paralyzed children undergoing elective surgery.

Authors:  Bikramjit Das; Subhro Mitra; Shahin N Jamil; Rohit K Varshney
Journal:  Saudi J Anaesth       Date:  2012-07

7.  Comparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopy.

Authors:  Woo Jae Jeon; Sang Yun Cho; Seong Jin Baek; Kyoung Hun Kim
Journal:  Korean J Anesthesiol       Date:  2012-12-14

8.  Comparative study between I-gel, a new supraglottic airway device, and classical laryngeal mask airway in anesthetized spontaneously ventilated patients.

Authors:  Amr M Helmy; Hossam M Atef; Ezzat M El-Taher; Ahmed Mosaad Henidak
Journal:  Saudi J Anaesth       Date:  2010-09

9.  Comparison of Size 2.5 i-gel™ with Proseal LMA™ in Anaesthetised, Paralyzed Children Undergoing Elective Surgery.

Authors:  Subhro Mitra; Bikramjit Das; Shahin N Jamil
Journal:  N Am J Med Sci       Date:  2012-10

10.  Comparison of i-gel supraglottic airway and LMA-ProSeal™ in pediatric patients under controlled ventilation.

Authors:  Sai Saran; Sandeep Kumar Mishra; Ashok Shankar Badhe; Arumugam Vasudevan; Lenin Babu Elakkumanan; Gayatri Mishra
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-04
View more