Literature DB >> 19733725

Effect of transcatheter pulmonary valve implantation on short-term right ventricular function as determined by two-dimensional speckle tracking strain and strain rate imaging.

Nasser Moiduddin1, Kentaro Asoh, Cameron Slorach, Leland N Benson, Mark K Friedberg.   

Abstract

Transcatheter pulmonary valve implantation (PVI) is an emerging therapy for right ventricular (RV) outflow dysfunction in congenital heart disease. We investigated, for the first time in children after surgery for congenital heart disease, the short-term effects of PVI on RV and left ventricular (LV) function using 2-dimensional speckle tracking echocardiography and tissue Doppler imaging. We hypothesized that the short-term RV and LV function would improve. Two-dimensional speckle tracking echocardiograms and pulsed tissue Doppler images were obtained before and 1 to 2 days after PVI (18-mm Melody valve). The catheter right heart hemodynamics were recorded. The strain and strain rate of the basal lateral left ventricle, lateral right ventricle, and interventricular septum were measured by 2-dimensional speckle tracking echo, and the pre- and postprocedure values were compared. Of the 16 eligible patients (age 16 +/- 2 years), the scans of 10 had correct image format and adequate quality. PVI was performed for volume (n = 4) or combined pressure-volume (n = 6) loading. After PVI, the RV to pulmonary artery pressure gradient (33 +/- 22 to 12 +/- 4 mm Hg, p = 0.02), pulmonary regurgitation, and RV end-diastolic volume (3.2 +/- 0.8 to 2.8 +/- 0.6 cm, p = 0.02) decreased, and the septal systolic velocities (3.5 +/- 1.1 to 4.7 +/- 1.1 cm/s, p = 0.04), strain (-7.6 +/- 9.3% to -15.6% +/- 6.7%, p = 0.01) and strain rate (-0.3 +/- 1.1 to -1.1 +/- 0.5 1/s, p = 0.04) and RV free wall strain increased (-17.4 +/- 8.6% to -23.4% +/- 6.2%, p = 0.03). The LV tissue velocities, strain, and strain rate were unchanged. In conclusion, PVI leads to RV unloading and acutely improves RV and septal function.

Entities:  

Mesh:

Year:  2009        PMID: 19733725     DOI: 10.1016/j.amjcard.2009.05.018

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  15 in total

1.  Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial.

Authors:  Doff B McElhinney; William E Hellenbrand; Evan M Zahn; Thomas K Jones; John P Cheatham; James E Lock; Julie A Vincent
Journal:  Circulation       Date:  2010-07-19       Impact factor: 29.690

2.  Early echocardiographic changes after percutaneous implantation of the Edwards SAPIEN transcatheter heart valve in the pulmonary position.

Authors:  Shahryar M Chowdhury; Ziyad M Hijazi; John Rhodes; Saibal Kar; Raj Makkar; Michael Mullen; Qi-Ling Cao; Lydia King; Jodi Akin; Girish Shirali
Journal:  Echocardiography       Date:  2013-02-22       Impact factor: 1.724

3.  Changes in speckle tracking echocardiography measures of ventricular function after percutaneous implantation of the Edwards SAPIEN transcatheter heart valve in the pulmonary position.

Authors:  Shahryar M Chowdhury; Ziyad M Hijazi; John F Rhodes; Saibal Kar; Raj Makkar; Michael Mullen; Qi-Ling Cao; Lazar Mandinov; Jason Buckley; Nicholas P Pietris; Girish S Shirali
Journal:  Echocardiography       Date:  2014-07-22       Impact factor: 1.724

Review 4.  Will catheter interventions replace surgery for valve abnormalities?

Authors:  Michael L O'Byrne; Matthew J Gillespie
Journal:  Curr Opin Cardiol       Date:  2014-01       Impact factor: 2.161

5.  Non-Invasive Imaging for Congenital Heart Disease: Recent Innovations in Transthoracic Echocardiography.

Authors:  Martin Koestenberger; Mark K Friedberg; William Ravekes; Eirik Nestaas; Georg Hansmann
Journal:  J Clin Exp Cardiolog       Date:  2012-01-22

6.  High-frequency high-resolution echocardiography: first evidence on non-invasive repeated measure of myocardial strain, contractility, and mitral regurgitation in the ischemia-reperfused murine heart.

Authors:  Surya C Gnyawali; Sashwati Roy; Jason Driggs; Savita Khanna; Thomas Ryan; Chandan K Sen
Journal:  J Vis Exp       Date:  2010-07-09       Impact factor: 1.355

7.  Transthoracic echocardiography in children and young adults with congenital heart disease.

Authors:  Martin Koestenberger
Journal:  ISRN Pediatr       Date:  2012-06-13

Review 8.  Functional assessment for congenital heart disease.

Authors:  Yiu-Fai Cheung
Journal:  Korean Circ J       Date:  2014-03       Impact factor: 3.243

Review 9.  Advanced echocardiographic imaging of the congenitally malformed heart.

Authors:  D Black; J Vettukattil
Journal:  Curr Cardiol Rev       Date:  2013-08

10.  Increased regional deformation of the left ventricle in normal children with increased body mass index: implications for future cardiovascular health.

Authors:  David Black; Jen Bryant; Charles Peebles; Lucy Davies; Hazel Inskip; Keith Godfrey; Joseph Vettukattil; Mark Hanson
Journal:  Pediatr Cardiol       Date:  2013-08-29       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.